4demerits
HENDERSON PARK
7644 HENDERSON PARK RD, Huntersville, NC 28078
Seasonal Swimming Pool · NC permit/State ID 2060500743
Latest result4 demerits
Last inspectedApr 30, 2026
Inspections on record13
On record sinceApr 23, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Apr 23, 2014Lower is betterApr 30, 2026
Inspections & violations
Apr 30, 2026 4 demerits · 1 violation
Inspector comments: PDSC form verified to be in compliance during today’s inspection. No existing permit restrictions/conditions.
Critical items observed were corrected during today’s inspection with CPO Patrick Wright.
Not permitted for night swimming. Permit sticker issued. Permit will be available on Mecklenburg County website within 24 hours.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed areas on pool deck with offsets > 1/2” resulting in dangerous trip hazards. CDI - CPO repaired areas.
Apr 25, 2025 0 demerits · 0 violations
Inspector comments: No night swimming
No violations noted during inspection
No violations were recorded for this inspection.
Apr 30, 2024 0 demerits · 0 violations
Inspector comments: No violations noted during inspection. Night swimming is not permitted.
No violations were recorded for this inspection.
Apr 24, 2023 0 demerits · 0 violations
Inspector comments: No violations noted during inspection
Night swimming NOT permitted
No violations were recorded for this inspection.
Apr 25, 2022 4 demerits · 1 violation
Inspector comments: Patrick Wright present during the inspection.
Verified Pumps and main drains.
Night swimming NOT permitted.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Twig in main drain. CDI - CPO removed during the inspection.
May 18, 2021 4 demerits · 1 violation
Inspector comments: Night swimming NOT permitted.
Facility installing chlorine automatic feeder- verify @ 2022 permitting inspection.
Inspection completed with Patrick Wright.
Report to 'Patrick Wright'
No signature due to COVID-19.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter on return line stuck. CDI: CPO corrected.
Apr 24, 2020 26 demerits · 7 violations
Inspector comments: Inspection conducted with Benji Sheehan. Due to COVID-19 precautions, inspection was not signed by the operator.
Emergency phone signage heavily faded. Recommend replacing with a new, more visible emergency phone sign.
Permit issued
No Night Swimming
Prior to next year's permit being issued, the following need to be corrected:
Contrasting color bands on steps.
Gap under main gate > 2". Ensure that magnetic latch does not create a foothold and that magnet operates on a battery backup or has another latch meeting requirements to serve as a backup in case of a loss of power.
“Issuance of a permit by this department does not negate closure required by Executive Order No. 120 or subsequent Orders in
effect unless such Orders are rescinded or superseded by another applicable Order.”
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Half of the skimmers not functioning. One of the skimmer valves turned off in the pump room. .2518(k) The flow-through rate through any one recessed automatic surface skimmer shall be between 20 gallons per minute and the maximum flow the skimmer is certified for under NSF Standard Number 50. Corrected by operator.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
One ladder loose. .2521 Install ladders per manufacturer instructions.
#13 · Pool maintenance: contrasting band on steps and benches −4
Contrasting color band as much as 1.5 inches from edge of the steps. .2521(b) Provide at least 2"x 2" tile for contrasting color band within 1" of adjacent tiles and edge of the stair tread. OR .2521(b) Provide at least 2" contrasting color band to edge of stair treads. This will need to be corrected before 2021 permit will be issued.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
New ring buoy and throw rope. .2530(a) Provide USCG approved ring buoy with 50 foot throw rope. Corrected by operator.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Pre-2010 gate with gap > 2" under the gate. .2528(a) Maintain 2" or less under the gate. This will need to be corrected before 2021 permit will be issued.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Vacuum cap missing. .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. Corrected by operator.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Pump room light not functioning. .2533(b) Provide sufficient lighting in pump room.
May 15, 2019 0 demerits · 0 violations
Inspector comments: No violations.
No violations were recorded for this inspection.
Apr 12, 2018 8 demerits · 2 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537 Pool floor kept clean; Observed large amounts of debris collected on pool floor in need of cleaning.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522. .2537 Decks free of obstructions; Observed pool chairs stored too close to pool edge (within 6ft).
Mar 31, 2017 8 demerits · 3 violations
Inspector comments: Far side of deck chipping. Recommend patching deck. Maintain free of trip hazards.
Emergency phone signage faded. Recommend replacing emergency phone signage.
Permit will be issued online at Meckpools.charmeck.org within 3 business days. Print copy of permit to post in the pool area.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One skimmer equalizer line plugged. Provide functional skimmers. Corrected by operator.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder not properly anchored into pool deck. One side sticking up ~ 2 inches. Corrected by operator.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water > 110F. Maintain at 110F or less.
Apr 13, 2016 2 demerits · 1 violation
Inspector comments: PDSC verifiedPre-permit inspection approved.Pool cannot open until permit is availale online and the date valid is met.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed hot water over 110 degrees F. Temper hot water between 90 and 110.
Apr 2, 2015 6 demerits · 2 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed leaves and debris in pool. Clean.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed one ladder to be loose. Repair.
Apr 23, 2014 18 demerits · 5 violations
Inspector comments: Permit will be posted online within 3 days. Post visible on pool deck.
#3 · Water quality: pool water pH −6
Observed pH at 7.0. Corrected to 7.4.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed one skimmer with build-up. Corrected during inspection.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed the line to chlorinator leaking. Repair.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed one stall without toilet paper in women's. Provide toilet paper.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Observed no backflow prevention device on hose bibs. Provide backflow prevention devices.