8demerits

HOLIDAY INN

2707 LITTLE ROCK RD, Charlotte, NC 28214
Seasonal Swimming Pool · NC permit/State ID 2060500838
Latest result8 demerits
Last inspectedMay 27, 2026
Inspections on record13
On record sinceApr 25, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01428 Apr 25, 2014: 8Jun 18, 2015: 28Jun 7, 2016: 12May 30, 2017: 14Jun 27, 2018: 14Apr 25, 2019: 2Jul 28, 2020: 8May 13, 2021: 4Jun 9, 2022: 10May 2, 2023: 10May 15, 2024: 6May 16, 2025: 14May 27, 2026: 8
Apr 25, 2014Lower is betterMay 27, 2026

Inspections & violations

May 27, 2026 8 demerits · 2 violations
Inspector comments: Permit issued No permit restrictions No night swimming 9am-dusk
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Ladder on left side of pool was not secure. CDI- CPO secured ladder.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed both ring buoy ropes at 56ft. CDI - CPO was able to reduce length to 36ft.

View this inspection on the county portal ›

May 16, 2025 14 demerits · 5 violations
Inspector comments: Inspection was conducted with Tony Morris and Raj Desai, CPO. Pool hours will be from 9 am til dusk. PDSC information verified. No permit restrictions. No permitted for nightswimming. Permit issued.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris in skimmers at time of inspection. CDI- CPO cleaned skimmer baskets.
#10 · Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints −2
.2523(e) Safety rope shall be marked with colored floats, 5 ft. apart or less. Safety ropes were not in place separating shallow end from deep end at time of inspection. CDI- CPO put floats in correct position.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Ladder on left side of pool was not secure. CDI- CPO secured ladder in correct place.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed pool chair that was closer than 6 ft to pool edge. CDI- CPO removed pool chair. .2537(2) Decks shall be kept in good repair. Observed some cracks and loose time on pool deck around pool wall.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. There is not 3’ of clearance for walking space in pump room.

View this inspection on the county portal ›

May 15, 2024 6 demerits · 2 violations
Inspector comments: Ensure stingl(vacuum alter system) is tested regularly Emergency phone worked but operator said it was very difficult to hear. Suggest replacing emergency phone
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One skimmer missing weir board. Small amount of debris in skimmer
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Ladder in deep in was loose. Ensure ladders are installed and fitted correctly

View this inspection on the county portal ›

May 2, 2023 10 demerits · 2 violations
Inspector comments: Inspection conducted with Rondell (Ron) Pauling, CPO present. PDSC information verified. No permit restrictions. All non-compliant items corrected during inspection by CPO. Night swimming not permitted. Permit issued.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed 1 of 4 missing weirs. -4-
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed both throw ropes length greater than 36 ft. CDI - both ropes were shortened to 36 ft during inspection. -6-

View this inspection on the county portal ›

Jun 9, 2022 10 demerits · 2 violations
Inspector comments: Flow rate not obtained or recorded due to no permit restrictions. Pool operating hours are from dawn to dusk. Night swimming visit is not required. Night swimming is prohibited at this time.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Repeat Violation: .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris such as leaves and wood pieces in skimmers. CDI: Skimmer baskets were cleaned during inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed both throw ropes length greater than 36ft. CDI: both ropes were shortened to 36ft during inspection.

View this inspection on the county portal ›

May 13, 2021 4 demerits · 1 violation
Inspector comments: No night swimming 80 GPM *Issuance of permit by this Department does not negate meeting requirements of Executive Order 195 or subsequent Orders in effect unless such Orders are rescinded or superseded by another appilcable Order.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris such as leaves wood pieces in skimmers. Remove items fro skimmers.

View this inspection on the county portal ›

Jul 28, 2020 8 demerits · 2 violations
Inspector comments: 75 GPM No night swimming. 15. Two swimming bouys have rope that is 34 Ft. Rope needs to be at least 36 ft according to the rules. CDI- PIC provided rope that were at least 36 Ft. ** According to state and local government, swimming pools are allowed to be open at 50% capacity until told otherwise.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed debris on the pool floor during permit. CDI- PIC Cleaned pool with turtle.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris in skimmers during inspection. CDI- PIC cleaned skimmer baskets.

View this inspection on the county portal ›

Apr 25, 2019 2 demerits · 1 violation
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.

View this inspection on the county portal ›

Jun 27, 2018 14 demerits · 3 violations
Inspector comments: Conducted pre-permit inspection. Observed most issues corrected. 24) 911 has owner of hotel instead of hotel name. Recommend having the phone company change the name tied to the emergency phone line to the hotel name. 24) New flow meter installed on unfilter water line. Flow meter not capable of reading at least 1.5x the pool flow. Existing flow meter right beside an elbow. Recommend installing a flow meter on the filtered pool return line per manufacturer's instructions and capable of reading at least 1.5x the actual flow. Pump motor now bonded to ladder nearest the hotel. Please ensure that other ladder is also properly bonded and that appropriate Code Enforcement electrical permits are pulled. Permit issued with the following conditions. No Night Swimming Single Main Drain Pool. Maintain connected to working SVRS.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Operator checking Calcium Hardness, not testing Cyanuric Acid. Check Cyanuric Acid at least weekly. Operator tested CYA at 55ppm. Left copy of state pool log sheet for operator to use.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Equalizer line cover unseated from backing plate. Install A112 approved covers per manufacturer's instructions. Corrected by operator.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Inlets by ladder and at breakpoint nearest the hotel are not functioning. Recommend checking that the lines are not blocked.

View this inspection on the county portal ›

May 30, 2017 14 demerits · 5 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Thoroughly clean skimmers and skimmer baskets.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Tighten loose rung on top of pool ladder.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Repair damaged section of pool fencing. Observed bent/damaged railing on (1) section of fencing between the two hotels.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Provide cross ventilation in pump/chemical room or continous mechanical ventilation in pump/chemical room.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Provide sign stating "shower before swimming" at pool on deck area or near entrance gate. Intent to suspend permit due to bent/damaged railing on pool fence. Repair damaged section of pool fencing within (30) days!

View this inspection on the county portal ›

Jun 7, 2016 12 demerits · 4 violations
Inspector comments: Single Main Drain. StingL operating
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
ensure that skimmer baskets are free of excess debris. Check frequently.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
ensure that ladders/handrails are tight and secure. Check frequently. Replace compression cups on ladder if needed by 2017 season.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Check flow meter and ensure its functioning properly.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
All non-water tight chemicals should be stored off the floor or stored on pallets.

View this inspection on the county portal ›

Jun 18, 2015 28 demerits · 8 violations
Inspector comments: Single Main drain pool. SVRS in place.Permit not posted. Print permit at Meckpools.charmeck.org and place copy of permit in pool area.Fill line uncapped. Provide cap for fill line when not in use.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Two weirs not installed. Corrected by operator.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Both ladders loose. Maintain in good condition.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
One inlet fitting missing. Multiple returns are dead, with no flow. Maintain all return lines functional and in good condition.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope on ring buoys 39 feet. Corrected to 36 feet.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Deck chairs too close to edge of pool. Maintain at least 6 feet clear walkway around the pool. Corrected by operator.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. Repair or replace.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Dry chemicals stored on the ground. Store in buckets or off of the ground.Provide either cross or forced air ventilation.
#27 · Equipment room: filter backwash discharged through an air gap −2
Provide air gap for backwash line. Line extends down into backwash pit.

View this inspection on the county portal ›

Apr 25, 2014 8 demerits · 2 violations
Inspector comments: #8 Observed 3 (of 4) skimmers deteriorated @ inside tops. Incorrectly noted as 1 on 4/21/14 visit.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed chipped pool walls around lights & chipped pool floor. **correct. (Make sure that all debris that has accumulated on pool wall from nearby stucco installation is removed prior to pool opening.)
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed some lounge chairs ~5' from pool edge. **Maintain 6' of clear walking space.

View this inspection on the county portal ›