8demerits
CLAYBROOKE SWIM CLUB
10240 CLAYBROOKE DR, Charlotte, NC 28262
Seasonal Swimming Pool · NC permit/State ID 2060500852
Latest result8 demerits
Last inspectedApr 16, 2026
Inspections on record13
On record sinceMay 9, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
May 9, 2014Lower is betterApr 16, 2026
Inspections & violations
Apr 16, 2026 8 demerits · 2 violations
Inspector comments: Pump must be set at max speed 3450 -or- flow meter must remain operable with flow at 104gpm to 141gpm to meet turnover and flow restriction of the filter flow.
Construction date: 7/1/1999
Rope Length: 30’
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521(b) Ladders shall have slip-resistant tread. One ladder missing tread on top step.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Rope longer than required 30’. PIC cut and knotted rope for compliance during inspection.
Apr 11, 2025 8 demerits · 2 violations
Inspector comments: In field plan review items noted as present, pictures sent via email to C. Sells
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Slight debris on pool floor, cleaning during inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Deck chairs observed within 6 feet, moved during inspection.
Apr 25, 2024 4 demerits · 1 violation
Inspector comments: NOTE: 3 HP housing on a 2 HP challenger pump verified.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmer in need of cleaning.
Apr 5, 2023 16 demerits · 5 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed debris on pool floor.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed one missing weir.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter stuck . PIC adjusted flow meter and flow meter now operational.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed discharge pipe below flood rim of drain.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. Observed mirrors in restrooms not shatterproof.
May 26, 2022 10 demerits · 3 violations
Inspector comments: 24. Pump has been approved - 3HP model number on pump housing but the pump is a 2HP - impeller verification paper work submitted by Brian Yarmon
#3 · Water quality: pool water pH −6
pH corrected to 7.8 during inspection
#27 · Equipment room: filter backwash discharged through an air gap −2
2" air gap required on backwash line
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
restrooms need to be cleaned; mirrors to be of shatterproof construction
May 7, 2021 8 demerits · 3 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed debris in pool.
**.2537(14) Keep pool surface and pool floor free of debris.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ladder missing slip-resistant tread.
**.2521(b) Ladders shall have slip-resistant tread.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed no air gap in the pump room.
**.2513(b) Filter backwash shall be discharged through an air gap.
Apr 28, 2020 16 demerits · 5 violations
Inspector comments: 13 GC - recommend repainting contrasting band on steps during off season
25. GC - keep light switch on so fan runs continuously or put on light and fan on separate switches
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
PDSC form revised to reflect the pump - approved during inspection
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Replace missing tread on ladder
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Replace broken deck drain
#27 · Equipment room: filter backwash discharged through an air gap −2
2" air gap required on backwash line
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Mirrors to be of shatterproof construction; Replace light switch panel in women's restroom to be a 1-switch panel (hole in panel allows access to exposed wires
Apr 24, 2019 4 demerits · 1 violation
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Significant debris on pool floor. Cleaning began while on site.
Apr 12, 2018 22 demerits · 5 violations
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm.
Observed chlorine at .8 ppm. CDI chlorine brought up to 2ppm.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris.
Observed pool floor with debris but still able to see inlets and main drains.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
Observed skimmers with debris.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair.
Observed crack on deck at side corner of pool.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational.
Observed flow meter that was not operating.
Apr 17, 2017 6 demerits · 2 violations
Inspector comments: Observed 2 returns with incomplete eyeball fittings. As per conversation with Tim Dutcher of MCHD, these will not be permit action items. Provide the parts and properly assemble the fittings.
POOL PASSES PRE-INSPECTION. PERMIT SHOULD BE ISSUED IN 1-3 BUSINESS DAYS. POST PERMIT IN PUBLIC VIEW AT POOL DECK.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed plaster chunks on the pool floor. These were removed by the operator. -C.D.I.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed backwash line not to have an air gap. This is not a permit action item.
May 4, 2016 20 demerits · 5 violations
Inspector comments: Permit will be issued in 1-3 business days. Go online to Meckpools.charmeck.org to print permit and post a copy in the pool area.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Main drain and equalizer line covers do not match what was on approved PDSC form. Correct PDSC form submitted and approved by CPO.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope 32 feet. Provide throw rope that is 30 feet. Corrected by CPO.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. Repair or replace. Corrected by CPO.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
General storage beside pool equipment. Maintain at least 3 feet clear walkway around equipment.
#27 · Equipment room: filter backwash discharged through an air gap −2
Provide air gap for backwash.
Apr 30, 2015 12 demerits · 4 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed debris present in areas of pool. Clean pool of debris.General Comment: Observed 2'" color band visible at stairs, but slightly fading. Color band in need of repaintingObserved some "NO DIVING" spray painted signs on deck surface visible, but as well slightly fading. Repaint no diving signs.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris collecting in baskets. Corrected during inspection - baskets were emptied.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed air gap not present at backwash. Provide air gap at backwash.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed leak at piping underneath girls hand sink. Corrected during inspection - Piping was tighened.
May 9, 2014 10 demerits · 2 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Repair the broken tiles on the pool wall.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Rope measured 66ft. Rope was cut to required 30 feet onsite.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “CLAYBROOKE SWIM CLUB” or State ID 2060500852). Inspection type (routine vs. follow-up) is not published in the county's data.