‹ Back to search

6demerits

BARKLEY PROPERTY OWNERS ASSOC

6429 BARKLEY FARM RD., Huntersville, NC 28078
Seasonal Swimming Pool · NC permit/State ID 2060500836
Latest result6 demerits
Last inspectedApr 14, 2026
Inspections on record13
On record sinceMay 21, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01020 May 21, 2014: 6Apr 15, 2015: 2Apr 13, 2016: 4Apr 21, 2017: 14Apr 13, 2018: 6Apr 23, 2019: 12May 5, 2020: 20Apr 6, 2021: 4May 11, 2022: 0Jun 23, 2023: 0Apr 30, 2024: 0Apr 16, 2025: 16Apr 14, 2026: 6
May 21, 2014Lower is betterApr 14, 2026

Inspections & violations

Apr 14, 2026 6 demerits · 1 violation
Inspector comments: No permit restrictions No night swimming Inspection completed with CPO Chris Andrews
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed throw rope > 38’. CDI: corrected by CPO to 38’ during inspection.

View this inspection on the county portal ›

Apr 16, 2025 16 demerits · 4 violations
Inspector comments: 100 GPM No night swimming permitted. Pool hours will be from dawn to dusk.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed debris on pool floor at time of inspection. CDI
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris in skimmers at time of inspection. CDI
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed two different phone numbers listed on chart for pool phone. Correct numbers was not completely legible at time of inspection. CDI
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(j) Provide soap and soap dispenser, no glass, at each sink. There was not any soap in soap dispenser in men's restroom.

View this inspection on the county portal ›

Apr 30, 2024 0 demerits · 0 violations
Inspector comments: Pool is open for 24 pool season. No night swimming. Zero demrits taken

No violations were recorded for this inspection.

View this inspection on the county portal ›

Jun 23, 2023 0 demerits · 0 violations
Inspector comments: no violations noted

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 11, 2022 0 demerits · 0 violations
Inspector comments: NO VIOLATIONS OBSERVED DURING INSPECTION.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 6, 2021 4 demerits · 2 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Observed handrail loose near the shallow end. CDI-PO tightened handrail
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. Observed wet chemicals over dry. CDI-PO moved dry chemical to a different shelf.

View this inspection on the county portal ›

May 5, 2020 20 demerits · 4 violations
Inspector comments: Inspection conducted with Robert Christman. Due to COVID-19 precautions, inspection was not signed by the operator. Door from restroom to chemical storage room unlocked. Ensure that the public does not have access to pool chemicals. Corrected. NOTE: Lettering on safety signage by emergency phone < 1". Additional signage on pool deck meets requirements. No label on Sta-Rite pump. Pump with 2HP motor. Permit issued. No night swimming. “Issuance of a permit by this department does not negate closure required by Executive Order No. 120 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.”
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Eyeball fitting missing. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. - Corrected.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
New 60 foot throw rope on ring buoy. .2530(a) Provide USCG approved ring buoy with attached 38 foot throw rope. Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gate with openings > 1/2" within 18" of the release mechanism. .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism. - Large gap corrected, gap > 1/2" between gate and post will need to be corrected prior to 2021 permit being issued. Fence with footholds. .2528(a) Maintain fence with no footholds less than 45" high.
#22 · Premises: emergency telephone provided −6
Emergency phone number posted does not match what 911 has. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Corrected.

View this inspection on the county portal ›

Apr 23, 2019 12 demerits · 3 violations
Inspector comments: CPO Dexter Feaster was present during the inspection. Night swimming is NOT permitted.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris.- Observed debris on the bottom of the pool floor. CDI- CPO cleaned bottom of pool floor.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.- Obsrved rocks in skimmers. CDI- CPO removed rocks.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching.- Observed gate near pool pump room to be non self closing. CDI- CPO was able to correct the issue and EHS observed the gate to self close and self latch.

View this inspection on the county portal ›

Apr 13, 2018 6 demerits · 2 violations
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck obstruction. Lounge chair to edge of pool distance less than 6'. Corrected during inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed water on pump room floor. Advised to keep pump room dry.

View this inspection on the county portal ›

Apr 21, 2017 14 demerits · 3 violations
Inspector comments: 29) Currently no mirror installed in the men's restroom. Ensure that if a mirror is installed it is shatterproof and documentation has been submitted to Environmental Health. Permit will be issued at Meckpools.charmeck.org in 1-3 business days. Print a copy to post in the pool area.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Motor for pump not grounded to the pool. Ensure motor is properly grounded. Corrected by operator.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Fence as short as 46.5". Ensure fence is at least 48" high.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
Deck lighting with glass fixtures. Replace glass with plastic or install saftety backing on the glass. Ensure that glass bulbs are replaced with safety bulbs or enclosed such that glass will not get on the pool deck if they break.

View this inspection on the county portal ›

Apr 13, 2016 4 demerits · 1 violation
Inspector comments: Permit not approved until availbe onlinePre-permit inspection passed.PDSC form verified.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck furniture within 6 feet, corrected during inspection. Maintain 6 feet of clearance around pool.

View this inspection on the county portal ›

Apr 15, 2015 2 demerits · 1 violation
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed light and ventilation system tied in together. Provide continuous forced ventilation.

View this inspection on the county portal ›

May 21, 2014 6 demerits · 2 violations
Inspector comments: 5 - General Comment: Record chlorine, pH, main drain check daily. Alkalinity/acid weekly. Post permit visible on pool deck.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
Lights not operational. Replace/repair.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed light/ventilation tied together. Provide continuous forced ventilation.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “BARKLEY PROPERTY OWNERS ASSOC” or State ID 2060500836). Inspection type (routine vs. follow-up) is not published in the county's data.