‹ Back to search

10demerits

HUNTINGTON RIDGE TOWNHOMES

4495 PANTHER PLACE, Charlotte, NC 28269
Seasonal Swimming Pool · NC permit/State ID 2060500777
Latest result10 demerits
Last inspectedMay 12, 2026
Inspections on record13
On record sinceApr 8, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01122 Apr 8, 2014: 8Apr 29, 2015: 4Apr 19, 2016: 10Apr 20, 2017: 6Apr 4, 2018: 10Apr 4, 2019: 22Apr 27, 2020: 6Apr 30, 2021: 8Apr 21, 2022: 12Apr 5, 2023: 4May 3, 2024: 6May 1, 2025: 6May 12, 2026: 10
Apr 8, 2014Lower is betterMay 12, 2026

Inspections & violations

May 12, 2026 10 demerits · 2 violations
Inspector comments: EHS verified that all of the following items were compliant: 1.) Flow meter must remain operable. VFD installed. Flow required at 145 gpm to 227 gpm to meet turnover and flow restriction of the return pipe flow. 2.) New Pump Hayward HCP30703, 7 3.) FlowVis flow meter reading in the range of the above flow restriction. 4.) 4” main drain line; 3” return and skimmer lines 5.) (2) Aquastar WAV12WRxxx 2017 drain covers. 6.) (8) total skimmers (1) plugged in skimmer and disabled on wall. (7) with Aquastar 6HPHAxxx 2017 equalizer line covers. 7.) New Filters (2) Pentair TR140C filters 8.) 16 returns, either on the wall or the floor. Night swimming is not permitted.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope for buoy greater than 50 feet. -CDI- Rope was cut to 50 feet.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed a chair 5 feet from the edge of the pool. -CDI- Chair was moved back to 6 feet.

View this inspection on the county portal ›

May 1, 2025 6 demerits · 1 violation
Inspector comments: One equalizer is disabled and plugged. Not approved for night swimming.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed phone number posted on sign does not match what 911 has and what is written on the phone receiver. CDI PIC corrected the number on the sign.

View this inspection on the county portal ›

May 3, 2024 6 demerits · 1 violation
Inspector comments: Pool is open for 2024 season, no Nightswimming permit.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Rope was 58 feet long. Operator cut the rope to the required length of 50 corrected

View this inspection on the county portal ›

Apr 5, 2023 4 demerits · 1 violation
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed debris in pool floor.

View this inspection on the county portal ›

Apr 21, 2022 12 demerits · 3 violations
Inspector comments: Pools PH was 6.8, they fixed and it was 7.2 by the end of the inspection
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed light loose and coming off the wall. PO added a screw and it was stable by the end of the inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010). Observed only 39" between the outside fence horizontals. The pool is pre 2010
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. .2530(c) Provide "Adults should not swim alone." in 1" lettering. Observed sign with only 1/2 lettering. CDI-PO provided a sign with the correct 1" signage

View this inspection on the county portal ›

Apr 30, 2021 8 demerits · 2 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed pool debris. **.2537(14) Keep pool surface and pool floor free of debris.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed skimmer baskets with debris. **.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.

View this inspection on the county portal ›

Apr 27, 2020 6 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Debris inside of skimmer.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. - Rubber bumper missing from ladder. Benji Sheehan was present during inspection.

View this inspection on the county portal ›

Apr 4, 2019 22 demerits · 5 violations
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. At start of inspection pH measured 6.8. By end of inspection it had been corrected to 7.4.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537 Keep pool floor in good repair and free of debris. Observed some worn spots on floor of pool. Observed some leaf debris on floor of pool.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed pollen and leaves in pool and skimmer baskets. Cleaned during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Observed two areas in fence where uprights had been bent apart to 5" and 6". Repaired to be 4" gap during inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed old open hole on deck. It was filled with pool putty during inspection. .2537(2) Decks shall be kept in good repair. Observed cracked decking in one corner and wide crack near one ladder. Both repaired with pool putty during inspection.

View this inspection on the county portal ›

Apr 4, 2018 10 demerits · 2 violations
Inspector comments: No points were issued: 8. Missing weir in one of the skimmers. Weir was replaced. .2518
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed debris on the pool's floor. Needs to be cleaned. .2537
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Rope length was 37fft but due to width was required 50ft. Rope was replaced. Buoy was damaged. Buoy was replaced. .2530

View this inspection on the county portal ›

Apr 20, 2017 6 demerits · 2 violations
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed a few areas of fencing not 48" due to landscaping. Fence needs to be 48" min.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Ceiling damage in women's restroom needs some repair.

View this inspection on the county portal ›

Apr 19, 2016 10 demerits · 3 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed pool needing vacuuming due to debris build up on pool floor and walls. Observed a couple pool tiles separating from poolwall and degraded concrete coping above pool wall at ends of the pool, needs repair.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Deep end pool ladder on Right side needs safety end cap at wall installe
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed a few areas of fencing not 48" due to landscaping. Fence needs to be 48" minGENERAL COMMENT: Inspection took place on 4/12/16, form had to be re-submitted due to error of inspection listed as a visit. Corrected PDSC form has been received, permit to be issued.

View this inspection on the county portal ›

Apr 29, 2015 4 demerits · 1 violation
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Maintain skimmer baskets clean. Observed debris in the skimmer baskets.

View this inspection on the county portal ›

Apr 8, 2014 8 demerits · 4 violations
Inspector comments: Inspection report received by Mark Houff
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemical room needs natural cross or continuous forced ventillation
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Direction of flow marked on pipes during inspection
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Loose toilet in women's restroom, mirrors to be of shatterproof construction, soap needed in both restrooms
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Hose bibs need backflow preventers installed

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “HUNTINGTON RIDGE TOWNHOMES” or State ID 2060500777). Inspection type (routine vs. follow-up) is not published in the county's data.