0demerits
GLENHAVEN APARTMENTS
3117 TACOMA ST, Charlotte, NC 28208
Seasonal Swimming Pool · NC permit/State ID 2060500715
Latest result0 demerits
Last inspectedJun 23, 2026
Inspections on record13
On record sinceJul 2, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jul 2, 2014Lower is betterJun 23, 2026
Inspections & violations
Jun 23, 2026 0 demerits · 0 violations
Inspector comments: Permit Issued
No violations observed
No night swimming
Permit Restriction Followed: Flow meter must remain operable. Flow shall not exceed 70 gpm due to pipe and filter restrictions. Turnover is not met due to restrictions in pump room. Flow greater than 119 gpm exceeds drain covers. Suction Hazard.
No violations were recorded for this inspection.
Jun 3, 2026 10 demerits · 2 violations
Inspector comments: Permit denied due to:
.2530(f) Failure to provide a working emergency phone.
.2537(b) All gates and doors shall be self-closing, self-latching
Pool requires reinspection prior to opening. Call Environmental Health front office when ready to request a reinspection. $100 fee
required. 980-314-1620
Pool Permit Condition verified
Permit Restriction: Flow meter must remain operable. Flow shall not exceed 70 gpm due to pipe and filter restrictions. Turnover is not met due to restrictions in pump room. Flow greater than 119 gpm exceeds drain covers. Suction Hazard.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed gate to pool not self latching/closing with automatic electromagnetic lock system not functioning properly.
#22 · Premises: emergency telephone provided −6
.2530(f) Pool telephone shall be capable of directly dialing 911 or another emergency notification system. Observed kings 3 emergency box not connecting to kings 3 or 911 after several attempts by EHS and CPO. CPO used personal phone to call listed number 704-394-7087 fax-style noise was audible only. CPO called customer service and was told a technician would need to be onsite to fix issue.
Jun 2, 2025 16 demerits · 3 violations
Inspector comments: PERMIT RESTRICTIONS:
1. PUMP MUST REMAIN SET AT SPEED 2350 RPM.
2. FLOW METER MUST REMAIN FUNCTIONABLE NOT TO EXCEED 70 GPM DUE TO PIPE AND FILTER RESTRICTIONS.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Observed initial chlorine reading at 0.5 ppm. CDI - Pool chlorine was adjusted during inspection to a level of 1.25
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide at least 12 ft. long pole with body hook securely attached. Observed body hook attached with plastic push tabs. CDI - CPO replaced body hook with hook attached by bolted metal screw.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. Observed rules sign with incorrect wording (I.e. "Children should not use the pool without adult supervision." CDI - Handwritten pool sign with 1.5” lettering was hand drawn and posted by CPO.
May 20, 2024 10 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope measured 40’
Cpo corrected during. Inspecton
May 23, 2022 0 demerits · 0 violations
Inspector comments: Pool operating hours are from 10am - 6pm. No night swimming visit is required. Night swimming is prohibited.
No violations were recorded for this inspection.
Jul 9, 2021 8 demerits · 2 violations
Inspector comments: No night swimming permitted.
50 GPM (per instructions not to exceed 70 GPM)
Infield checklist of plan review performed by Inspector before permitting.
Issuance of permit by this Department does not negate meeting requirements of Executive Order 195 or subsequent Orders in effect unless such Orders are rescinded or superseded by another appilcable Order.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed leaves and other tree debris on pool floor. CDI-PIC cleaned pool floor.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed an inch difference from skimmer lid to the pool deck. Instructed CPO to make needed permenant repairs during the offseason. CPO will make temperary repair during season
May 15, 2020 4 demerits · 1 violation
Inspector comments: 80 GPM
No night swimming permitted
**Facility understands that although the pool is permitted, it will not open until Mecklenburg County and the State of NC declares it to be safe to do so.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Increase the water level of pool to insure the skimmers are operating properly. Corrected by pool operator.
May 9, 2019 2 demerits · 1 violation
Inspector comments: 17. Observed some cracks along to pool deck that will need attention in the future. Pool is NOT permitted for night swimming. Swimming time will be from Dawn til Dusk.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. Observed bags of chemicals stored at floor level. Place chemicals on shelf.
May 25, 2018 24 demerits · 6 violations
Inspector comments: Most issues from previous inspection corrected.
Records are not yet being kept. Ensure that Cl, pH, main drains, and pool maintenance activities are checked and recorded daily. Record at least weekly total alkalinity and cyanuric acid.
Anchor for handrail broken. Maintain handrail secure and properly installed.
Pump motor not bonded to the pool. Did not observe a bonding wire.
Ensure that outlet for newly installed liquid chlorine and acid system is properly installed. Ensure all required Code Enforcement permits are obtained.
Permit #18-600049 issued.
Permit issued with the following conditions:
No Night Swimming
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Water level above the skimmers. Maintain proper water level so that skimmers function properly. Corrected by operator.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Floor return cracked. Replaced by operator.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
New body hook and 12 foot pole missing screws. Removed by operator. Will use old pole until can get screws for it.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Back gate not-self closing. All gates shall be self-closing and self-latching. Corrected by operator.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Table too close to pool. Maintain at least 5 feet clear walkway around the pool. Corrected by operator.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Fan for chemical storage part of pump room tied to light switch. Fan for pump room part of pump room not functioning. Provide either cross or forced air ventilation. Fan shall run continuously and not be tied to the light switch.
Jun 8, 2017 20 demerits · 5 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Replace missing weir in skimmer.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy missing throw rope at time of inspection. Throw rope attached to ring buoy at time of inspection. Corrected at time of inspection
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Keep a six feet clearance around pool deck. Observed chairs too close to swimming pool.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter stuck. Repair flow meter.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed ventialtion tie in with light switch in pump/chemical room. VEntilation in pump room shall be continous and not tie to the light switch or provide cross ventilation in pump/chemcial room.
POST POOL PERMIT NEAR OR WITHIN SWIMMING POOL AREA. Sign provided inside of pool area stating "telephone is located on side of office building"
Jun 20, 2016 18 demerits · 4 violations
#3 · Water quality: pool water pH −6
pH at 6.8
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Main rains listed at Hayward WG1048E. SDX Retros actually installed.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder very loose and needs to be tightened.
#18 · Premises: lifeguards present or warning signs posted −4
No "Adults should not swim alone" sign posted.
Jun 24, 2015 42 demerits · 10 violations
Inspector comments: Glue on ring buoy coming loose. Recommend replacing ring buoy.Permit not posted. Print permit at meckpools.charmeck.org and post in pool area.Immediate suspension issued.3)6)Contact Will Harrison 704-336-5528 for reinspection when issues have been corrected.
#3 · Water quality: pool water pH −6
pH < 6.8. Maintain between 7.2 and 7.8. - Immediate item
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed two records from the end of May, no other records observed. Check daily Cl, pH, main drains and at least weekly cyanuric acid and total alkalinity. Pools usually closed on Mondays, this should be reflected in the pool log. - Intent item.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
One equalizer line cover missing. Install A112 approved equalizer line cover. - Immediate item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmer missing weir. Install functional weir.
#13 · Pool maintenance: contrasting band on steps and benches −4
Contrasting color band currently tiled diagonally with wide gaps between tiles. Provide at least a two inch wide contrasting color band within one inch of step edge if using tile, or at the edge if painted. - Intent item.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope tied to fence. Rope cannot be tied to fence. Corrected by operator.Throw rope too long. Corrected to 30 feet by operator.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
Observed chlorine tablets in all three skimmer baskets. Use only NSF approved chlorinator for chlorinating the pool. Corrected.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. Repair or replace.Provide spare pump basket. None observed.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Fan in pump room tied to the light switch. Fan shall run continuously.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Not all pipes labeled. Label pipes.
Jul 2, 2014 28 demerits · 7 violations
Inspector comments: #17 Chairs @ end of pool closest to office are ~5' from pool edge. ** Maintain 6' of clear walking space.
GC #22 Directions to location of emergency phone is secured to the outside of pool fence near resident gate. ** Provide clear directions to emergency phone inside the pool enclosure.
GC #25 Forced air vents in equipment / chemical room operate on light switches. ** Fans should run continuously.
IMMEDIATE SUSPENSION issued for #6 & #15.
Note: Strong chlorine odor on skin when contact with pool water. Verify if combined chlorine problem or some other chemistry problem & resolve.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Pool record does not include a column for main drain checks. ** Check main drains daily & indicate on pool record form. Gave MCHD sample monthly pool record form.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
One equalizer line cover missing. ** Install (same make/ model as others). Immediate suspension
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Missing 1 of 3 weirs. ** Install.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Rope around ring buoy dry rotted & throw rope dry rotted. ** Replace buoy. New rope on-site. Ring buoy must be US Coast Guard Approved. Immediate suspension.
#18 · Premises: lifeguards present or warning signs posted −4
Lack sign "CHILDREN SHOULD NOT USE THE SWIMMING POOL WITHOUT ADULT SUPERVISION'. Letters must be at least 1" in height.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water @ lavatory in restroom 125.4F. ** Maximum allowed is 110F.
Restroom lavatory, toilet & floor need to be cleaned. ** Clean all.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Observed hose down in pool water & is the means that water is added to the pool - hose bib does not have any backflow prevention. ** Install vacuum breaker on hose bib.