‹ Back to search

4demerits

GLENLEA PARK

5150 GLENLEA PARK DRIVE, Charlotte, NC 28216
Seasonal Swimming Pool · NC permit/State ID 2060500902
Latest result4 demerits
Last inspectedJun 22, 2026
Inspections on record12
On record sinceAug 22, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

02142 Aug 22, 2014: 42Jun 1, 2015: 20Jul 15, 2016: 32Jun 14, 2017: 10May 25, 2018: 2Apr 18, 2019: 0May 22, 2020: 4May 19, 2021: 8Apr 21, 2022: 10Jun 8, 2023: 4Apr 30, 2024: 8Jun 22, 2026: 4
Aug 22, 2014Lower is betterJun 22, 2026

Inspections & violations

Jun 22, 2026 4 demerits · 1 violation
Inspector comments: All of the following has been fulfilled: 1.) Permit Restriction - Flow meter must remain operable. Flow required at 210 to 227 gpm to meet turnover and flow restriction of return line. Flow greater than 275 gpm exceeds main drain cover. Suction Hazard. 2.) New Pumps (2) Pentair Intelliflo3 VSF 011076, 3 hp pumps 3.) FlowVis flow meter reading the above flow range. 4.) Main drain 3” line; Skimmer 4” line; Return 3” (all stubbed up through the pool slab) 5.) (2) Aquastar 914xxx 2017 drain covers. 6.) (6) Aquastar 6HPHAxxx 2017 equalizer line covers 7.) (2) Pentair TR140C filters 8.) (6) returns, either on the floor or wall. NIGHT SWIMMING NOT PERMITTED***
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed 2 small sections of the fence with 5-7 inches of space underneath. -Corrected During Inspection- Spaces were filled with dirt/gravel.

View this inspection on the county portal ›

Apr 30, 2024 8 demerits · 3 violations
Inspector comments: No night swimming. Inspection completed with CPO Mikey Cook Permit restrictions: Both Pumps tied together - pull through same drains/eq lines (4) 6HPxxx (2) 4HPxxx
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed 1 weir on 3ft closest to clubhouse missing. CDI: weir replaced during inspection
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(i) Water in restrooms shall not exceed 110 F. Observed water in restrooms > 110F. .2526(k) Provide shatterproof mirrors. Mirrors in restrooms are not shatterprooof.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
.2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. Deck hose bib used periodically to fill pool observed without back flow preventer.

View this inspection on the county portal ›

Jun 8, 2023 4 demerits · 1 violation
Inspector comments: Inspection conducted with CPO Danielle Parker. Note* Sta-Rite P4E6F-188L pump with 2 HP motor and Sta-Rite MPRA6F-148L pump with 1 HP motor. Labels still on both pumps. Emergency phone was relocated. Difficult to read emergency phone sign from new location. Recommend moving emergency phone sign such that users can easily read the address and dialing instructions. Not able to test doors from clubhouse to the pool deck. Ensure doors are kept closed and locked or are maintained self-closing and self-latching. Permit issued No Night Swimming Paper permit will be available on our website https://health.mecknc.gov/envhealth/pools in 3-5 business days for your records.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Pre-2010 fence with 36" between the horizontals on the fence. .2528(b) Horizontals shall not be located less than 45" in height. Some gaps > 4” under the fence. .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). - Corrected.

View this inspection on the county portal ›

Apr 21, 2022 10 demerits · 3 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521(b) Ladders shall have slip-resistant tread. Observed 2 ladders with 4 non slip treads missing. PO will verify with EHS that they have been fixed before opening. .2521 Install ladders per manufacturer instructions. Ladders/ handrails were missing the tightening mechanism (in all of them) PO was able to tighten and stabilize them by the end of inspection
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010). Observed only 37" between the horizontals on the fence. Pool is pre 2010.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Observed a large crack-1ft-right next to the edge of the pool. Crack was making the pool deck unstable to step on and EHS could move the concrete underneath. PO was able to putty it while on site but they are going to come back out and put a better adhesive on it later. EHS will follow up with this.

View this inspection on the county portal ›

May 19, 2021 8 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmer missing weir board. Skimmer furthest form pump had debris settling in bottom. Corrected during inspection
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter suck. Corrected during inspection

View this inspection on the county portal ›

May 22, 2020 4 demerits · 1 violation
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. - Observed flow meter not operating. Fixed during inpsection. Adam was present.

View this inspection on the county portal ›

Apr 18, 2019 0 demerits · 0 violations
Inspector comments: No violations.

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 25, 2018 2 demerits · 1 violation
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Repair ventilation in chemical/pump room. Mechanical ventilation should be continous operating and not tied to light switch or provide cross ventilation in chemical/pump room.

View this inspection on the county portal ›

Jun 14, 2017 10 demerits · 3 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Clean corner/edge of pool floor and wall.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Repair stuck flow meter.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Repair light fixture in chemical/pump room. Repair ventilation in chemical/pump room. Mechanical ventilation should be continous operating and not tied to light switch or provide cross ventilation in chemical/pump room. General Comment: Monitor pool deck where concrete is cracked near pool coping. Replace weathered rope on ring buoy.

View this inspection on the county portal ›

Jul 15, 2016 32 demerits · 8 violations
Inspector comments: Report received by Rod Sandy Immediate suspension issued for #6
#3 · Water quality: pool water pH −6
pH > 7.8
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Main drain covers & equalizer line covers do not match VGB form information
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Baskets need to be free of debris
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Body hook needs to remain on pool deck and accessible for use - hook moved onto deck during inspection
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Pool pumps have not been approved
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Light bulb is burned out. Natural cross or continuous forced ventilation required
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Bathrooms locked and inaccessible for inspection
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Backflow preventer required on hose bib

View this inspection on the county portal ›

Jun 1, 2015 20 demerits · 6 violations
Inspector comments: 15) Throw rope and ring buoy rope fraying. Recommend replacing.
#3 · Water quality: pool water pH −6
pH 8.1. Maintain between 7.2 and 7.8.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
5 of 6 weirs stuck. Skimmers must have functional weirs. Pool was closed for this at the end of last year. Must be corrected before pool can open.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder with broken step. Fix step.Handrail loose. Maintain in good condition.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gap > 4" under portion of fence adjacent to clubhouse. Maintain fence with no gaps > 4".
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemical storage room full of Christmas decorations. Chemicals not currently stored on site. Maintain a chemical storage room for pool chemicals.General storage in chemical storage room. Maintain 3 feet clear walkway around pool equipment.
#27 · Equipment room: filter backwash discharged through an air gap −2
Backrwash not discharged through an air gap. Provide an air gap.

View this inspection on the county portal ›

Aug 22, 2014 42 demerits · 12 violations
Inspector comments: 15 - General Comment: Some dry rot on grab rope of ring buoy. Replace for 2015 season. Submit updated PDSC form for equalizer lines within 1 week. Intent to Suspend issued for #8, #9, #16, #17 and #29
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Algae on pool walls and chipping plaster on pool floor. Keep clean and keep in good repair. Damage to wall tile. Repair.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Weirs stuck on all skimmers. Keep operational. Intent to Suspend issued.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
1 ft wall depth markers not visible. Replace. Intent to Suspend issued.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gate not self-closing. Repair to self-close. Intent to Suspend issued. 35" between horizontals on fence. Maintain at 45".
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Damage to coping. Severe at 4 ft. Repair. Intent to Suspend issued.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
Pool lights not operable. Repair.
#22 · Premises: emergency telephone provided −6
No dialing instructions. Corrected.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. Keep operational.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Pool cover stored in pump room. Provide 3 ft clear walking space. Light and fan tied together. Provide separate.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap. Provide at backwash line at pit.Cut drain pipe flush to floor.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Urinal not operable and one sink not operating in women's. Repair. Intent to Suspend issued. Water at >113 F. Maintain at 110 F or below.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Provide backflow prevention device on all hose bibs.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “GLENLEA PARK” or State ID 2060500902). Inspection type (routine vs. follow-up) is not published in the county's data.