6demerits
BOARDWALK AT DEERPARK
509 SOUTHEAST DR, Davidson, NC 28036
Seasonal Swimming Pool · NC permit/State ID 2060500897
Latest result6 demerits
Last inspectedApr 21, 2026
Inspections on record14
On record sinceApr 17, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Apr 17, 2014Lower is betterApr 21, 2026
Inspections & violations
Apr 21, 2026 6 demerits · 2 violations
Inspector comments: NO NIGHT SWIMMING.
PERMIT RESTRICTION:
FLOW METER MUST REMAIN OPERABLE. FLOW SHALL NOT EXCEED 119 GPM DUE TO FLOW RESTRICTION OF THE DRAIN COVERS.
SUCTION HAZARD.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris.
Observed debris on pool floor. CDI- CPO is in process of cleaning the pool.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
.2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. Observed missing back flow preventer.
Apr 10, 2025 0 demerits · 0 violations
Inspector comments: NOTE: Auto-chlorinator not in use.
no violations noted
No violations were recorded for this inspection.
May 10, 2024 4 demerits · 1 violation
Inspector comments: NOTE:
- CPO: Kara Gilchrist present during inspection.
PERMIT RESTRICTION: Flow meter must remain operable. Flow shall not exceed 119 GPM due to flow restriction of drain covers.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(b) Provide at least 5 ft of clear walking space around the pool at all times.- Observed space between pool deck and furniture is at 3ft. Furniture rearranged to provide required space at the time of inspection.
May 11, 2023 2 demerits · 1 violation
Inspector comments: NO NIGHT SWIMMING
Restroom was accessible today with working toilet and hand sink.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
.2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. No backlflow preventer.
Apr 21, 2023 20 demerits · 5 violations
Inspector comments: Permit denied today. This pool must remain closed until a re-inspection can be completed and permit issued.
Call 980-314-1620 to request a re-inspection and pay return visit fee.
Permit denial sheet documented on paper form.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm.
Observed chlorine testing at 0ppm. Permit denied
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
Observed floating debris in skimmers. CDI
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable.
.2530(f) Pool telephone shall be capable of directly dialing 911 or another emergency notification system.
Observed pool emergency phone was not working today. Could not call 911. Permit denied
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(a) Provide at least one sink and toilet for residents and guests if furthest unit is more than 300 feet from the pool at hotels, motels, condominiums and apartments. Observed pool restrooms were under renovations and inaccessible. Contact Katie Rudisill or Tim Dutcher to discuss further action. Permit denied.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
.2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer.
No backflow preventer on hose bib.
Apr 22, 2022 4 demerits · 2 violations
Inspector comments: EHS confirmed PDSC information. Operator Kara Gilchrist on site during inspection. Permit issued.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap at backwash outlet.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. Observed no shatterproof mirrors in bathrooms.
Apr 15, 2021 8 demerits · 3 violations
Inspector comments: Kara Gilchrist on site. No night swimming.
karagilchrist@aol.com
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool.
observed depth markings more than 25ft apart in deep end of the pool. CDI added 4.5 ft depth marker.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap.
no air gap at backwash outlet
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors.
mirrors in restroom are not shatterproof.
Apr 27, 2020 8 demerits · 3 violations
Inspector comments: All 4 and 6 point items in compliance by end of inspection.
Issuance of a permit by this department does not negate closure required by Executive Order No. 120 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k)(3) Maintain skimmers in good repair. Observed deck skimmer at 3.5 ft with crack in collar. CDI: CPO filled crack with epoxy putty “fix-it stick” to create watertight collar. If repair cannot be maintained, skimmer will need to be replaced.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Observed cracked collar on deck ladder at 4ft end of pool.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap at back wash pit.
Apr 15, 2019 16 demerits · 4 violations
Inspector comments: CPO Kara Gilchrist was present during the inspection.
Night Swimming is not permitted.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. - Observed debris on the bottom of the pool floor. EHS was still able to see the pool floor and verify main drains. CPO will clean pool floor before opening.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Observed debris in skimmer baskets. CDI- CPO removed debris.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. - Observed ring buoy rope to be 50 ft. CDI- CPO provided rope at 36 ft.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. - Observed pump room floor with standing water. EHS did not observe any leaking pipes.
Apr 24, 2018 18 demerits · 6 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris in skimmer. Cleaned out skimmers during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed first horizontal to second horizontal is less than 45 inches. Construction date is 2000.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed lounge chairs within 6 feet from pool edge. Relocated lounge chairs.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed water in the pump room.
#27 · Equipment room: filter backwash discharged through an air gap −2
Provide air gap for pipe at backwash pit. Observed pipe down in open pit with no true air gap.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Observed hose bibb next to restrooms with no backflow preventor. Advised to provide back flow prevention to hose bibbs.
Apr 11, 2017 8 demerits · 2 violations
Inspector comments: OBserved Chlorine test kit above 10 ppm; test kit did not bleach out. Sanitizer test strip was used and pool read out to be at 50 ppm. Danny (Aquatech) verified that the salt dispenser reads at 2900 and that the back up chlorinator is still on. Danny turned off back up chlorinator; EHS will make visit 4.19.17 to check chlorine ppm and verify that the salt dispenser works properly on its own.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed first horizontal of fence less tan 45".
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck obstruction. Lounge chairs within 6' of pool edge. Corrected during inspection.
Apr 19, 2016 16 demerits · 4 violations
Inspector comments: Unable to determine make and model of pump. Records submitted by Management company indidcate Pentair Challenger CHI-NI-2F 2 HP pump. No data plate stating Pentair observed. Observed Century Centurion pump motor as 2 HP. Pictures of pump sent and approved by K Wilson.
#3 · Water quality: pool water pH −6
Maintain pH between 7.2 and 7.8. Observed pH at 6.9. CDI-pH brought up to 7.2.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Maintain correct length of rope on ring buoy. Observed rope length at 50 feet. Pool is required to have rope at 36FT. CDI-rope cut to 36FT.
#27 · Equipment room: filter backwash discharged through an air gap −2
Provide air gap for pipe at backwash pit. Observed pipe down in open pit with no true air gap.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Provide back flow preventor on hose bibbs. Observed hose bibb next to restrooms with no backflow preventor. CDI-backflow preventor provided.
Apr 17, 2015 8 demerits · 2 violations
Inspector comments: NOTE: Permit will be posted online within 3 days at meckpools.charmeck.org.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed "FT" markers and "NO DIVING" signs faded and not clearly visible. CDI - colored in with black permanent marker during inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Maintain required rope length at 36FT. Observed rope length < 36FT. CDI - rope stretched to 36FT during inspection.
Apr 17, 2014 10 demerits · 2 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Rope length initially not long enough - Corrected during inspection (36')
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Keep patio furniture at least 6' from pool edge.