6demerits
HAMPTON INN & SUITES
401 TOWNE CENTRE BLVD., Pineville, NC 28134
Seasonal Swimming Pool · NC permit/State ID 2060500762
Latest result6 demerits
Last inspectedMay 22, 2026
Inspections on record11
On record sinceMay 9, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
May 9, 2014Lower is betterMay 22, 2026
Inspections & violations
May 22, 2026 6 demerits · 2 violations
Inspector comments: NIGHT SWIMMING NOT APPROVED
PERMIT RESTRICTION: FLOW METER MUST REMAIN OPERABLE. FLOW REQURIED AT 39 GPM TO 63 GPM TO MEET TURNOVER AND FLOW RESTRICTION OF THE FILTER. GREATER THAN 100 GPM IS A SUCTION HAZARD FOR DRAIN COVER.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris in skimmers.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap at backwash line.
Jul 18, 2025 4 demerits · 1 violation
Inspector comments: Pool inspection completed within
CPO Shiv Amin C-142630.
Flow meter not to exceed 60 GPM.
Observed all items in compliance with updated PDSC.
No night swimming.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris, leaves and bugs inside skimmers.
CDI - skimmers dumped/cleaned.
May 21, 2025 34 demerits · 7 violations
Inspector comments: Pool permit denied.
Pool inspection completed with Shiv Amin.
CPO expired may 14, 2025
Observed pump and motor not matching PDSC form on file.
Pump and motor must go through senior review and approval process.
Pool may need electrical permit.
Establishment is required to submit new PDSC form.
Contact Senior EHS Katie Rudisill to get PDSC process information.
New drain covers and filters replaced 3 weeks ago, same covers.
Katie.Rudisill@mecklenburgcountync.gov
704-309-5494
When process is complete please request re-inspection.
Jordan Johnson 704-280-0454
Hope McIntosh
Hope.McIntosh@mecklenburgcountync.gov
980-229-7549
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance.
PDSC form not accurate. Main Drain covers replaced, pump and motor replaced with no updated PDSC form.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
Observed floating debris in skimmers.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(a) Provide depth markers on pool walls and pool deck next to the swimming pool.
Observed depth markers missing from pool walls.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
Observed ring buoy rope longer than 1.5 times the width of the pool.
CDI - Rope reduced to 23 ft.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering.
.2530(c) Provide "Adults should not swim alone." in 1" lettering.
Premises did not have signage with the exact wording.
Signage must be ordered.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone.
Observed incorrect call back number at the emergency phone.
CDI - Phone number corrected.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(h) Provide approved pump in good repair.
Observed pump and motor changed, motor and pump do not match the PDSC form on file.
PDSC form shows pentair ch11-N1-3/4 FE observed pentair vsf011056 1.88 Hp
May 25, 2022 20 demerits · 6 violations
Inspector comments: Night swimming is not approved. CPO Rondell Pauling was present during the inspection. NOTE: Pool wall/floor shall be re-evaluated prior to permitting next year (2023) due to ladder damage and minor noted chips.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. - Observed pool floor with debris on them. EHS able to verify main drains. CDI- CPO started cleaning pool floor during inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. - Observed both ladders in 5Ft side with missing rubber caps.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. - Observed ring buoy rope to be 25ft. CDI- CPO provided rope at 23ft.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. .2530(c) Provide "Adults should not swim alone." in 1" lettering. - Observed pool rule sign without above statements. CDI- PIC provided correct pool rule sign with provided statements.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. - Observed pump room with standing water. EHS did not observe any leaking pipes.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. - CPO and EHS were unable to verify mirrors in restroom are shatterproof.
Jul 1, 2021 2 demerits · 1 violation
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Both ladders in the 5' section are missing bumpers. Replace bumpers.
May 16, 2019 12 demerits · 3 violations
Inspector comments: PDSC form reviewed. Night swimming is not permitted.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH levels at 7.0. CPO increased pH level to 7.8 by the end of the inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris build up in skimmers. CPO emptied skimmer baskets during the inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Observed missing end caps on ladder at 4 FT depth of pool. Ensure to replace.
May 16, 2018 4 demerits · 1 violation
Inspector comments: Local Permit # 18-600768
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Add main drain check daily to daily log. (Corrected during inspection)
May 16, 2017 8 demerits · 2 violations
Inspector comments: This is not a pool permit. Permit will be available on the website within 2 to 3 business days at meckpools.charmeck.org
#18 · Premises: lifeguards present or warning signs posted −4
Observed no lifeguard on duty sign posted not compliant and did not state "WARNING - NO LIFEGUARD ON DUTY" in 4 inch letters exact wording. CDI, operator posted additional warning lettering to sign while on-site. Observed other signage such as "Children should not use the swimming pool without adult supervision" and no "Adults should not swim alone" not with exact wording at least 1 inches high.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter stuck. Operator repaired flow meter while on-site.
May 20, 2016 6 demerits · 2 violations
Inspector comments: Intent to Suspend issued. Repair step color bands to w/in 1" of stair edge if tiled. -- If paint, all the way to the edge.
Contact Tim Dutcher 704-336-5553 when corrected.
#13 · Pool maintenance: contrasting band on steps and benches −4
Tiles on steps > 2" from stair edge.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
No backflow prevention on pool deck hose bibs
Apr 16, 2015 10 demerits · 4 violations
Inspector comments: #5 No cyanuric acid levels being recorded. ** Cyanuric acid column added to log sheet & CPO reports that he will conduct test & record 1 time per week.
GC #25 Equipment room does not have any forced air ventilation or cross ventilation. ** Install forced air ventilation. (Note: No door in place between equipment room & chemical room and at time of inspection strong forced air ventilation in chemcial room.)
Approved metal screening (to prevent gate latch access) has been installed as required on gate & fence.
POOL PERMIT CAN BE ISSUED.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
No protective plates covering bolts on handrail & 1 broken on ladder. ** Install/ Replace.
#13 · Pool maintenance: contrasting band on steps and benches −4
Tiles on steps ~2" from leading edge of the steps.
** Maximum allowed is 1".
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water >110F at lavatories in restroooms.
** Maximum allowed is 110F.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Hose bib with hose on pool deck does not have back flow prevention. ** Install vacuum breaker.
Over-the-rim spout 7" from ladder & extends 6" passed edge of pool. ** Over-the rim spout should be no > 6" from ladder & no > 2" passed pool edge.
May 9, 2014 0 demerits · 0 violations
No violations were recorded for this inspection.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “HAMPTON INN & SUITES” or State ID 2060500762). Inspection type (routine vs. follow-up) is not published in the county's data.