0demerits
TRELLIS-WEST CHARLOTTE
2770 YORKMONT RD, Charlotte, NC 28208
Seasonal Swimming Pool · NC permit/State ID 2060500872
Latest result0 demerits
Last inspectedMay 19, 2026
Inspections on record13
On record sinceMay 28, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
May 28, 2014Lower is betterMay 19, 2026
Inspections & violations
May 19, 2026 0 demerits · 0 violations
Inspector comments: Permit Issued
No violations observed
No night swimming
Permit restriction verified - Flow meter shall remain operable. Flow shall not exceed 63 gpm due to drain cover flow restriction. Suction Hazard. Note: CC8xxx drain cover. Old equalizer drain cover used in middle of the new drain cover.
No violations were recorded for this inspection.
Jul 29, 2025 14 demerits · 4 violations
Inspector comments: Property under renovation at time of inspection. If restrooms are remodeled they must meet full compliance of pool code. Submit in-field plan review to Health Dept (include slip resistant flooring specs, floor drains, hose bib with anti siphon device and shatterproof mirrors, no glass)
No Night Swimming. Pool not heated
Inspection with Curtis Baker
Issued permit sticker.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
One loose ladder. Keep tight and in good repair.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Buoys on deck not US Coast Guard approved and rope too long at time of inspection.
.2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy.
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Operator attached 27 ft rope to approved buoy and replaced. Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gate not latching at front. Back fencing area, replaced with grills, 37” in height.
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
.2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010).
.2537(b) All gates and doors shall be self-closing, self-latching. Operator adjusted gate to self-close, self-latch.
Operator added plywood to grill area to increase height of barrier to 48” and eliminate horizontals. If further changes are made, ensure code is met. Corrected.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Restrooms out of order.
.2526(m) Keep restrooms and fixtures clean and in good repair.
May 23, 2024 16 demerits · 3 violations
Inspector comments: POOL PERMIT DENIED DUE TO EMERGENCY PHONE NOT WORKING, GATE NOT SELF CLOSING, AND LOW PH
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8.
PH RECORDED AT 7.0
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching.
Back gate did not self close. Stayed open at a 60 degree angle.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable.
Cannot call emergency phone.
Aug 9, 2023 6 demerits · 1 violation
Inspector comments: Inspection conducted with operator Jim Switala. Permit denial issued due to emergency phone not receiving call back to monitored system or to pool deck. Once emergency phone is corrected, call the main office at 980-314-1620 to request a re-inspection. A $100 re-visit fee may apply.
The following items verified during inspeciton:
Hayward Super Pump VS, W3SP2603VSP, 1.65 hp pump
Blue White flow meter installed on 2” pipe. Shall have at least 20” on inlet and 8” on outlet.
Main drain and skimmer line 2.5” pipe; Return line 2” pipe
Aquastar VGB-2017 CC8xxx drain covers. They’ve used an old drain cover in the middle of it so it may not look like what you are used to seeing. See attached pdsc with picture.
(2) Aquastar 6HPHAxxx EQ line covers VGBA2017
Pentair TR100C filter
(5) returns
(2) skimmers
Flow verified at 55 gpm on Blue White Flow meter.
Night swimming not permitted. Ensure posted hours indicate pool closes for swimming at dusk.
Note: at required pump setting, filter operating at low psi. Operator must monitor water clarity to ensure filtration occurring. If issues with water clarity arise, modifications to filter may be required.
Note: Current EcoLab in line disinfection system may not be effective. Manual disinfection of pool is not permitted. If in current in line system is not meeting demands of pool, additional in line chlorination may be required.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Emergency phone system phone number when called back goes to main number with option of front desk, however, due to concept change from hotel to apartment, this desk is no longer staffed / monitored for return calls. Emergency phone must either accept return calls directly onto pool deck or must be directed through 24 hour monitored system.
*permit denial item
May 12, 2022 0 demerits · 0 violations
Inspector comments: Inspection conducted with Jim Swatala.
No violations were recorded for this inspection.
Jun 7, 2021 4 demerits · 1 violation
Inspector comments: 11. Tighten handrail of ladder on right side of pool.
120 GPM
No nightswimming permitted.
Issuance of permit by this Department does not negate meeting requirements of Executive Order 195 or subsequent Orders in effect unless such Orders are rescinded or superseded by another appilcable Order.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Chipped paint observed on pool walls and floor. Repairs shall be made during the offseason.
Jul 8, 2020 0 demerits · 0 violations
Inspector comments: no night swimming
No violations were recorded for this inspection.
May 16, 2019 8 demerits · 2 violations
Inspector comments: 11. Ladder was loose at time of inspection. Pool operator secured ladder to deck.
**Night swimming has been verified. ALL light in pool and surround pool deck are in working order.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Daily checklist does not include drain cover/grate inspections. CDI- Column was made to make checks to drain covers daily.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Four areas in fence were greater than 4"X4". CDI- Repairs were made to the gate in a permanant manner to enclose areas greater than 4"x4".
May 16, 2018 2 demerits · 1 violation
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed loose handrail. CDI-tightened
Jun 19, 2017 12 demerits · 3 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530, .2537 Throw ring available with correct rope length; Observed throw ring with rope that was too long; CDI corrected to proper length (27ft). |
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522, .2537 Decks unobstructed; Observed deck chairs stored within 6ft of pool edge.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533, .2534, .2537 Pump room dry; Observed small leak from pump in pump in need of repair.
Forced/natural ventilation; Observed vent turned off.
May 6, 2016 4 demerits · 1 violation
Inspector comments: 5. INCLUDE DRAIN AND EQUALIZER COVER CHECKS ON DAILY RECORDS
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
POOL FLOOR DIRTY -- CLEAN PRIOR TO OPENING
May 14, 2015 8 demerits · 3 violations
Inspector comments: General comments:Operator was advised to add area for documentation for checking main drains daily.13. One section of the contrasting color band on the bottom step has been covered with resurfacing material. Color bands on remainder of the stairs are visible. Operator Jayme Almeida was advised that return visit will be completed by June 13, 2015 to check for repair of contrasting color bands.17. Two deck chairs obstructing the six feet of deck clearance. Operator corrected. Three small holes in the pool deck at the adjoining edges of the pool deck and pool edge. Repair holes.Please allow 2-3 business days to access pool permit at meckpool.charmeck.org. Permit must remain posted at pool at all times.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some debris in the bottom of the pool. CPO Jayme Almeida advised that he is continuing to clean the bottom of the pool due to some issues with debris from the pool deck repair.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Handrail at the far end of the pool away from the main lobby entrance is loose. Repair/ tighten handrail.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Directional lines on pool pump faded or missing on some lines. Directional lines are needed.
May 28, 2014 18 demerits · 5 violations
Inspector comments: Monitor pH closely! Check cyanuric acid and total alkalinity weekly! Pool just opened Saturday and no record or cyanuric acid or total alkalintiy test record in record book. Mr. Jayme Almeida present at time of inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Replace missing weir in skimmer baskets! Repair within 30 days!
#13 · Pool maintenance: contrasting band on steps and benches −4
Replace missing contrasting band tile on edge of steps entering into swimming pool or paint a two inch contrasting color band on step entering into swimming pool. Repair by next swimming pool season!
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed skimmer located on pool deck protruding on pool deck . Repair pool deck around skimmer to prevent a trip hazard! Repair within 30 days!
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Repair stuck flow meter!
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Label piping to show the flow of water through circulation of pumps and piping. Draw arrows on piping!
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “TRELLIS-WEST CHARLOTTE” or State ID 2060500872). Inspection type (routine vs. follow-up) is not published in the county's data.