16demerits
LATITUDE 49
901 FORTY NINER AVENUE, Charlotte, NC 28262
Seasonal Swimming Pool · NC permit/State ID 2060500909
Latest result16 demerits
Last inspectedMay 22, 2026
Inspections on record13
On record sinceMay 5, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
May 5, 2014Lower is betterMay 22, 2026
Inspections & violations
May 22, 2026 16 demerits · 4 violations
Inspector comments: PERMIT RESTRICTIONS:
- Flow meter must remain operable. Flow required 165 GPM to 172 GPM to meet turnover and flow restriction of the filters.
NOTE:
- No Night Swimming permitted.
- CPO: Giovanni Avila present during permitting inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.- Observed rope length is too long. CPO cut a rope and measured at 50ft at the time of inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.- Observed fences around the pool, some part measured at 45ft -46ft in height.
***NOTE: Pool was constructed 8/1/2000.***
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm.- Observed one of the door leading out to pool deck is not self latching. Fixed during the inspection.
.2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm.- Observed all windows leading out to pool deck are able to open wide. Fixed during the inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times.- Observed pool furniture are placed to close to the edge of pool. Furniture rearranged at the time of inspection.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(a) Post a shower sign visible upon entrance to the pool.- Observed no shower sign. A sign posted at the entrance at the time of inspection.
Jul 15, 2025 6 demerits · 1 violation
Inspector comments: Permit issued
Pentair SuperFlow VST, 342002 2.2THP and Pentair WhisperFlo VST, 011533, 2.6 HP pumps were verified during inspection. Drain covers, number of returns, number of equalizer lines (5) equalizer drain covers, and pipe diameters in pump room verified during inspection.
No night swimming permitted
Permit restriction: Flow meter must remain operational and flow must be 165-172 gpm
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Phone number was not posted at emergency phone. CDI - Manager printed out label with phone number and placed it on phone during inspection.
May 20, 2025 16 demerits · 4 violations
Inspector comments: Permit denied due to most weirs missing in skimmers, door to pool deck from leasing office does not audibly alarm, and the filtration pumps have been replaced with new make/model pumps and PDSC form has not been reviewed or approved by department.
Contact Mecklenburg County Environmental Health when listed items are remedied to pay pool revisit fee and to schedule inspection again.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Pumps have been replaced with new make and model pumps. Permit can’t be issued until it is reviewed and approved by Senior EHS. Permit denial item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. 3 out of 4 weirs missing in skimmers. Replace missing weirs. Permit denial item.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). More than 2 inch gap between fence and ground. REPEAT
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Alarm was not functioning from door to pool deck from leasing office.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Floor of pump room is wet. Ensure there are no leaks in pump room.
May 6, 2024 26 demerits · 5 violations
Inspector comments: PO stated that the water was not turned on therefore the showers dis not turn on.
Permit not issued today
Call 980-314-1620
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine at .4 ppm
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH 7.0
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). Observed areas of fence with greater than 2 inches under it.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
2537.(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed multiple areas of pool deck with offsets greater than 1/2”.
#22 · Premises: emergency telephone provided −6
2530.(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed the kingsIII phone does not have the emergency sign with the address and phone number posted. Facility also has 2 other mounted emergency phone boxes and need to remove those unused phone boxes.
May 24, 2023 32 demerits · 6 violations
Inspector comments: .2535(2) Main drains must be clearly visible from the pool deck. Observed main drains not visible.
.2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine 0.4.
.2523(d) No Diving markers shall be written in four inch letters or international 6"x6" no diving in red and black on a white background. No diving marker was cracked and ripping needs to be replaced.
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed vacuum line cap easily openable on pool wall. Needs to be secured.
.2530(a) Pole for body hook must be non-telescoping, non-adjustable, and non-collapsible. Observed body hook on adjustable pole. Needs to be non-adjustable.
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed no signage for pool address and phone number. Observed 911 did not have address and phone number of pool.
#1 · Water quality: water clear enough to clearly see bottom of pool and pool drain −6
.2535(2) Main drains must be clearly visible from the pool deck. Observed main drains not visible. PERMIT DENIED.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine 0.4.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(d) No Diving markers shall be written in four inch letters or international 6"x6" no diving in red and black on a white background. No diving marker was cracked and ripping needs to be replaced.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed vacuum line cap easily openable on pool wall. Needs to be secured.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Pole for body hook must be non-telescoping, non-adjustable, and non-collapsible. Observed body hook on adjustable pole. Needs to be non-adjustable.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed no signage for pool address and phone number. Observed 911 did not have address and phone number of pool. PERMIT DENIED.
May 26, 2021 14 demerits · 3 violations
Inspector comments: pool failed pre-permit inspection due to three issues. Emergency phone did not work. No dial tone. PDSC form showed 4 equalizer/skimmers, pool actually had 5.
A depth marker was missing.
To re-apply for a pool inspection correct the above issues, including updating the PDSC form. Pay $100.00 dollar re-visit fee.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(a) Provide depth markers on pool walls and pool deck next to the swimming pool.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2543 The surge container for interactive play attractions shall be kept accessible and shall maintain an operable surface skimmer.
Apr 27, 2021 6 demerits · 2 violations
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
pool light not properly secured. Corrected during inspection
#27 · Equipment room: filter backwash discharged through an air gap −2
no air gap for backwash
May 2, 2019 18 demerits · 4 violations
#2 · Water quality: disinfectant residual provided by −6
Observed chlorine at 0.4ppm at the start of the inspection. Chlorine was added during the process of the inspection. Chlorine registered at 10ppm by the end of the inspection.
**.2535(4) Maintain chlorine at least 1.0 ppm.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed two weirs missing in the pool. Wiers were replaced during the inspection.
**.2518(k) Replace missing weirs.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed ring buoy torn. Corrected during the inspection: buoy was replaced.
**.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed water temperature at 114F in the women's restroom. Needs to be reduced.
**.2626(i) Water in restrooms shall not exceed 110 F.
May 15, 2018 4 demerits · 1 violation
Inspector comments: Pool permit issued. Permit no. 18-600546
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed a rail next to fence approx. 37" tall that could be used as a foot hold. Need section of 48" fence height from height of foot hold.
Apr 5, 2017 8 demerits · 2 violations
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed a 37.5" rail next to the fence; rail could be used as a foot hold.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed a lounge chair 5 ft from the edge of the pool. - Corrected during inspection: the chair was moved to at least 6ft away from the edge of the pool.
Jul 7, 2016 10 demerits · 3 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
observed floating debris in surface skimmers. CDI
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
observed sections of pool fence < 48" tall. no action needed by CPO at this time.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
observed water leaking onto floor under 1 pump. repair
*Permit reinstated. Assigned 'A' status.
Apr 22, 2015 2 demerits · 1 violation
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed no paper towles in the women's restroom. **keep the restrooms sinks supplied with soap and paper towels.General Comments: Dereck Hutchins was present during the inspection.The pool permit will be available for printing at the following website in 3 business days once PDSC form is approved: meckpools.charmeck.org
May 5, 2014 18 demerits · 4 violations
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Observed two depth markers 25 ft, 3 inches apart. Install another depth marker at tennis court side of pool (between 4 ft and 5 ft section on pool deck and pool wall so that depth markers are 25 ft or less apart. Observed one depth marker missing "ft". corrected during inspection
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed some parts of fence less than 48 inches in height. Observed some vertical fence members greater than 4 inches apart. Provide a fence that is 48 inches in height with no openings greater than 4 inches. Observed tennis court side of fence loose. Secure the fence.
#22 · Premises: emergency telephone provided −6
Emergency phone did not have the correct phone number. Corrected during inspection, operator updated phone sign with correct phone number.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed small water fill line with no cover (Deep end of pool). Install a cover