‹ Back to search

8demerits

YMCA HARRIS KIDDIE POOL

5900 QUAIL HOLLOW RD, Charlotte, NC 28210
Seasonal Swimming Pool · NC permit/State ID 2060500631
Latest result8 demerits
Last inspectedMay 18, 2026
Inspections on record13
On record sinceMay 16, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01224 May 16, 2014: 0May 28, 2015: 6May 4, 2016: 24Apr 28, 2017: 14Apr 18, 2018: 4Apr 17, 2019: 14Apr 24, 2020: 0Apr 20, 2021: 10Apr 28, 2022: 6May 10, 2023: 16Jul 10, 2024: 0Apr 30, 2025: 12May 18, 2026: 8
May 16, 2014Lower is betterMay 18, 2026

Inspections & violations

May 18, 2026 8 demerits · 2 violations
Inspector comments: Permit Restriction - Flow meter must remain operable. Flow shall be kept at 43 gpm to 104 gpm or less to meet turnover and flow restriction of return pipe. Night swimming not approved.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. One ladder rail for railings closest to gate was observed to be loose. Operator tightened railing during inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide at least 12 ft. long pole with body hook securely attached. No body hook observed at pool. Operator placed a body hook with 12ft. Long pole at pool during inspection.

View this inspection on the county portal ›

Apr 30, 2025 12 demerits · 3 violations
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 7.0. CDI increased to 7.2 pH
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris in skimmer baskets.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. Observed pump room with less than 3 ft walking distance.

View this inspection on the county portal ›

Jul 10, 2024 0 demerits · 0 violations
Inspector comments: Inspection completed with David Williamson present. See notes below for plan review information. A. Permit Restriction - Flow meter must remain operable. Flow shall be kept at 43 gpm to 104 gpm or less to meet turnover and flow restriction of return pipe. FLOW AT 85GPM B. Pentair Intelliflo3 VSF 011077, 3 hp pump. VERIFIED AND ACCURATE. C. FlowVis flow meter reading above permit restriction. FLOW AT 85GPM. D. Main drain, skimmer and return line all 2” pipe. VERIFIED AND ACCURATE. E. (2) Aquastar 2008 24xxx drain covers. VERIFIED AND ACCURATE. F. (2) Pentair TR100 filters. COULD NOT VERIFY FILTER INFORMATION (DATA PLATE INFO WORN OFF). G. 6 returns. OBSERVED 6 RETURNS H. (4) skimmers with EQ lines plugged per State recommendations. OBSERVED 4 SKIMMERS WITH PLUGGED EQ LINES.

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 10, 2023 16 demerits · 4 violations
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 6.8 upon arrival. CDI- CPO corrected during inspection. Observed 7.3 prior to end of inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Observed door to entrance of women’s restroom at front gate not self-latching. CDI- maintenance person repaired during inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Observed broken grate for deck drain along fence. Not a trip hazard due to location along fence.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed small leak at flow meter resulting in some standing water on floor in pump room.

View this inspection on the county portal ›

Apr 28, 2022 6 demerits · 2 violations
Inspector comments: CPO David was present during the inspection. No night swimming approved. EHS has informed CPO to replace grout around pool deck and waters edge prior to permit inspection for next season. Permit will not be issued if correction not made.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Observed leaf debris and plastic in skimmers. CDI- CPO removed debris.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. - EHS unable to verify mirrors in restrooms are shatterproof. Provide documentation.

View this inspection on the county portal ›

Apr 20, 2021 10 demerits · 3 violations
Inspector comments: No night swimming. Observed some missing grout/caulk near back left skimmer of pool potentially leaving ability for tile to come loose. Ensure grout/caulk is in good repair and tile remains affixed.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed one missing weir. CDI: Weir was provided and installed during inspection.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool. Observed depth markers to be faded. CDI: Depth markers repainted during inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Observed some sodium bicarbonate stored in bags on floor of pump room.

View this inspection on the county portal ›

Apr 24, 2020 0 demerits · 0 violations
Inspector comments: 9. .2523 Depth markers on pool deck and pool wall shall be legible. Observed several painted depth markers on pool deck that are faded but still legible. These depth markers will need to be repainted/corrected prior to 2021 pool operating season. .2523 No diving markers on pool deck shall be legible. Observed faded no diving markers but still legible. These must be repainted/corrected prior to 2021 pool operating season. 29. .2526 Maintain restroom fixtures in good repair. Observed two hand sinks in men's and 2 hand sinks in women's locker rooms with water turned off due to leaks or handles of faucet broken.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 17, 2019 14 demerits · 3 violations
Inspector comments: PDSC information verified during inspection.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 6.8. Corrected to 7.2 during inspection.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed no area on water quality check list for recording cyanuric acid weekly. CDI- water quality check list was updated with cyanuric acid on sheet.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. Observed signage with wording "children should not use pool without adult supervision" posted (missing phrase 'the swimming'). CDI- new signage was placed that meets rule requirements.

View this inspection on the county portal ›

Apr 18, 2018 4 demerits · 2 violations
Inspector comments: JPerry verified PDSC form. The model# label has worn off of unit but it matches the picture of the model listed. Sent CSells and email from a Pentair representative stating he believes this is the correct model: Sta Rite Max E-Glas PE6H, 3HP.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladders shall be in good repair. One ladder rung is cracked.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
.2518(d) Piping and valves shall be labeled with color codes or labels. Labels were faded. Re-marked during inspection.

View this inspection on the county portal ›

Apr 28, 2017 14 demerits · 4 violations
Inspector comments: #6 PDSC form indicates that circulation pump is a Pentair Challenger CHII-NI-3, 3HP. Pump appears to be very old and information could not be obtained from pump. EHS unable to match pump to one in pump guide; however, motor is a 3HP. EHS to discuss w/ K. Wilson. Pool permit cannot be issued until issue resolved. Note: Water heater/ boiler not on at time of inspection. If hot water is provided to lavatories and showers, the maximum temperature allowed is 110F.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some algae on inset pool ladder steps. Some soil on pool wall tiles. ** Clean.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Painted deck depth markers and NO DIVING markers faded. ** Re-paint.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed some areas were deck chipped/ concrete missing creating >1/2" offsets. ** Corrected during inspections. Observed some cracks in deck. ** Maintain deck in good repair.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Restrooms not ready yet for season. Toilet partitions missing in both restrooms, no toilet paper provided yet, and all fixtures need cleaning. ** Complete.

View this inspection on the county portal ›

May 4, 2016 24 demerits · 5 violations
#3 · Water quality: pool water pH −6
Observed pH measuring 7.1 with chlorine at 8.0. Corrected during inspeciton and readings then were pH 7.2 and chlorine 5.0.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Daily written records were missing cyanuric acid and main drain checks. These items were being logged electronically. Corrected during inspection by adding printed sheets to three ring record binder.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed one equalizer cover attached to wall with 1/2" gap showing. Cover protrudes from wall less than 2".
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed gate not self latching. Springs were tightened during inspection and gate then securely latched.
#22 · Premises: emergency telephone provided −6
Observed signage at emergency phone listed number different than the one the operator had. Both numbers were correct. The sign was changed to match the number on record with 911.

View this inspection on the county portal ›

May 28, 2015 6 demerits · 1 violation
#22 · Premises: emergency telephone provided −6
Observed emergency phone not visible from pool deck and without signage indicated its location. CDI sign posted for location of emergency phone.

View this inspection on the county portal ›

May 16, 2014 0 demerits · 0 violations
Inspector comments: Permit issuedPermit available on website w/in 3 business days

No violations were recorded for this inspection.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “YMCA HARRIS KIDDIE POOL” or State ID 2060500631). Inspection type (routine vs. follow-up) is not published in the county's data.