2demerits
GREENS AT BIRKDALE
17229 BRIDGETON LANE, Huntersville, NC 28078
Seasonal Swimming Pool · NC permit/State ID 2060500908
Latest result2 demerits
Last inspectedApr 16, 2026
Inspections on record13
On record sinceJun 9, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jun 9, 2014Lower is betterApr 16, 2026
Inspections & violations
Apr 16, 2026 2 demerits · 1 violation
Inspector comments: 5% flow meter was verified / new PDSC form approved for 2026 season.
Restriction: Flow meter must remain operable. Flow shall not exceed 295 gpm due to flow through skimmers. Flow greater than 500 gpm exceeds the main drains. Suction Hazard.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed standing water in chemical storage room.
Apr 16, 2025 10 demerits · 2 violations
Inspector comments: PERMIT RESTRICTIONS
Flow not to exceed 295GPM due to amount of skimmers;
200 gpm observed and verified during inspection.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8.Observed pool pH measuring 8.4 during inspection; CDI pool pH corrected during inspection to 7.8.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmer boxes in need of cleaning with large amounts of accumulation observed.
Apr 4, 2024 16 demerits · 5 violations
Inspector comments: Inspection conducted with operator Luke Fiser and Steve Edmunds. All permit items in compliance by end of inspection. Permit issued.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Heavy debris buildup in skimmer baskets. Operator cleaned during inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Ladder at far end of pool near parking lot loose. Operator corrected.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy. Ring buoy with fraying rope. Operator replaced during inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Bag of dry chemicals stored on floor in pump room. Multiple buckets/containers of other chemcials stored in pump room chemical storage room is provided - provide clear walkway around equipment. Pool build 2000.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. Unable to determine if restroom mirrors are shatterproof.
Apr 12, 2023 8 demerits · 3 violations
Inspector comments: 22. Phone has a lot of static-recommend replacing; provide directional sign to emergency phone visible from pool deck
24. Flow meter operable at time of inspection
25. Store chemicals off the floor, provide clear walkway around equipment
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Keep baskets free of debris
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Store chemicals off the floor, provide clear walkway around equipment
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Mirrors to be of shatterproof construction
Apr 21, 2022 4 demerits · 1 violation
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed no pool records book. CDI: CPO provided.
May 4, 2021 24 demerits · 5 violations
Inspector comments: Night swimming is NOT permitted.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed PH level at 7.0. Corrected to 7.3 during inspection.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed daily pool records not recorded for today’s inspection. CDI: today’s records were written in pool log book.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed both throw ropes length > 50ft. CDI: ropes were cut to 50ft during inspection.
#22 · Premises: emergency telephone provided −6
.2530(f) Provide signage with location of emergency phone if not visible from all areas inside pool enclosure. No signage observed for location of emergency phone. CDI: directions for location of emergency phone was written in on pool rules sign.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. Mirrors not shatterproof in restrooms.
May 13, 2020 16 demerits · 3 violations
Inspector comments: Night swimming is not permitted.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
One equalizer line was plugged in the skimmer. Corrected during inspection.
#22 · Premises: emergency telephone provided −6
Emergency phone sign not posted with number and address. Corrected during inspection.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
One inlet was stuffed with trash. Corrected during inspection.
May 9, 2019 28 demerits · 6 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Pool floor needs vacuumed in some spots. Keep pool floor clean and free of debris.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
4 out of 9 weirs missing. 2 of the 4 were corrected during inspection.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
One equalizer line plugged. Corrected during inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
One body hook missing. Pool must have two at all times. Corrected during inspection.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Pump does not have an extra strainer basket. Corrected during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Fence has >2" gap but <4" gap between ground surface and bottom of fence.
Apr 4, 2018 4 demerits · 1 violation
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed some minor cracking around the pool decking
Apr 26, 2017 4 demerits · 1 violation
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed sections of the deck drain sticking up which may cause a trip hazard.
Jul 6, 2016 8 demerits · 3 violations
Inspector comments: 22. Post additional signage for location of emergency phone-phone not visible from pool deck
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Record total alkalinity & cyanuric acid 1 x week, recored main drain grate check daily
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Natural cross or continuous forced ventilation required
#32 · Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean −2
Floors to be slip resistant
Jun 18, 2015 12 demerits · 4 violations
Inspector comments: Inspection report received by Jonathon Goebelt
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Record cyanuric acid 1 x week
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Keep baskets free of debris
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Continuous forced or natural cross ventilation required
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Backflow preventer required on hose bib
Jun 9, 2014 10 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmers shall be clean and in good repair with no floating debris. Observed floating debris in skimmers and 3 weirs missing. Clean and repair.
#22 · Premises: emergency telephone provided −6
Emergency telephone shall have a sign posted with pool information and dialing instructions. Observed sign for emergency phone not posted with phone. CDI-sign moved to above phone for easier locating.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “GREENS AT BIRKDALE” or State ID 2060500908). Inspection type (routine vs. follow-up) is not published in the county's data.