8demerits
MCGINNIS VILLAGE
12710 MCGINNIS WOODS DR, Huntersville, NC 28078
Seasonal Swimming Pool · NC permit/State ID 2060500847
Latest result8 demerits
Last inspectedApr 16, 2026
Inspections on record15
On record sinceJun 9, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jun 9, 2014Lower is betterApr 16, 2026
Inspections & violations
Apr 16, 2026 8 demerits · 3 violations
Inspector comments: No Night Swimming.
Pump must be set at 3450 RPM to meet turnover.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed the decking at 1/2” offset where the concrete was cut and filled to install ladder brackets. Not yet a trip hazard but needs to be repaired.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Observed no cross ventilation in chemical storage room.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
.2518(d) Piping and valves shall be labeled with color codes or labels. Observed some piping with missing and faded labels. Relabel as needed.
May 9, 2025 6 demerits · 2 violations
Inspector comments: PERMIT RESTRICTIONS: NO NIGHT SWIMMING. PUMP MSUT BE SET TO 3450 RPMS FOR TURNOVER. PUMP AT 3450 RPS DURING INSPECTION.
PERMIT ISSUED.
EXTRA CARTRIDGE FILTERS ON SITE.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
Observed the decking at 1/2” offset where the concrete was cut and filled to install ladder brackets. Not a trip hazard but needs to be repaired.
.2537(2) Decks shall be kept in good repair.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.
Observed boxes of chemicals stored on chemical room floor.
May 8, 2025 12 demerits · 2 violations
Inspector comments: PERMIT RESTRICTION - SPEED REQUIRED AT 3450 RPM DUE TO TURNOVER. OBSERVED AT 3450 RPM AND AUTOMATED
CHORINE FEEDER.
NO NIGHT SWIMMING.
Permit denied. A $100 return inspection/visit fee is required to be paid to Public Health before a return visit will be scheduled. To pay the required fee,
contact Public Health at 980-314-1620 and request to pay the $100 fee for your swimming pool. Please assure that you have all
information required before contacting Public Health.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm.
Observed chlorine testing at 0ppm. Permit denied.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8.
Observed pH testing at 8.2
Permit denied.
May 7, 2025 26 demerits · 5 violations
Inspector comments: PERMIT RESTRICTION - SPEED REQUIRED AT 3450 RPM DUE TO TURNOVER. OBSERVED AT 3450 RPM AND AUTOMATED CHORINE FEEDER.
NO NIGHT SWIMMING.
A $100 return inspection/visit fee is required to be paid to Public Health before a return visit will be scheduled. To pay the required fee, contact Public Health at 980-314-1620 and request to pay the $100 fee for your swimming pool. Please assure that you have all information required before contacting Public Health.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm.
Observed chlorine testing at 0ppm. Permit denied.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8.
Observed pH level testing over 8.0 Permit denied.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7.
Observed equalizer line not plugged in 1 skimmer. CDI.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions.
Observed missing end cap on ladder.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
Observed throw rope was tethered together. CDI- throw rope replaced by CPO (50’).
Apr 24, 2024 10 demerits · 2 violations
Inspector comments: Pool is not permitted for night swimming. Permit issued. Verified pump speed locked at 3450 due to turnover.
#3 · Water quality: pool water pH −6
Observed pH in pool measuring 6.9. CDI: CPO raised pH to 7.2
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed debris accumulating in corners of pool floor. CDI: CPO began cleaning during inspection.
Apr 13, 2023 0 demerits · 0 violations
Inspector comments: NO VIOLATIONS OBSERVED DURING TIME OF INSPECTION.
No violations were recorded for this inspection.
Apr 18, 2022 6 demerits · 1 violation
#3 · Water quality: pool water pH −6
OBSERVED POOL PH MEASURING TOO LOW 6.8; CDI PH CORRECTED DURING INSPECTION TO 7.2 (FEEDER WAS SET TOO LOW PRIOR TO INSPECTION).
Apr 16, 2021 8 demerits · 3 violations
Inspector comments: Dexter on site. No night swimming.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Provide no openings in fence and/or gate greater than 4"x4".
observed openings in pool fence > 4".
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors.
Restroom mirrors are not shatterproof
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
.2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer.
no backlow device installed.
May 29, 2020 4 demerits · 1 violation
Inspector comments: No night swimming.
permit issued.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris in skimmers. CDI- PIC cleaned out skimmer baskets.
Apr 11, 2019 14 demerits · 3 violations
Inspector comments: 7. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
Skimmers had leave, pollen, other debris and rocks inside of it. Clean out skimmers.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8.
pH of the pool was 8.1 . Pool operator fixed pH and it went down to 7.7 during inspection.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone.
Emergency phone dailing instructions say to dail 911, phone does not have numbers and automatically dials 911. Pool operator provided signange during inspection to just pick up phone.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water.
Pump room had water on the floor. Pool operator will clean it up.
Apr 13, 2018 2 demerits · 1 violation
Inspector comments: John Rhodes was present during the inspection.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Observed the piping was not labeled in the pump room. Piping was labeled during the inspection.
.2518(d) Piping and valves shall be labeled with color codes or labels.
May 9, 2017 8 demerits · 4 violations
Inspector comments: Pool passed pre-inspection
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
1 ladder > 6" from pool wall
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Continuous forced or natural cross ventilation required in pump room
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Mirrors to be of shatterproof construction
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Backflow preventer required on hose bib
May 24, 2016 8 demerits · 2 violations
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Observed equipment on-site not matching approved PDSC form. Resubmit PDSC form. Immediate Suspension issued.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed men's restroom door not closing.
Jun 9, 2015 8 demerits · 3 violations
Inspector comments: Chlorine raised to 2.0ppm. Permit re-instated.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed no adjustments recorded in book when chlorine or pH when out of compliance.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed loose handrail. Repair.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed pump room floor wet and no forced or cross ventilation present. Keep pump room floor dry and provide ventilation.
Jun 9, 2014 16 demerits · 5 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Clean pool floors.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Repair stuck weir in skimmer basket.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Tightly secure handrail to pool deck at step area.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Repair flow meter. Flow meter is stuck. Replace blown light bulb in chemical room or repair light fixture.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Repair toilet in men bathroom. Mirrors are not shatterproof.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “MCGINNIS VILLAGE” or State ID 2060500847). Inspection type (routine vs. follow-up) is not published in the county's data.