CAMDEN SEDGEBROOK

16930 SEDGEBROOK LANE, Huntersville, NC 28078
Seasonal Swimming Pool · NC permit/State ID 2060500775
Latest result6 demerits
Last inspectedApr 21, 2026
Inspections on record13
On record sinceMay 8, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0918 May 8, 2014: 18Apr 16, 2015: 8Apr 8, 2016: 4Apr 27, 2017: 2Apr 3, 2018: 6May 1, 2019: 6Apr 28, 2020: 2Apr 8, 2021: 4Apr 20, 2022: 8Apr 20, 2023: 0Apr 16, 2024: 0Apr 3, 2025: 4Apr 21, 2026: 6
May 8, 2014Lower is betterApr 21, 2026

Inspections & violations

Apr 21, 2026 6 demerits · 1 violation
Inspector comments: Night swimming not allowed Flow meter must remain operable. Flow required at 138 gpm to meet turnover and flow restriction of the suction piping.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed a the ring buoy one foot in length longer than the required 42ft. CDI - Buoy rope was shortened.

View this inspection on the county portal ›

Apr 3, 2025 4 demerits · 1 violation
Inspector comments: NOTE: - Flow meter must remain operable and range between 130- 135 GPM. - Night Swimming is NOT Permitted. - Ensure all gauges remain operable at the sand filters tanks. - Ensure to keep all chemical reagents up to date for the season. One container of reagent #2 is expiring soon on 8/25. - Maintenance supervisor: Daniel Brown present during inspection
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs.- Observed one missing weir of five weirs. Item is ordered and on the way to be replace according to CPO.

View this inspection on the county portal ›

Apr 16, 2024 0 demerits · 0 violations
Inspector comments: No violations noted during inspection. Flow meter range confirmed at 135 GPM

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 20, 2023 0 demerits · 0 violations
Inspector comments: CPO Daniel Brown on site during inspection. EHS verified pump, drain covers, confirmed flow meter operable and at 130gpm during inspection. No night swimming at this location. Permit issued.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 20, 2022 8 demerits · 2 violations
Inspector comments: Daniel Brown present during the inspection. Main drains and pumps were confirmed. Confirmed flow meter between 130-135GPM. Permit issued.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed no drain cover/grate inspection on the log sheet. Add as a daily check. CDI- CPO made more copies of the previous log sheet which had all of the requirements for daily/weekly checks.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed 2 doors to the clubhouse not self latching when closed. CDI- CPO corrected and all gates and doors to the pool are self closing and self latching.

View this inspection on the county portal ›

Apr 8, 2021 4 demerits · 1 violation
Inspector comments: Windows for unit that is adjacent to enclosed area with HVAC units with technician access gate should only be limited to opening 4”.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. One manual gate latch did not self-latch. Manual latch was recently installed after a lightning strike fried the badge system. Adjustment made to latch to provide self-latching while on site.

View this inspection on the county portal ›

Apr 28, 2020 2 demerits · 1 violation
Inspector comments: Issuance of a permit by this department does not negate closure required by Executive Order No. 120 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order. Pool is not open for night swimming. Night swimming visit is not required. Operator stated that pool will be open from dawn to dusk. Currently pool sign states that pool is open until 10pm. Sign will be changed.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(i) Water in restrooms shall not exceed 110 F. Water in men's room @ 120F. .2526(k) Provide shatterproof mirrors. Mirrors in both restrooms not shatterproof.

View this inspection on the county portal ›

May 1, 2019 6 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris in one skimmer basket. Corrected during inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed loose recess latter. Tghtened during inspection.

View this inspection on the county portal ›

Apr 3, 2018 6 demerits · 2 violations
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter not operating. CDI-repaired.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed vent not operating in chemical room.

View this inspection on the county portal ›

Apr 27, 2017 2 demerits · 1 violation
Inspector comments: PDSC sheet was correct. The 2 doors closest to the office are always locked per Larry Talbert.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed a loose ladder.

View this inspection on the county portal ›

Apr 8, 2016 4 demerits · 1 violation
Inspector comments: Pool passed pre-inspection pending approval of updated forms for pump and main drain grates. Report received by Larry Talbert.
#18 · Premises: lifeguards present or warning signs posted −4
Verbage not correct and letter size incorrect, new sign posted during inpsection

View this inspection on the county portal ›

Apr 16, 2015 8 demerits · 2 violations
Inspector comments: 15. Rope length corrected to 42 ft, flipped direction of wing nuts to prevent injury Inspecction report received by Larry Talbert Pool pass pre-inspection
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Vacuum port covered with wrong cover-replaced during inspection
#27 · Equipment room: filter backwash discharged through an air gap −2
2" Air gap required on backwash line

View this inspection on the county portal ›

May 8, 2014 18 demerits · 4 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed body hook disassembled from pole. CDI-hook attached. Keep body hook assembled.
#22 · Premises: emergency telephone provided −6
Emergency phone number posted is incorrect. CDI-correct number posted.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter not operating. Repair.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed soda ash stored on floor, bag torn and ash spilling onto floor. Store chemicals off floor.

View this inspection on the county portal ›