Seasonal Swimming Pool · NC permit/State ID 2060500834
Latest result2 demerits
Last inspectedMay 22, 2026
Inspections on record16
On record sinceJul 2, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jul 2, 2014Lower is betterMay 22, 2026
Inspections & violations
May 22, 2026 2 demerits · 1 violation
Inspector comments: PERMIT RESTRICTIONS:
- Flow meter must remain operational. Flow shall not exceed 150 GPM due to drain Cover Flow restriction. Suction Hazard.
- Night Swimming is NOT permitted.
- CPO: Harold Marroquin present during permit inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521(b) Ladders shall have slip-resistant tread.- Observed one step of ladder is missing slip-resistant tread. Need replacement.
May 20, 2026 6 demerits · 1 violation
Inspector comments: PERMIT RESTRICTIONS:
- Flow meter must remain operational. Flow shall not exceed 150 GPM due to drain Cover Flow restriction. Suction Hazard.
- Night Swimming is NOT permitted.
NOTE:
- This pool ID# 500834 permit denied today due to following noted items on the inspection sheet.
- The item shall be repaired, and ensure it is in good working before scheduling re-inspection.
- Please Contact the department office at 980-314-1620 to request and pay for the return visit prior to re-inspection. The return
inspection fee is $100.
- If you have any questions call EHS: 704-617-9777 or email to obtain the operational permit.
- The pool shall remain closed until permit is issued.
- CPO: Harold Marroquin present during permit inspection.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable.- Observed Kings III phone is not working when pushing a button to call 911. The machine stated “Exceeded maximum call count, calling disable, time remaining 24 hours.” The machine needs repair.
May 12, 2026 16 demerits · 4 violations
Inspector comments: PERMIT RESTRICTIONS:
- Flow meter must remain operational. Flow shall not exceed 150 GPM due to drain Cover Flow restriction. Suction Hazard.
- Night Swimming is NOT permitted.
NOTE:
- This pool ID# 500834 permit denied today due to following noted items on the inspection sheet.
- All items shall be repaired/replaced, and ensure it is in good working condition before scheduling re-inspection.
- Please Contact the department office at 980-314-1620 to request and pay for the return visit prior to re-inspection. The return inspection fee is $100.
- If you have any questions call EHS: 704-617-9777 or email to obtain the operational permit.
- The pool shall remain closed until permit is issued.
- 911 Emergency call verified the physical address of this pool is 6225 Hackberry Creek Trail, NOT 6455 Hackberry creek trail.
- CPO: Harold Marroquin present during permit inspection.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity.- Observed the facility with an expired chemical test kit. Obtain a new up to date chemical test kit.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Pole for body hook must be non-telescoping, non-adjustable, and non-collapsible.- Observed the body hook with collapsible pole. The body hook must be at least 12ft long non adjustable/ non collapsible pole.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.- Observed more than 1/2” deep of disrepair caulking all around the pool, uneven ground of concrete and wood strips (disrepair) between concrete deck surfaces within 6ft to 8ft required deck space. Repair needed.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(a) Post a shower sign visible upon entrance to the pool.- Observed the facility without a shower sign. Obtain one and post at the front entrance.
May 7, 2025 12 demerits · 2 violations
Inspector comments: EHS walked with CPO Alex (aka Harold) Meet all restrictions ,flow meter didn’t exceed 150. Permit was issued. No night swimming.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope was 7 inches too short. CDI..Rope was changed out to meet rope length
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed incorrect address on sign, Also observed couldn’t make out one number in phone number on sign. CDI..Address was phone was updated on sign
Jul 3, 2024 18 demerits · 5 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. - Observed bottom of pool with debris. CDI- CPO started to clean leaf debris form pool floor during the inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Observed debris in skimmer baskets. CDI- CPO cleaned skimmer baskets.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Pool sign had wrong address posted. CDI- PIC provided correct address on pool emergency phone sign.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. - Observed standing water in pump room. No pipes leaking.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. - CPO unable to provide documentation of mirror being shatterproof.
.2526(l) Provide toilet paper and dispensers in restrooms. - Observed no toilet paper in restroom.
May 16, 2023 0 demerits · 0 violations
Inspector comments: No violations observed today
No violations were recorded for this inspection.
May 12, 2023 16 demerits · 4 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmer baskets with large amount of debris.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. Observed 2 gates not self-latching. Corrected during inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed 2 areas on left side of pool deck with missing wood creating offsets more than 1 inch. Corrected during inspection.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
.2543(6) Automatic chemical controllers shall be provided to monitor and adjust disinfectant and pH for interactive play features. Observed chlorine pucks in 1 skimmer basket. Operator removed pucks from skimmer bucket. EHS has to revisit to verify chlorine.
Jun 17, 2022 0 demerits · 0 violations
Inspector comments: No permit restrictions for flow.
No violations were recorded for this inspection.
Jun 10, 2021 10 demerits · 3 violations
Inspector comments: Night swimming is not permitted. Call for night swimming inspection if needed. 980-721-2060
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Two baskets needed to be cleaned out. Keep baskets clean. Corrected during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
One gate not functioning. Permanently fixed by screwing in metal plate. Keep any gate self closing self latching.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Mirror in bathroom is not shatterproof.
Apr 24, 2020 6 demerits · 2 violations
Inspector comments: Due to COVID19 pandemic no signature occurred.
CPO Randy Lundquist was present during inspection.
Permit Conditions inserted on permit.
“issuance of a permit by this department does not negate closure required by Executive Order No. 120 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.”
Night swimming not approved until return visit occurs for approval.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. - observed flow meter malfunctioning and nonfunctional at the start of the inspection. CDI- EHS observed functioning flow meter at the end of the inspection.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2626(k) Provide shatterproof mirrors. - in the restrooms mirrors could not be verified to be shatterproof.
May 13, 2019 6 demerits · 2 violations
Inspector comments: Verified PDSC form was correct with updated information for the 2019 expired main drains.
Approved for night swimming based on previous operating year visit.
Randy Lundquist present for inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed one equalizer line/skimmer blocked such that it was not functioning. Repaired by operator during inspection.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed non shatterproof mirrors in the restrooms.
May 3, 2018 8 demerits · 2 violations
Inspector comments: PDSC information verified and correct. Facility would like night swimming; a follow up visit to verify lighting will be made.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed loose beckets on the ring buoy. The beckets had come unglued and were sliding around. CDI (corrected during inspection) - A new USCG approved buoy was provided.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed non shatterproof mirrors in the restrooms.
Jun 27, 2017 8 demerits · 2 violations
#22 · Premises: emergency telephone provided −6
observed incorrect address and telephone number posted at emergency phone. CDI
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
restroom mirrors are not shatterproof.
May 3, 2016 16 demerits · 5 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
two weirs stuck, not functioning, PO shaved down weirs to operate properly.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Handrail loose at stair entrance to pool. PO tightened handrail.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Body hook only had clip fastener, needs to be bolted. PO installed two bolts to secure the body hook.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemical room exhaust fan in connected to a wall switch, needs to be directly wired for continuos ventilation. PO re-wired fan for continuous ventilation.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Restroom mirrors not shatterproof.GENERAL COMMENT: PERMIT TO BE ISSUED
Apr 15, 2015 4 demerits · 1 violation
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Maintain working flow meter. Observed flow meter not operating but was repaired while onsite.
Jul 2, 2014 6 demerits · 2 violations
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter not working - replace
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Replace lightbulb in chemical room