‹ Back to search

2demerits

CAMDEN GRANDVIEW

309 E MOREHEAD ST, Charlotte, NC 28202
Seasonal Swimming Pool · NC permit/State ID 2060500915
Latest result2 demerits
Last inspectedApr 16, 2026
Inspections on record15
On record sinceApr 10, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01326 Apr 10, 2014: 0Apr 28, 2015: 12Apr 28, 2016: 0Mar 23, 2017: 4Apr 3, 2018: 22May 1, 2019: 0May 7, 2020: 0Apr 8, 2021: 16Apr 27, 2022: 4May 31, 2023: 6Jun 1, 2023: 0Apr 9, 2024: 4Apr 2, 2025: 26May 22, 2025: 4Apr 16, 2026: 2
Apr 10, 2014Lower is betterApr 16, 2026

Inspections & violations

Apr 16, 2026 2 demerits · 1 violation
Inspector comments: Permit Restriction: Flow meter must remain operable. Flow shall be maintained as close to but not exceeding 63 GPM due to filter flow restriction. Flow greater than 188 GPM exceeds the main drains. Suction hazard. If clarity becomes an issue filter may require change to allow for increased flow throughout the system. NOTE: Night swimming not allowed
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. - Observed rubber caps missing on ladder.

View this inspection on the county portal ›

May 22, 2025 4 demerits · 1 violation
Inspector comments: Front gate repaired and self-closes and self-latches. Emergency phone was functioning. Flow meter installed and operating. No night swimming Permit restrictions: Flow meter must remain operable and flow must not exceed 63GPM Drain covers and filtration pump verified during inspection from PDSC form Permit issued
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Some debris in skimmers. Clean skimmers of debris.

View this inspection on the county portal ›

Apr 2, 2025 26 demerits · 6 violations
Inspector comments: Permit denied due to emergency phone being inoperable, front gate not self-closing, and flow meter not functioning. These must be repaired before permit can be issued. Contact Mecklenburg County Environmental Health at 980-314-1620 to pay revisit fee once the emergency phone, front gate and flow meter are repaired.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Debris observed on pool. Vacuum debris out of pool.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Heavy debris in skimmers.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Front gate does not self-close. Gate must be repaired so it self-closes before permit will be issued.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Crack present in pool deck beside ladder. Repair crack.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Emergency phone is not operable. Emergency phone was be functional before permit will be issued.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter is not functioning. Pool has permit restriction stating that the flow meter was must operable at all times. Flow meter must be functioning before permit can be issued.

View this inspection on the county portal ›

Apr 9, 2024 4 demerits · 1 violation
Inspector comments: Verified pump and main drains during the inspection. Night swimming prohibited.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed posted planted less than 6 ft from the pools edge. CDI - potted Plant moved.

View this inspection on the county portal ›

Jun 1, 2023 0 demerits · 0 violations
Inspector comments: No violations noted. NIGHT SWIMMING NOT PERMITTED.

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 31, 2023 6 demerits · 1 violation
Inspector comments: Submit updated PDSC form to Katie Rudisill (Katie.Rudisill@mecklenburgcountync.gov). Once new PDSC form is approved, contact main office at 980-314-1620 to pay $100 re-inspection fee. EHS will call to schedule re-inspection once re-inspection fee has been paid.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. - Observed main drain covers listed on PDSC form to not match drain covers installed in pool. Permit denied until updated PDSC form received and approved.

View this inspection on the county portal ›

Apr 27, 2022 4 demerits · 1 violation
Inspector comments: Pool operating hours: dawn to dusk. No night swimming visit required.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Large pot of flowers obstructed 6 feet of deck clearance. CDI- Moved.

View this inspection on the county portal ›

Apr 8, 2021 16 demerits · 4 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy. Ring Buoy was not USCG approved. CDI- USCG approved ring buoy obtained.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. One set of door swinging into pool was self closing but did not set off an alarm. CDI- Adjusted and alarm went off when door was opened.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Large pot of flowers obstructed 6 feet of deck clearance. CDI- Moved.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
.2518(d) Piping and valves shall be labeled with color codes or labels. No labels on piping.

View this inspection on the county portal ›

May 7, 2020 0 demerits · 0 violations
Inspector comments: “Due to COVid19 and public health responsibility, safe distancing and minimizing point of contact, inspection will not be signed as agreement"

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 1, 2019 0 demerits · 0 violations
Inspector comments: Pool operator stated that complex does not do night swimming. The pool closes at 8pm. General comment: Observed no extra basket for the filter.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 3, 2018 22 demerits · 6 violations
Inspector comments: Note: Main drain covers, Paramount SDX Retro expire May 2019 Pool Hours indicate "Night Swimming" (open until 11 p.m.) Permit will not permit ‘Night Swimming’ until an onsite visit is conducted before dawn or after dusk to meet compliance with new regulation. It can still be open during daylight without an onsite visit. This includes: Pool illumination is sufficient to illuminate the main drains of the pool and the deck area of the pool so that it is visible at all times the pool is in use. Lighting fixtures are of such number and design to illuminate all parts of the pool, the water, the depth markers, signs, entrances, restrooms, safety equipment and the required deck area and walkways. The illumination is sufficient so that the floor of the pool can be seen at all times the pool is in use. Please contact Marie Daley 704-507-6806 directly to schedule a visit to verify lighting is sufficient and this condition is met to update permit to allow ‘Night Swimming’. Permit issued.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder missing rubber cap. Replace and keep in good repair.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Open pipe vacuum port protruding greater than 2" from pool wall. Piece removed, creating hole with no cover. Keep in good repair and prevent hazards. Operator plugged. Corrected.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Body hook inaccessiable due to chairs. Keep accessible in case of emergency. Operator moved chairs for accessibility. Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gate with anchor bar that was able to be moved and did not self-close self-latch. Gates must self-close, self-latch unless kept locked. Operator installed mechanism to keep side gate locked. Corrected. Multiple doors from building onto pool deck did not self-close, self-latch or have audible alarm. Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Operator installed audible alarms on ground level doors that were not in compliance. Corrected.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Chairs within 6' of pool. Provide 6 ft of clear walking space around the pool at all times. Moved chairs. Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Leak in pump room. Pump room floor shall be kept dry and free of standing water.

View this inspection on the county portal ›

Mar 23, 2017 4 demerits · 1 violation
Inspector comments: Inspection conducted with Neil Wiltshire. 8. .2518 Keep skimmer baskets clean and in good repair. Observed skimmer baskets soiled with debris.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522 Outdoor pools should have a 6 ft clearance around all points. Observed small chairs on pool deck create less than a 6 ft clearance.

View this inspection on the county portal ›

Apr 28, 2016 0 demerits · 0 violations

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 28, 2015 12 demerits · 3 violations
#3 · Water quality: pool water pH −6
pH 6.8. Maintain between 7.2 and 7.8. Corrected to 7.4.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Both equalizer lines plugged. Remove plugs to provide functional equalizers. Corrected by operator.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
No light in chemical storage room. Provide lighting.

View this inspection on the county portal ›

Apr 10, 2014 0 demerits · 0 violations
Inspector comments: Recommended to maintain pH between 7.2 and 7.8. Currently at 7.2. Mark Thomason present.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “CAMDEN GRANDVIEW” or State ID 2060500915). Inspection type (routine vs. follow-up) is not published in the county's data.