OLDE SYCAMORE

7831 OLDE SYCAMORE DR, Charlotte, NC 28227
Seasonal Swimming Pool · NC permit/State ID 2060500795
Latest result4 demerits
Last inspectedApr 23, 2026
Inspections on record14
On record sinceJun 3, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01122 Jun 3, 2014: 12Jun 22, 2015: 16Jun 9, 2016: 22May 31, 2017: 18May 10, 2018: 20May 10, 2019: 4May 6, 2020: 8Apr 15, 2021: 16Apr 22, 2022: 12Apr 19, 2023: 12May 8, 2024: 8May 9, 2024: 4Apr 15, 2025: 12Apr 23, 2026: 4
Jun 3, 2014Lower is betterApr 23, 2026

Inspections & violations

Apr 23, 2026 4 demerits · 1 violation
Inspector comments: No night swimming. Ensure electrical conduit foothold outside back fence becomes inaccessible.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Slightly debris on pool floor

View this inspection on the county portal ›

Apr 15, 2025 12 demerits · 3 violations
Inspector comments: Permit restriction: 11 of 12 skimmers functioning, one plugged. Pool is permitted to continue operation until a clarity issue occurs.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Surface and floor with some debris. Clean
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Surface skimmers shall be installed per manufacturer's instructions. Observed 11 of 12 functioning skimmers. One skimmer at 5 foot depth marker, has both pipes plugged. Operator states has been this way for 3 years. Permit restriction going forward: 11 OF 12 SKIMMERS FUNCTIONING, ONE PLUGGED. POOL IS PERMITTED TO CONTINUE OPERATION UNTIL A CLARITY ISSUE OCCURS.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Observed one door not self latching, self closing or with functioning alarm. Operator repaired alarm and alarm functioned properly.

View this inspection on the county portal ›

May 9, 2024 4 demerits · 1 violation
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed no recordings in log book

View this inspection on the county portal ›

May 8, 2024 8 demerits · 2 violations
Inspector comments: Call 980-314-1620 for reinspection
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed no recordings in log book
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Observed doors not self closing self latching and not alarmed .2537(b) All gates and doors shall be self-closing, self-latching. Observed back gate not self closing self latching. One door not checked and one gate not checked (far side of pump room). Check these for self-closing self latching before reinspection.

View this inspection on the county portal ›

Apr 19, 2023 12 demerits · 2 violations
#3 · Water quality: pool water pH −6
Ph was raised to 7.2 during inspection
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Hydro stat cover was missing screw and corrected during inspection

View this inspection on the county portal ›

Apr 22, 2022 12 demerits · 3 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris.- Observed pool floor and drain covers with leaf debris. EHS able to see and verify main drains.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Observed leafs and debris in skimmers.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Observed clubhouse door that opens to the pool deck that was not self closing. CDI audible alarm added.

View this inspection on the county portal ›

Apr 15, 2021 16 demerits · 4 violations
Inspector comments: CPO Pat was present during the inspection. No night swimming is permitted for the pool until the regulatory authority makes another visit to approve the night swimming.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris.- Observed pool floor with leaf debris. EHS able to see and verify main drains. CDI- PIC cleaned pool floor during inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Observed leaf debris in skimmers. CDI- CPO cleaned skimmers.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. - Observed no ring buoy and throw rope available. CDI- CPO provided 50ft throw rope with buoy.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
.2526(d) Provide hose bib with back flow prevention device. - Observed no back flow prevention device on hose bibs.

View this inspection on the county portal ›

May 6, 2020 8 demerits · 3 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Remove leaves and debris from skimmer baskets.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(6) Provide sufficient lighting in chemical storage room. Lights blown out in chemical room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. Provide shatterproof mirrors in restrooms.

View this inspection on the county portal ›

May 10, 2019 4 demerits · 1 violation
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Clean skimmers and fix 3 weirs that came off. They was fixed during inspection

View this inspection on the county portal ›

May 10, 2018 20 demerits · 4 violations
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed initial pH reading at 7.0. CDI- corrected to 7.2.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed throw rope connected to ring buoy at 40 feet. CDI- corrected to 50 feet.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed 6 and 1/4 underneath the gate located nearest to the grills. CDI- barrier was added to bottom of gate to correct this.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed 2 holes in pool deck that were 1 and 3/4 inches wide. CDI- plugged during inspection.

View this inspection on the county portal ›

May 31, 2017 18 demerits · 5 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
one weir is broken and needs to be fixed
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
handrail was lose but was corrected during inspection
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
fitting was missing cap but was corrected during inspection
#22 · Premises: emergency telephone provided −6
phone missing address and number but was corrected during inspection
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
woman's bathroom door in stall needs to be fixed

View this inspection on the county portal ›

Jun 9, 2016 22 demerits · 5 violations
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Observed the vacuum on and no approved vacuum cap was on the port. Vacuum turned off today. This vacuum port must have a protective cap. Recommended is a cap that needs a tool to open it up. Repair this within 30 days. Intent issued for this item today.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 3 weirs missing today.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed loose handrails and ladders today.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed the door to the pool house not self latching. Correct this within 30 days. Intent to suspend issued today for this violation.
#22 · Premises: emergency telephone provided −6
Observed no address and the incorrect phone number listed on the phone today- changed durinig the inspection to correct.

View this inspection on the county portal ›

Jun 22, 2015 16 demerits · 4 violations
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Vacuum port not covered. Corrected during inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Missing 5 of 12 weirs. Replace.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ensure that all ladders and handrails are secure.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Ensure that flow meter is functioning properly.

View this inspection on the county portal ›

Jun 3, 2014 12 demerits · 3 violations
Inspector comments: Chris Rogers present.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 2 missing weirs. CDI - replaced
#22 · Premises: emergency telephone provided −6
Observed no address and phone number on the emergency phone sign. CDI - address and phone number was posted.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Observed no labels on pipes/valves. CDI - pipes/valves were labeled during the inspection.

View this inspection on the county portal ›