MAA SOUTH PARK
4835 CAMERON VALLEY PKWY, Charlotte, NC 28210
Seasonal Swimming Pool · NC permit/State ID 2060500729
Latest result0 demerits
Last inspectedMay 21, 2026
Inspections on record16
On record sinceApr 21, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Apr 21, 2014Lower is betterMay 21, 2026
Inspections & violations
May 21, 2026 0 demerits · 0 violations
Inspector comments: NEW PERMIT RESTRICTION: All flow meters must remain operable. Flow Required on pump 3 (011076) at 93 GPM to 103 gpm so
not to exceed return line from system (2”). Main flow meter at return line at slab shall be required at least 225 gpm to meet turnover.
93 gpm required to maintain minimum turnover combined with other 2 systems.
EHS verified flow meters during inspection: EHS observed main flow meter on return line into slab above 225gpm and flow meter for pump 3 at 100gpm
No violations noted during inspection
No violations were recorded for this inspection.
May 20, 2026 8 demerits · 2 violations
Inspector comments: EHS verified the following items onsite during inspection.
1. Pump 3 is a Pentair Intelliflo 3VSF 011076 3 Hp
2. For 2 pump system: 1 4inch main drain line, 2 3 inch skimmer lines, and 1 4 inch return line into the slab.
3. There is a total of 6 main drains in the pool. 4 Aquastar A10RCFRxxx 2017 drain covers.
4. Verified there is a Pentair sand filter onsite for pump 3. There is no data plate for sand filter.
5. 9 total skimmers
6. 26 total returns.
NEW PERMIT RESTRICTION: All flow meters must remain operable. Flow Required on pump 3 (011076) at 93 GPM to 103 gpm so not to exceed return line from system (2”). Main flow meter at return line at slab shall be required at least 225 gpm to meet turnover. 93 gpm required to maintain minimum turnover combined with other 2 systems.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed minor debris in skimmer baskets.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter on return line reading 210 GPM, and flow meter for pump 3 reading 70 GPM during inspection. Pool tech was unable to turn up variable speed pump during inspection.
Pool has the following permit restriction: All flow meters must remain operable. Flow required on pump 3 (011076) at 93gpm to 103gpm so not exceed return line from system (2”). Main flow meter at return line at slab shall be required at least 225 GPM to meet turnover. 93gpm required to maintain minimum turnover combined with other 2 systems. Permit Denied.
Apr 30, 2026 30 demerits · 6 violations
Inspector comments: Re-inspection fee is required. Call Main office at 980-314-1620 once all 4 and 6 point demerits are corrected.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Observed facility with a new pentair intellifllow pump installed. Pump does not match what is listed on the PDSC form. Submit new PDSC form for approval. Permit denied.
.2539(b) All suction fittings shall be installed in accordance with the manufacturer's instructions. Observed pool having two vacuum lines according to CPO. One vacuum line is missing a cover, the other vacuum line has a self closing self latching cap which does not latch properly. Permit denied
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope exceeding 50ft. CPO cut rope to 50ft.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed the door leading to restrooms and gym not self-latching. Permit denied
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed deck chair within 6ft of waters edge. CPO relocated chair.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. Observed facility without a sign with this statement in exact lettering and size requirements. Permit denied
.2530(c) Provide "Adults should not swim alone." in 1" lettering. Observed facility without a sign with this statement in exact lettering and size requirement. Permit denied
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed dialing instructions on sign stating “dial 911” facility has a 3 kings box which consumer has to push a button to call 911. CPO corrected sign during inspection.
May 16, 2025 14 demerits · 3 violations
Inspector comments: Will check back that floor return and 1 ring buoy replaced. Will return 5/23/25 to check replacements, or pool will be closed until replacement.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed one missing weir. CDI-replaced
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed hairline crack in floor return. Replace.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(b) Two units of lifesaving equipment (or two lifeguards) must be provided for pools that exceed 3,000 sq. ft. surface area. Observed one ring buoy with some dry rotting. Replace.
May 16, 2024 4 demerits · 1 violation
Inspector comments: Previous items corrected.
Permit issued.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed areas of decking pavers sinking around skimmers and coping.
.2537(2) Decks shall be kept in good repair.
May 10, 2024 12 demerits · 3 violations
Inspector comments: Infield plan review complete.
Verified PDSC form data.
Pool permit not issued for:
Return fitting missing on floor.
Return fitting on wall possible to equalizer.
Gate upstair not self closing self latching.
Door to restrooms not self closing self latching.
Depth markers 4 1/2' on wall.
.2523(a) Provide depth markers on pool walls and pool deck next to the swimming pool.
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm.
.2537(b) All gates and doors shall be self-closing, self-latching.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Observed depth markers at wall near volleyball net with 4 1/2' inside and 4' on deck. Pool depth is 4'.
.2523(a) Provide depth markers on pool walls and pool deck next to the swimming pool.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed return fitting on wall equalizer line. Cap on wall and in skimmer.
Observed one missing return fitting on floor.
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed pool gate not self closing self latching.
Observed doors to pool deck from restrooms not self closing self latching.
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm.
.2537(b) All gates and doors shall be self-closing, self-latching.
Apr 13, 2023 12 demerits · 3 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs.
One of nine skimmer weirs observed missing. CPO had replacement weir and repaired during inspection. Corrected.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
Observed one floor return face plate missing. CPO has replacement plates.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed 2/3 flow meters stuck. Repair to operational status. CPO repairing on site.
May 16, 2022 8 demerits · 2 violations
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed 2 floor return without face plates . CPO has face plates on site to put on.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meters stuck. Repair to operational status.
Apr 14, 2021 2 demerits · 1 violation
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521(b) Provide at least one handrail on steps. Handrail on steps at 3 1/2 feet is loose and the bottom cap is loose as well.
May 22, 2020 4 demerits · 1 violation
Inspector comments: Inspection completed with Ryan Becker
“Issuance of a permit by this department does not negate closure required by Executive Order No. 120 or subsequent orders in effect unless such Orders are rescinded or superseded by another applicable Order”
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed holes that were greater than 1/2” on pool deck that was used for volleyball net uncovered. CDI PIC went to plug holes to prevent trip hazards.
.2537(2) Decks shall be kept in good repair. Observed white cement portion of deck that was cracking and in need of repair but not large enough to cause trip hazard.
May 1, 2019 4 demerits · 1 violation
Inspector comments: No night Swimming.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed several skimmers with buildup along the interior.
May 15, 2018 2 demerits · 1 violation
Inspector comments: Unable to verify if bathroom mirrors are shatterproof
Emailed to T. Brown and verified receipt before leaving.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed damage to the chemical and filter room walls
May 10, 2017 28 demerits · 6 violations
Inspector comments: Joe Brennan with Carolina pool management was present during the inspection.
#3 · Water quality: pool water pH −6
Observed pH at a 7.0. CDI- The CPO brought the ph to a 7.2.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed one loose hand rail.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed throw rope at 52FT. CDI- CPO cut rope down to 50FT.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed one gate not self closing. CDI- CPO had property management apply a spring to the gate so it would properly close.
#22 · Premises: emergency telephone provided −6
Observed emergency phone sign not visible from all points of the pool deck. CDI- CPO added the location of the emergency phone to one set of pool rules.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed one pressure gauge non-functional. CDI- CPO applied a functioning gauge.
Also observed two flow meters non-functional. CDI- CPO was able to get flow meters functioning.
The pool management company will work with the regulatory authority to get a long term fix on the flow meters.
Jun 14, 2016 12 demerits · 3 violations
Inspector comments: Intent to Suspend permit issued for item 5. You have 30 days to correct or permit will be suspended.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Main drains are not being checked daily. Check main drains daily. Cyanuric acid and Alkalinity are not being checked weekly. Check weekly
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
3 out of 10 weirs are missing. Replace.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
There are 3 pumps. Two of the three flow meters are not operating properly.
Jun 3, 2015 16 demerits · 3 violations
#3 · Water quality: pool water pH −6
Observed pH at 7.0 ppm. CDI- corrected tom 7.3 ppm.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Observed suction hazard, a missing equalizer adapter.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed fence not to be self closing. CDI- locked with padlock until repairs can be made.
Apr 21, 2014 12 demerits · 3 violations
Inspector comments: 8. One equalizer line plugged in skimmer. Unplugged.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
One ring buoy rope length at 54'. Cut to 50' during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
One gate was stuck when opened all the way. Corrected.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Restroom hot water is 117F. Should be 110F or less.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “MAA SOUTH PARK” or State ID 2060500729). Inspection type (routine vs. follow-up) is not published in the county's data.