12demerits
WYNFIELD
14301 WYNFIELD CREEK PKY, Huntersville, NC 28078
Seasonal Swimming Pool · NC permit/State ID 2060500624
Latest result12 demerits
Last inspectedMay 21, 2026
Inspections on record13
On record sinceMay 2, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
May 2, 2014Lower is betterMay 21, 2026
Inspections & violations
May 21, 2026 12 demerits · 2 violations
Inspector comments: No permit restrictions
No night swimming
Inspection completed with CPO Lora Anderson.
Note: Pool not approved with salt as primary chlorination.
Note: Repair/Remodel of pool house has been completed and approved. Construction final has been conducted. Verified that handicap shower in women’s restroom has been sealed with aggregate that is slip resistant.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed throw rope > 50ft. CDI: corrected to 50ft during inspection.
#22 · Premises: emergency telephone provided −6
.2530(f) Provide signage with location of emergency phone if not visible from all areas inside pool enclosure. Observed no sign providing location of emergency phone. CDI: instructions and location written in on pool rules sign by CPO.
May 9, 2025 6 demerits · 3 violations
Inspector comments: PERMIT ISSUED. NO NIGHT SWIMMING AT THIS TIME. CPO stated that they will schedule a night inspection when they are ready for night swimming. Night swimming permit must have a night inspection and health department approval prior to night swimming.
Permit restrictions:
Pool to be closed to the public when construction on pump house begins and must remain closed until inspected and approved by the Health Department.
Note: POOL NOT APPROVED WITH SALT AS PRIMARY CHLORINATION.
#10 · Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints −2
.2523(e) Provide a minimum of 3/4 inch diameter safety rope at the breakpoint. Observed no safety rope at 5 ft breakpoint area of pool. CDI: CPO attached and secured a safety rope at the 5ft breakpoint.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed a leak occurring on flow meter creating water on floor. CDI: CPO adjusted the flow meter and sealed off the leak.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(m) Keep restrooms and fixtures clean and in good repair. Observed all showers in men’s restroom out of order and in poor repair. CPO stated that there are plans to remodel the bathroom after this pool season. Women’s showers will be Unisex during this season.
May 10, 2024 26 demerits · 6 violations
Inspector comments: Pool is permitted for night swimming and EHS will follow-up within one week to verify all lights are operational underwater and on pool decking. Pool has 6 aquastar WAV12WR101 2008 covers with light blue dot present. PDSC stated that the covers are 6 aquastar WAV12WR101 2017. Due to no suction hazard or flow issue, permit is being issued. However, a new PDSC form will need to be submitted within two weeks to reflect field verification today or permit will be suspended.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pool pH measuring at 8.2. CDI: CPO lowered pH to 7.8.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmer baskets full of debris. CDI: CPO cleaned and emptied skimmer baskets.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide at least 12 ft. long pole with body hook securely attached. Observed body hook with no screws to securely attach to 12 ft pole. CDI: CPO secured body hook with two screws.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
.2524(d) Provide sufficient underwater lighting. Observed 3 out of 5 underwater lights not operating properly. EHS will be following up with CPOs to ensure lights are functioning properly. CPO stated that they will send video of all lights functioning properly.
.2524(a) Pools that are to be used at night shall have sufficient artificial lighting provided. Observed two lights not functioning on pool deck. Pool has 11 other functioning lights. Lighting is sufficient for night swimming, however EHS will be following up with CPOs to ensure lights are replaced. CPO stated that they will send video of all lights functioning properly.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter stuck. CDI: CPO adjusted flow meter and it is now operational.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
.2518(d) Piping and valves shall be labeled with color codes or labels. Observed piping and valves not labels with direction of flow. CDI: CPO labeled piping and valves.
May 12, 2023 14 demerits · 3 violations
Inspector comments: (Verified 11 skimmers during inspection)
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed pool accumulating debris in need of cleaning.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmers full of debris in need of general cleaning.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Wrong number posted (CDI) corrected onsite.
Apr 27, 2022 10 demerits · 4 violations
Inspector comments: A noight lighting inspection was conducted in 2021.
Observed pool and deck lighting to be operational during today's inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed two weirs missing and one broken. Replace.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
One ladder missing bumper end caps. Replace
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Pump room has trash and some soda ash on floor that was spilt. Clean pump room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Mirrors are not shatterproof.
May 13, 2021 12 demerits · 3 violations
Inspector comments: Night swimming was verified in the field during inspection. Inside pool and deck lights were working properly. Facility also has stadium type lights. Night swimming was also verified in 2019. Night swimming is permitted.
Deck renovation was verified in field during inspection also. All surfaces on deck were smooth and sloped to the drain. Pictures were taken and emailed to Katie Rudisill.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed debris inside pool especially at stairs. Pool operator in process of vacuuming pool.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope length > 50ft. Rope cut to 50ft during inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(6) Provide sufficient lighting in chemical storage room. Observed no lighting in chemical storage room due to the lights not working. Repair
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed standing water in some areas of pump room.
Apr 15, 2020 4 demerits · 1 violation
Inspector comments: Equalizers have been plugged on wall properly but have not been plugged properly at the basket. Drain the water out of the lines and plug properly.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Some skimmers had a lot of debris. Keep them clean and functioning properly. Corrected during inspection.
Apr 22, 2019 20 demerits · 4 violations
Inspector comments: Pool is lifeguarded at all times per Swim Club Management. Night swimming is not permitted at this time.
#22 · Premises: emergency telephone provided −6
Emergency phone sign not posted. Corrected during inspection.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
PDSC form had equalizers as being plugged. Equalizers are not plugged and have Aquastar 6HPxxx covers (11 of them). Resubmit corrected PDSC form for approval. Corrected during inspection.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Pool floor needs vacuuming in deep end. Keep pool floor clean.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One weir is broken. Replace weir. Some baskets were full of debris. Clean baskets. CDI.
Apr 19, 2018 18 demerits · 4 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537 Pool walls and floor kept clean; Observed large amounts of debris collected on pool floor in need of cleaning.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518, .2537 Skimmers systems clean and in good repair; Observed all skimmers full of debris in need of cleaning.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530, .2537 Provide ring buoy with correct throw rope length; Observed throw rope measuring 60Ft. Rope cut to required length 50Ft.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528, .2537 Gates self-closing / self latching; Observed exit button stuck in open position not allowing gate to self-latch as intended. Button cover removed to prevent cover from pressing button in the open position.
May 12, 2017 20 demerits · 5 violations
Inspector comments: Permit posted at Meckpools.charmeck.org in 1-3 business days. Print a copy to post in the pool area.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
PDSC form does not match what is installed. 1 1/2" pipe for skimmer return lines, not 2" as indicated on form by flow for equalizer line covers. Corrected PDSC form submitted and approved.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
One of the throw ropes 52 feet. Corrected to 50 feet.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Some footholds on the outside of the fence. Maintain fence at least 48" high with no footholds.
#27 · Equipment room: filter backwash discharged through an air gap −2
Provide air gap for backwash.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water > 110F. Maintain at 110F or less.
Apr 15, 2016 0 demerits · 0 violations
No violations were recorded for this inspection.
Apr 17, 2015 0 demerits · 0 violations
Inspector comments: Observed gate repaired.Permit inspection passed. Facility permit not approved until available online.Mr. Andy Bennett present.
No violations were recorded for this inspection.
May 2, 2014 6 demerits · 2 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed handrails on ladders to be loose. CDI
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed stuck flow meters. CDI
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “WYNFIELD” or State ID 2060500624). Inspection type (routine vs. follow-up) is not published in the county's data.