‹ Back to search

22demerits

SENIOR VILLAGE

1705 QUEEN CITY DR, Charlotte, NC 28208
Seasonal Swimming Pool · NC permit/State ID 2060500801
Latest result22 demerits
Last inspectedMay 11, 2022
Inspections on record10
On record sinceJul 25, 2013

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

02244 Jul 25, 2013: 4Jul 15, 2014: 26Jun 12, 2015: 44Jul 14, 2016: 0May 24, 2017: 8May 21, 2018: 34May 14, 2019: 4Apr 15, 2020: 2May 11, 2021: 8May 11, 2022: 22
Jul 25, 2013Lower is betterMay 11, 2022

Inspections & violations

May 11, 2022 22 demerits · 5 violations
Inspector comments: Pool operating hours are from 9am - 7pm Monday - Sunday therefore night swimming visit is not required. Night swimming is not permitted at this time.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed debris in pool from pollen. Observed some areas in bottom of pool cracking/paint peeling. CDI: CPO working on cleaning pool.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(c) Depth markers shall include the word "feet" or symbol "ft". Some dept markers “ft” symbols on 3 1/2 and 5 1/2 markers are starting to fade. CPO stated that markers will be redone by next pool season.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope length > 45ft. CDI: rope was cut to 45ft by CPO during inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
REPEAT VIOLATION: .2537(2) Decks shall be kept in good repair. Repair small cracks in pool deck.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. Observed this warning sign not exact wording. CDI: CPO made up a temporary sign with exact wording during inspection to meet compliance. Original pool sign faded and got sun damaged through the winter.

View this inspection on the county portal ›

May 11, 2021 8 demerits · 2 violations
Inspector comments: 11. Tighten handrail at shallow end of pool (appear to be loose). No night swimming permitted 60 GPM Issuance of permit by this Department does not negate meeting requirements of Executive Order 195 or subsequent Orders in effect unless such Orders are rescinded or superseded by another appilcable Order.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed skimmer weir that is not working properly. Replace weir.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Repair small cracks in pool deck. Observed weeds and other plants growing through crack on pool deck.

View this inspection on the county portal ›

Apr 15, 2020 2 demerits · 1 violation
Inspector comments: 85 GPM Pool is not permitted for night swimming. Facility understands that although the pool is permitted, it will not open until Mecklenburg County and the State of NC declares it to be safe to do so.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521(a) Steps or ladders shall be provided every 75 ft along the shallow area perimeter. Greater than 75 feet between steps and ladders in pool.

View this inspection on the county portal ›

May 14, 2019 4 demerits · 2 violations
Inspector comments: Pool is not permitted for night swimming. Repair static on phone. Connnection was clear enough on both ends to be heard. However, removal of static will help in case of emergencies.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521(a) Steps or ladders shall be provided every 75 ft along the shallow area perimeter. Greater than 75 feet between steps and ladders in pool. Also, affix ladder properly to deck of pool. CDI.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Provide air gap for discharge.

View this inspection on the county portal ›

May 21, 2018 34 demerits · 10 violations
Inspector comments: 10" round cover installed on 12"x12" adapter plate. Appears to be OK per Aquastars's sump requirements. Pump motor bonded to electrical ground. Ensure pump motor is properly bonded to the pool. Pull all required permits. Ensure that floats on safety rope are maintained to be spaced no more than 5 feet apart. New PDSC form filled out and approved to reflect Pentair Challenger CHII-NI-2FE pump (appears to be existing) and sump dimensions for sump. Permit issued. Local permit ID#18-600048 Night swimming is not permitted.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No recording calcium hardness instead of cyanuric acid. Check daily Cl, pH, Main Drains and pool maintenance activities. Check at least weekly Total Alkalinity and Cyanuric Acid. Operator tested CYA at 40ppm.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Weir not installed in far weir. Install functional weirs. Water level above skimmers. Maintain proper water level for functional skimmers. Corrected by operator.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
>75 feet between steps and ladder. Provide ladders and steps no more than 75 feet apart.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy damaged. Replaced by operator.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Back gate not self-latching, < 48" high. Corrected by operator.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Covered canopy too close to the pool. Maintain at least 6 feet clear walkway around the pool. Corrected by operator.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Provide spare pump basket. Corrected by operator.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Leak at pump. Fix leak. Dry chemicals stored on the ground in the pump room. Store on a shelf, pallet or in a bucket.
#27 · Equipment room: filter backwash discharged through an air gap −2
Back wash a direct connection. Provide air gap for backwash.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Provide signage directing bathers to shower before entering the pool.

View this inspection on the county portal ›

May 24, 2017 8 demerits · 3 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Clean, resurface, repaint pool floor and wall by next swimming pool season.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Tightly secure loose railing at steps and ladder in swimming pool.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Provide back flow prevention device on hose bib on pool deck.

View this inspection on the county portal ›

Jul 14, 2016 0 demerits · 0 violations

No violations were recorded for this inspection.

View this inspection on the county portal ›

Jun 12, 2015 44 demerits · 11 violations
Inspector comments: Immediate suspension issued.3)15)22)Contact Will Harrison 704-336-5528 for reinspection once issues have been corrected.
#3 · Water quality: pool water pH −6
pH < 6.8. Maintain between 7.2 and 7.8.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Records last checked 6-8-15. Check daily Cl, pH and drain covers. No Total Alkalinity or Cyanuric Acid checks. Check at least weekly.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Paint on pool walls and floor peeling. Maintain walls and floor in good condition.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Water level below the skimmers. Skimmers not functioning. Maintain proper water level in the pool.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder and handrail loose. Maintain in good condition.
#13 · Pool maintenance: contrasting band on steps and benches −4
Contrasting color band peeling. Provide 2 inch contrasting color band on steps.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy worn, throw rope frayed in places. Provide US Coast Guard approved ring buoy with a 45 foot throw rope.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Back gate not self-latching. Gates shall be self-closing and self-latching.
#22 · Premises: emergency telephone provided −6
Emergency phone shares the same line as the front desk. Phone shall be a dedicated line that connects directly to 911.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Label all pipes in pump room.
#27 · Equipment room: filter backwash discharged through an air gap −2
Backwash not discharged through an air gap. Provide air gap for backwash.

View this inspection on the county portal ›

Jul 15, 2014 26 demerits · 7 violations
Inspector comments: #5 Pool records not available - reported to be in manager's locked office. **Keep records available. Permit action to be taken if not available @ return. GC #26 Re-label circulation system pipes. (faded). GC #30 Install vacuum breaker on hose bib in equipment/ chemical room. Intent to suspend issued for #8, #9, #18, & #24.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One (of 2) weirs missing part. **replace this weir.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Deck depth markers 3" in height. **minimum 4" required (w/ the exception of FT).
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Handrail loose. **secure.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Rope 55' on ring buoy. **rope shortened to 45'.
#18 · Premises: lifeguards present or warning signs posted −4
Lack sign stating the exact words "CHILDREN SHOULD NOT USE THE SWIMMING POOL WITHOUT ADULT SUPERVISION" "ADULTS SHOULD NOT SWIM ALONE". Letters must be at least 1" in height.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Operable flow meter located on line before filter. **relocate to filtered water line.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Lights inoperable in equipment/ chemical room. **repair/ replace.

View this inspection on the county portal ›

Jul 25, 2013 4 demerits · 1 violation
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “SENIOR VILLAGE” or State ID 2060500801). Inspection type (routine vs. follow-up) is not published in the county's data.