‹ Back to search

16demerits

BONNIE BRIAR CONDOS

9338 BONNIE BRIAR CR., Charlotte, NC 28277
Seasonal Swimming Pool · NC permit/State ID 2060500831
Latest result16 demerits
Last inspectedApr 13, 2026
Inspections on record13
On record sinceMay 16, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0816 May 16, 2014: 12Apr 16, 2015: 12Apr 27, 2016: 2Apr 25, 2017: 10Apr 10, 2018: 14Apr 24, 2019: 0Apr 8, 2020: 6Apr 16, 2021: 10Apr 29, 2022: 8Apr 21, 2023: 2Apr 16, 2024: 2Apr 22, 2025: 2Apr 13, 2026: 16
May 16, 2014Lower is betterApr 13, 2026

Inspections & violations

Apr 13, 2026 16 demerits · 4 violations
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine less than 1.0ppm. -CDI- CPO corrected to 1.0ppm.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris in skimmer baskets.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed less than 6ft clearance around pool. -CDI- CPO corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(b) Provide sufficient lighting in pump room. Observed no lighting in pump room.

View this inspection on the county portal ›

Apr 22, 2025 2 demerits · 1 violation
Inspector comments: -PDSC Verified -Pump flow shall not exceed 150GMP. -No night swimming
#27 · Equipment room: filter backwash discharged through an air gap −2
REPEAT. .2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap at backwash pit in pump room.

View this inspection on the county portal ›

Apr 16, 2024 2 demerits · 1 violation
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap in backwash.

View this inspection on the county portal ›

Apr 21, 2023 2 demerits · 1 violation
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. No air gap between bottom of backwash pipe and pit. Provide air gap.

View this inspection on the county portal ›

Apr 29, 2022 8 demerits · 2 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Rope attached to ring buoy was 47 feet. CDI - Operator cut rope to 38 feet during inspection.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. No air gap between bottom of backwash pipe and pit. Provide air gap.

View this inspection on the county portal ›

Apr 16, 2021 10 demerits · 2 violations
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH level at 7.1. Corrected during inspection to 7.2.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Observed all chemicals in testing kit expired in 2019 due to pool not opening in 2020. PO is providing new testing kit.

View this inspection on the county portal ›

Apr 8, 2020 6 demerits · 2 violations
Inspector comments: PDSC information verified in-field. No signature due to COVID-19.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. Observed sign with 3 and 1/2 inch lettering. CDI- sign replaced.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed backwash through air break not air gap.

View this inspection on the county portal ›

Apr 24, 2019 0 demerits · 0 violations
Inspector comments: No violations observed today. Ensure that permit remains visible. Night swimming is not permitted at this pool. ** CPO unable to to sign due to set of afternoon appointments conflicts.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 10, 2018 14 demerits · 3 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris in baskets. CDI Operator cleaned out baskets.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Rope was greater than 38 feet. CDI Operator cut to 38 feet.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed lawn chairs and table setting less than 6 feet. CDI Operator relocated.

View this inspection on the county portal ›

Apr 25, 2017 10 demerits · 3 violations
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed fence less than 48 inches from outside approach due to landscaping.
#19 · Premises: signs prohibit glass containers or pets in pool area −4
Observed no shower before entering pool signs. CDI
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Observed pipes that needed remarking in pump room. CDI Need an updated PDSC form before permit can be issued. Pentair challenger CHII-N1-3F 3Hp, Waterway 640-472x, Aquastar 6HP

View this inspection on the county portal ›

Apr 27, 2016 2 demerits · 1 violation
Inspector comments: 8. .2537 Keep Skimmers clean and in good repair. Observed skimmers with debris.Permit will be posted online once available.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533 Atleast 3 ft clearance in the equipment room. Observed less then 3 feet clearance in equipment room.

View this inspection on the county portal ›

Apr 16, 2015 12 demerits · 3 violations
#1 · Water quality: water clear enough to clearly see bottom of pool and pool drain −6
Observed pool water too cloudy at start of inspection - could not see main drains clearly. left to inspect three other pools with same operator, then returned after water had cleared. Was able to see pool drains clearly.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris in the skimmer baskets.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed vent and motorized fan in chemical room. Fan turns off when lights turn off. CPO called for repair.

View this inspection on the county portal ›

May 16, 2014 12 demerits · 3 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Clean pool floor
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Clean skimmer baskets
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck corrected during inspection.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “BONNIE BRIAR CONDOS” or State ID 2060500831). Inspection type (routine vs. follow-up) is not published in the county's data.