14demerits
PROSPERITY VILLAGE
12400 JESSICA PL, Charlotte, NC 28269
Seasonal Swimming Pool · NC permit/State ID 2060500905
Latest result14 demerits
Last inspectedApr 24, 2026
Inspections on record13
On record sinceMay 9, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
May 9, 2014Lower is betterApr 24, 2026
Inspections & violations
Apr 24, 2026 14 demerits · 3 violations
Inspector comments: Permit restriction: Flow meter must remain operable. Pump flow must be set at least 78 gpm for turnover and cannot exceed 98 gpm for filter limitation. Flow greater than 119 gpm exceeds the main drain flow. Suction Hazard.
No Night Swimming.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed leaves on floor of pool. Clean as needed.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris present in skimmers. Clean as needed.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed pool rope at 60 ft. CDI - Rope cut to 39 ft.
May 13, 2025 2 demerits · 1 violation
Inspector comments: Free Chlorine was <1.0 when first checked. Corrected to 3.0 ppm by end of inspection.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap.
Jun 26, 2024 14 demerits · 4 violations
Inspector comments: This pool is not permitted for night swimming.
Pool is listed to have 8 returns but during inspection only 7 were observed. Pool is able to meet turnover rate calculation.
The following items were field verified:
Pump Hayward SP32950VSP
Piping 2” main drain, skimmer and return (where it comes up and goes into the pump room floor)
Flow meter Between 78 and 98gpm (Observed flow during inspection was 97)
Filter TR100HD
Main Drains Aquastar A10RCFRxxx
Equalizers Aquastar 6HPHAxxx
Skimmers 3
Permit issued.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed one inch separation of coping from tile on pool wall creating a gap. Repair. A follow-up inspection will be conducted to ensure this is repaired.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed buoy rope measuring over 39 ft. Rope is required to be 39 ft based on 1.5 times width of pool. CDI: Pool operator adjusted length for compliance.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(b) Provide sufficient lighting in pump room. Observed light not operating in pump room. Pool operator states that it is a fixture issue and that it will be getting repaired. Repair to ensure sufficient lighting.
.2533(e) Provide continuous forced ventilation or cross ventilation in pump room.observed no cross ventilation in pump room. One grate present on door.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed backwash pipe below rim of drain pit. Correct to provide an air gap.
May 10, 2023 2 demerits · 1 violation
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. Observed chemicals stored on floor in pump room.
May 5, 2022 16 demerits · 5 violations
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Missing equalizer cover, replaced during inspection as per PDSC form-Aquastar 6HP
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Re-caulk top of tile line along pool edge-caulk missing in places
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Natural cross or continuous forced ventilation required in equipment & chemical room; light needed in chemical room
#27 · Equipment room: filter backwash discharged through an air gap −2
2" air gap required on backwash line
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Mirrors to be of shatterproof construction
Apr 9, 2021 2 demerits · 1 violation
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed hot water reach 113F in the restroom.
**.2526(i) Water in restrooms shall not exceed 110 F.
May 22, 2020 0 demerits · 0 violations
Inspector comments: Inspection conducted by Kiana Chrisp 5/22/2020. Permit issued and uploaded to OnBase. T. Dutcher 7/7/2020
No violations were recorded for this inspection.
May 17, 2019 8 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. debris in skimmers. CDI- cleaned while on site.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(a) Provide depth markers on pool walls and pool deck at points of maximum and minimum depths. 5FT marker on deck dteriorated. CDI- stencils used to re-paint marker.
May 11, 2018 12 demerits · 3 violations
#3 · Water quality: pool water pH −6
Observed pH at 7.0. Corrected during inspection to 7.2.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed debris on surface of water and pool floor/walls. Needs to be cleaned.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed dust build up on vent covers in restrooms.
May 9, 2017 8 demerits · 4 violations
Inspector comments: 9. "NO DIVING" message added to deck
17. Cracks in pool deck have been filled in
22. Confirmed address and phone number with 911 operator
24. Flow meter is working
26. Labels have been remarked
#27 · Equipment room: filter backwash discharged through an air gap −2
2" air gap required on back wash line
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Natural cross or continuous forced ventilation required in equipment room
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Mirrors to be of shatterproof construction (urinal has been repaired)
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Backflow preventer required on hose bib
May 10, 2016 10 demerits · 4 violations
Inspector comments: PDSC form verified- PDSC form states pool contains 4 skimmers. Pool contains 4 skimmers, not 3. Informed CPO to re-submit PDSC form.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Observed "No Diving" markers in deep end of pool to be heavily faded and unreadable. CDI- CPO re-spray painted new markers.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed handrail to stairs loose. Repair.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed no air gap present at backwash pipe to height of pit. Provide.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed mirrors in both restrooms to not be shatter resistant. Provide shatter resistant mirrors.
Apr 21, 2015 12 demerits · 4 violations
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Maintain 4" max distance from bottom of fence to grade. Observed loose point of fence with larger than 4" gap at bottom that onlyhad sand covering gap. Secure the fence, place gravel, or other effective way to cover gap.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter not functioning, repaired on site.
#27 · Equipment room: filter backwash discharged through an air gap −2
Maintain air gap. No air gap from backwash pipe to height of pit.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Floor in women's restroom is peeling in several areas and in men's restroom in a few areas, needs repair.GENERAL COMMENT: PERMIT TO BE ISSUED
May 9, 2014 2 demerits · 1 violation
#27 · Equipment room: filter backwash discharged through an air gap −2
Maintain air gap. No air gap from backwash pipe to height of pit.General Comment: Depth marker tile added on pool wall to correct #9 and gravel added to ground to correct gap of fence to ground from item #16, Restrooms cleaned to correct #29. Permit Issued.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “PROSPERITY VILLAGE” or State ID 2060500905). Inspection type (routine vs. follow-up) is not published in the county's data.