COMFORT SUITES-UNCC

7735 UNIVERSITY CITY BV, Charlotte, NC 28213
Seasonal Swimming Pool · NC permit/State ID 2060500812
Latest result10 demerits
Last inspectedMay 18, 2026
Inspections on record13
On record sinceMay 23, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01836 May 23, 2014: 14May 12, 2015: 22Jun 1, 2016: 28May 17, 2017: 10May 24, 2018: 0May 17, 2019: 4Jun 28, 2022: 6Jun 6, 2023: 26Jun 27, 2024: 4Sep 25, 2024: 36Jul 22, 2025: 16Sep 5, 2025: 0May 18, 2026: 10
May 23, 2014Lower is betterMay 18, 2026

Inspections & violations

May 18, 2026 10 demerits · 2 violations
Inspector comments: Not approved for night swimming. Pool deck multiple trip hazards patched during the inspection today.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed loungers within 6 ft of the pool. CDI CPO moved furniture . .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed trip hazards greater then 1/2 on the pool deck ( around the skimmer basket, pool deck boarder, no diving signs, and a few holes in the pool deck. CDI PIC repaired trip hazards with a quick cement.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Observed the emergency phone had no dial tone and could not call 911. CPO repaired the emergency phone during the inspection.

View this inspection on the county portal ›

Sep 5, 2025 0 demerits · 0 violations
Inspector comments: Inspection conducted with Ronald Rankin. No night swimming. NEW CPO: Ronald Rankin (980) 228-6640 ronaldrankin45@gmail.com

No violations were recorded for this inspection.

View this inspection on the county portal ›

Jul 22, 2025 16 demerits · 3 violations
Inspector comments: Permit denied. See report for details. Inspection conducted with Ronald Rankin. No night swimming. NEW CPO: Ronald Rankin (980) 228-6640 ronaldrankin45@gmail.com
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2537(7) Drain covers shall be in good condition and securely attached. Equalizer cover is not fully secured to wall. Gap between equalizer cover and wall at the bottom of the equalizer and equalizer can be moved. Secure equalizer to wall.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Posted phone number at emergency phone does not call back to emergency phone.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter not operational. .2518(e) Provide a spare basket for pump. No spare basket for pump.

View this inspection on the county portal ›

Sep 25, 2024 36 demerits · 10 violations
Inspector comments: Robin Vansickle present during the inspection. Acting CPO. CPO must make daily site visits for pool to be open. No staff onsite with CPO certification. Do not open pool to public of daily site visit does not occur. Permit issued for no night swimming. All permit items from previous site visit corrected.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Cyanuric acid lowered to 100 ppm from previous site visit. Continue to lower. CYA at max level permitted.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some staining on pool floor. Keep floor at >50% light reflectance.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Minor damage to skimmer basket closest to the steps. Replace skimmer basket.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
One no diving marker not attached. Reattached during the site visit. One cracked depth marker at 3 ft. Still secure. Monitor and replace if not secure.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy grab rope degraded. New ring buoy was provided during the site visit.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
No flow meter on chlorinator. Original construction. Install with flow meter per NSF approval if replaced. Small leak at chlorinator. Repair leak.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter not installed per mfg. instructions. Old style flow meter requires 10xpipe diameter on inlet and 4xpipe diameter on outlet. If replaced, install per mfg. instructions. No permit restrictions or flow restrictions. No spare pump basket for pump. Provide spare basket.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Pump room floor wet due to leak at chlorinator. Keep dry.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water in restrooms >116 F. Maintain at 110 F or below. One stall locked in women's restroom. Toilet in need of cleaning. Keep fixtures accessible and clean.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
No hose bib in restrooms. Original construction. Provide hose bib in restrooms.

View this inspection on the county portal ›

Jun 27, 2024 4 demerits · 1 violation
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmers in need of cleaning.

View this inspection on the county portal ›

Jun 6, 2023 26 demerits · 6 violations
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 8.4. Lower pH
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Observed expired covers removed no new PDCS form provided or approved by the department. .2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7. Observed equalizer removed from pool without replacement or filling. Holes from removal are still there.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmers in need of cleaning.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(d) The distance between no diving markers shall be no more than 25 feet perimeter or as the crow flies. Observed no diving marker placed more that 25ft apart.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Observed several cracks on pool deck.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. Observed cover stored on piping. Create space for items.

View this inspection on the county portal ›

Jun 28, 2022 6 demerits · 1 violation
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope measuring at 32 feet. Corrected during inspection to 30 feet which is the rope length printed on EHS field book.

View this inspection on the county portal ›

May 17, 2019 4 demerits · 1 violation
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter not operating. Needs to be repaired. **.2518(g) Keep flow meter operational.

View this inspection on the county portal ›

May 24, 2018 0 demerits · 0 violations
Inspector comments: All violations corrected from last visit. No violations noted. Permit Issued. no. 18-600538

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 17, 2017 10 demerits · 2 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed rope connected to ring buoy at 32 feet 8 inches. Rope was cut to 30 feet. Maintain rope at 30 feet.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed stuck flow meter. Maintain flow meter in good repair.

View this inspection on the county portal ›

Jun 1, 2016 28 demerits · 6 violations
#2 · Water quality: disinfectant residual provided by −6
Maintain disinfectant at a minimum of 1.0ppm. Observed at 0.4 ppm (immediate suspension item).
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Maintain surface skimmers clean and in good repair. Observed all weirs missing (intent to suspend item). Observed debris inside the skimmer baskets.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Maintain ladders in good repair. Observed loose ladder (tightened while onsite).
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Provide throw rope in good repair. Observed throw rope worn and shredded to a thin string 2.5 feet from handle (immediate suspension).
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Maintain the fence in good repair. Observed a broken slat near the parking lot area allowing for an 8 inch gap at the top (intent to suspend item).
#22 · Premises: emergency telephone provided −6
Provide a sign posted at the emergency telephone with the location phone number. Observed phone number posted not matching 911 reported number.

View this inspection on the county portal ›

May 12, 2015 22 demerits · 5 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Keep walls of pool clean and pool clear of debris. Observed debris in pool
#13 · Pool maintenance: contrasting band on steps and benches −4
Observed contrasting band on pool steps to be more than 1" from step edge in some areas. This item must be corrected within a year. Failure to do so will likely result in this pool receiving no permit in 2016 or until corrected.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed some chairs within 6' of pool edge. CDI- items moved away from pool edge.
#22 · Premises: emergency telephone provided −6
Observed two different phone numbers in phone box. Verified correct phone # with 911, and removed incorrect number.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter not working. Operator re[placed while on site with functioning flow meter.

View this inspection on the county portal ›

May 23, 2014 14 demerits · 5 violations
Inspector comments: #5 Record daily maintenance on log sheet (ie backwash) Report received by DJ Jinwala
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
No Diving markers exceed 25 ft between markers - Intent to Suspend issued
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Tighten ladder down
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter does not appear to be working
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Natural cross or continuous forced ventilation required
#27 · Equipment room: filter backwash discharged through an air gap −2
Back wash line must be plumbed to sanitary sewer with a 2" air gap

View this inspection on the county portal ›