34demerits
LEACROFT SWIM CLUB
4400 HIGHCROFT LN, Charlotte, NC 28269
Seasonal Swimming Pool · NC permit/State ID 2060500702
Latest result34 demerits
Last inspectedApr 9, 2026
Inspections on record14
On record sinceMay 9, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
May 9, 2014Lower is betterApr 9, 2026
Inspections & violations
Apr 9, 2026 34 demerits · 9 violations
Inspector comments: - Flow was close - 4 gpm below. Facility cleaning out debris. - Flow to remain between 354-391gpm.
- Signage for Emergency phones were hand written. Provide a permanent sign(s) so that it can be seen from all areas of pool enclosure.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed slight debris present. Clean as needed.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed slight debris present in skimmer baskets.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope length too long. CDI - Cut to 50ft.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Observed 4” vertical gap, 8” horizontal gap underneath fence by tennis courts. Repair
.2537(b) All gates and doors shall be self-closing, self-latching. Observed service gate not self-closing self latching. Gate seems to be blocked by shrubbery. But back shrubbery to allow for self-closing self latching gate. PIC stated gate is a service gate that remains locked all season.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed 1” gap in coping. CDI - Repaired with concrete. EHS recommends second layer.
#22 · Premises: emergency telephone provided −6
.2530(f) Provide signage with location of emergency phone if not visible from all areas inside pool enclosure. Observed emergency phone not visible from all areas and no signage pointing to location of phone. CDI - Sign was created and posted. Post more permanent sign.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Observed no cross ventilation in chemical storage room.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
.2518(d) Piping and valves shall be labeled with color codes or labels. Observed piping in need of re-labeling.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed backwash through air-break only.
May 23, 2025 20 demerits · 7 violations
Inspector comments: PDSC verified
Trim bush at service gate to allow self closing.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris.CLEAN
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Plugs missing from majority of skimmers. Several corrected during inspection. Return visit to verify.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2517(e) Secure starting platforms from use by removal; covering; or signage and active supervision.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. One inlet missing at step- corrected
#26 · Equipment room: valves and pipes identified by color codes or labels −2
.2518(d) Piping and valves shall be labeled with color codes or labels. LABEL PROPERLY
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
.2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. No backflow preventions in restrooms.
May 16, 2024 28 demerits · 6 violations
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pool pH measuring 6.8. CPO unable to correct during inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521(b) Ladders shall have slip-resistant tread. Observed top step of ladder without slip-resistant tread.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed one eyeball fitting not in place on return line. CDI: CPO replaced and secured eyeball fitting.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed two buoy ropes measuring over 50ft. CDI: CPO cut ropes to 50ft.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed entry gate unable to self-close self-latch. CPO unable to correct during inspection.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Observed emergency phone unable to receive incoming calls. CPO unable to correct during inspection.
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed telephone number faded and no longer clearly visible. CDI: CPO touched up phone number with marker and it is now visible.
May 16, 2024 2 demerits · 1 violation
Inspector comments: Pool is not permitted for night swimming.
Permit issued.
Front door entry is self-closing, self-latching with electronic key fob entry. After discussion with Supervisor, H. McIntosh, it is determined that this door is in compliance for a pool entry barrier. Secondary gate leading to pool (after door) is to be repaired and EHS will follow-up.
EHS verified VFD must remain set so that pressure gauges read 14 psi and 7 Hg. Flow meter could not be installed per mfg. specifications but is operable. Flow shall not exceed 500 gpm on pump curve based off pressure gauge readings.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521(b) Ladders shall have slip-resistant tread. Observed top step of ladder without slip-resistant tread. Replace.
Apr 14, 2023 10 demerits · 3 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed debris on pool floor.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter note operational at time of inspection . CDI PIC replaced with new flow meter.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. Mirrors in restroom not shatterproof.
May 19, 2022 14 demerits · 3 violations
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8.observed ph 7.1. Raised to 7.4
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed debris in pool
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational.observed flow meter stuck. Corrected onsite
May 21, 2021 4 demerits · 1 violation
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. - Observed pool debris during the inspection.
May 6, 2020 8 demerits · 2 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. - Observed debris on pool floor.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Observed debris in skimmers.
May 9, 2019 22 demerits · 4 violations
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. pH 7.0 on arrival. Brought up to 7.4 while on site.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Rope measured 60 ft. Cut to 50 ft while on site.
.2530(a) Pole for body hook must be non-telescoping, non-adjustable, and non-collapsible. Pole attached to body hook consisted of two 12' poles taped together. Poles untaped to produce one stable 12' pole.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Sign at pool phone indicated right numerical address but street name was incorrect. Corrected to correct street name while on site.
Apr 5, 2018 16 demerits · 4 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
Observed skimmer baskets that were full of debris and equalizer covered with debris.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
Observed deck with cracks greater than .5" and uneven surface where it can cause a trip hazard.
#22 · Premises: emergency telephone provided −6
.2530(a) Emergency phone shall remain operable.
Emergency is operable and able to reach 911 and have correct number and address but heavy static on the line makes it difficult to hear person on the other line.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
.2518(d) Piping and valves shall be labeled with color codes or labels.
Observed no labels showing flow of water at pipes near pump.
May 18, 2017 0 demerits · 0 violations
Inspector comments: CPO advised that pool will be replastered in the winter season. Ensure that the stairs are part of this process as they are showing some wear and fading on the stripes. Pool has passed pre-inspection. Post permit in public view from the deck.
No violations were recorded for this inspection.
Jul 14, 2016 42 demerits · 10 violations
Inspector comments: Pool rules not readily visible by pool bathers. Recommend placing signage such that bathers can easily see pool rules.
Pool and wading pool tied together by fill line. Fill line connected to suction side of pool pump (at vacuum line). Will make another visit to assess what corrective action will need to be made.
Intent to suspend issued.
5)
8)
17)
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No TA or CYA checks on site. Check daily Cl, pH, main drains and at least weekly TA and CYA. These records need to be readily available when an inspection is conducted. - Intent to suspend item.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
PDSC form does not match what was observed. Observed 11 skimmers, with (8) 4HPxxx and (3) 6HPxxx covers. - Updated PDSC form submitted and approved.
One EQ cover cross threaded, one side with large gap between cover and the wall. Corrected by operator.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Missing half of the weirs. Provide functional weirs for skimmers. - Intent to suspend item.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
One ladder missing non-slip treads. Maintain ladders and handrails secure and in good condition.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Missing a few inlet fittings. Install functional inlet fittings.
#13 · Pool maintenance: contrasting band on steps and benches −4
Contrasting color band on steps faded. Recommend repainting at the end of the season.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Pool with one lifeguard on duty. Provided ring buoy with 58 foot throw rope. Corrected to 50 feet.
Pool with one body hook. Provide two body hooks on at least 12 feet non-collapsible pole. Corrected by operator.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Deck damaged in a few places. Patch deck.
Deck chairs too close to pool edge. Maintain at least 8 feet clearance around pool. - Intent to suspend item.
#22 · Premises: emergency telephone provided −6
Provide signage at emergency phone with address and phone number. Corrected by operator.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hole in wall in men's restroom. Maintain restrooms in good condition.
May 8, 2015 4 demerits · 1 violation
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed the pool floor with leaves and debris. **Keep the pool floor clean at all times.General Comment - Adam Kennell was present during the inspection.Observed the backwash sewer drain was very slow to drain. **Have sewer drain repaired so that water does not remain i the sewer pipe.***The pool permit will be available for printing in 3 days at meckpools.charmeck.org
May 9, 2014 6 demerits · 2 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Clean the pool wall tiles and debris on the pool floor.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Replace the missing end cap on the ladder.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “LEACROFT SWIM CLUB” or State ID 2060500702). Inspection type (routine vs. follow-up) is not published in the county's data.