May 27, 2026 12 demerits · 3 violations
Inspector comments: CPO= ANTONIO SANCHEZ LOPEZ # C-078646
NIGHT SWIMMING IS NOT PERMITTED.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. OBSERVED ladders in disrepair. CDI. PIC repaired.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed body hook 3 times the size of the pool. CDI. PIC corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed under fence at more than 4’’. Needs to be filled or fixed.
Jul 1, 2025 2 demerits · 1 violation
Inspector comments: NIGHT SWIMMING NOT PERMITTED
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Observed one rubber fitting missing on ladder near 5 foot depth marker.
Jun 11, 2024 6 demerits · 1 violation
#22 · Premises: emergency telephone provided −6
.2530(f) Provide signage with location of emergency phone if not visible from all areas inside pool enclosure. Observed location of emergency phone not listed on signage and phone not visible from all areas on pool deck. CDI PIC added location of phone to pool sign.
May 19, 2023 8 demerits · 2 violations
Inspector comments: Permit issued
No night swimming
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed 3 missing weirs. CDI: weirs provided and installed.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter stuck. CDI: flow meter fixed.
Jun 23, 2022 0 demerits · 0 violations
Inspector comments: Pool passed inspection. Corrected previous issues.
No violations were recorded for this inspection.
May 23, 2019 10 demerits · 2 violations
Inspector comments: Night swimming has not been permited.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8.
Observed pH to be at 7.0. This was corrected and the pH was raised to about 7.2.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present.
Observed the gate self closing but not self latching. This was corrected and the operator was able to repair the gate to where it was properly latching.
Jul 3, 2018 4 demerits · 2 violations
Inspector comments: No night swimming. Pool closes by dark daily. Local permit number 18-600395.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Pump room has vent on door but fan for forced ventilation does not work.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. No air gap at backwash discharge.
Jun 13, 2017 8 demerits · 2 violations
#3 · Water quality: pool water pH −6
Maintain pool pH between 7.2 and 7.8. Observed pool pH at 6.8. The pH was corrected to 7.2 during inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Provide forced or cross ventilation in the chemical storage room. Observed no ventilation in chemical storage room.
Jul 12, 2016 10 demerits · 2 violations
#3 · Water quality: pool water pH −6
Observed PH at 7.0 at time of inspection. PH raised to 7.3
#18 · Premises: lifeguards present or warning signs posted −4
Observed warning signs without exact wording, Signs corrected to required wording requirements by writing in with a sharpie.
Sign on site states "Children should not use pool without adult supervision". Corrected to "Children should not use the swimming pool without adult supervision"
Sign on site states "Adults must not swim alone". Corrected to "Adults should not swin alone".
Jun 25, 2015 26 demerits · 7 violations
Inspector comments: 15. No recorded rope length known for ring buoy. Rope measured 28ft.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Maintain daily records of chlorine, pH and main drains. Maintain weekly records of total alkalinity and cyanuric acid. Observed no records being maintained.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed several tiles missing along top of pool wall.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed cross hair fitting in place on one return line. Provide correct fitting
#22 · Premises: emergency telephone provided −6
Provide emergency phone for use. Observed Kings III system present and not functioning. Unable to connect to Kings III operator or 911. IS issued.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed leaking pipes in pump room. Observed flow meter not functioning.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed no air gap for backwash line. Sightglass present.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Provide soap in restroom.
Jun 3, 2014 24 demerits · 6 violations
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Equalizer lines plugged. Corrected during inspection.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Pool wall is missing several tiles. Keep in good repair.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
One ladder is loose.
#22 · Premises: emergency telephone provided −6
Emergency phone is not working. Immediate Suspension issused.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter is not operating properly. Repair or replace.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
No backflow preventer on hose bib.