4demerits
HUNTER DOWNS
9535 TERRIER WAY, Charlotte, NC 28269
Seasonal Swimming Pool · NC permit/State ID 2060500916
Latest result4 demerits
Last inspectedMay 21, 2026
Inspections on record12
On record sinceJun 24, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jun 24, 2014Lower is betterMay 21, 2026
Inspections & violations
May 21, 2026 4 demerits · 1 violation
Inspector comments: Flow meter to remain operable. Flow set at 92-98 GPM to meet turnover and flow. Flow not to exceed 118 gpm. Suction Hazard.
No night Swimming.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed one missing weir. Replace.
May 19, 2025 8 demerits · 2 violations
Inspector comments: No night swimming.
Flow meter must remain operable.
Flow to be set between 92 and 98gpm to meet turnover.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Pine needles observed on pool floor. Cleaning in progress.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Pine needles in skimmers, cleaning in progress.
May 22, 2024 2 demerits · 1 violation
Inspector comments: Pool is not permitted for night swimming.
Backwash was observed during inspection prior to flow meter reading.
The following items were field verified:
Permit Restriction: Flow meter must remain operable. Flow set at 92 gpm to 98 gpm to meet turnover and flow restriction of filter. FlowVis flow meter installed.
New Pump Pentair WhisperfloVST, 011533, 2.6 THP
Main drain, skimmer are 3” and return line is 2”
(2) Aquastar 2017 A10RCFRxxx main drains
(4) skimmers with Aquastar 6HPHAxxx EQ line covers
(1) Pentair TR100C filter
6 returns, either on the floor or wall
Pump speed set at 2800 rpm
All items were in compliance and matched PDSC form.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521(b) Ladders shall have slip-resistant tread. Observed one step on ladder missing slip resistant tread. Replace or repair.
May 16, 2023 2 demerits · 1 violation
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(m) Keep restrooms and fixtures clean and in good repair. Observed detailed cleaning needed to toilet fixtures and handwashing sinks in both men and women restrooms.
May 18, 2022 2 demerits · 1 violation
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
No backflow preventer. CDI backflow preventer installed.
May 24, 2021 12 demerits · 3 violations
Inspector comments: Night swimming has not bee approved.
Pierce Sawyer was the pool operator onsite during the inspection. No Signature provided due to COVID 19.
Issuance of the permit by this Department does not negate meeting requirements of Executive Order 195 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
Observed buildup to the inside of the skimmer baskets. This was corrected and they were properly cleaned.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
Observed damage to the deck at the stairs entrance to the pool. This was corrected and concrete was added to create a smooth surface and no trip hazard.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational.
Observed bobber to the flow meter not properly operating. This was corrected and the flow meter was repaired to allow for the bobber to properly float where needed.
May 17, 2019 12 demerits · 3 violations
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
depth markers were faded. CPO corrected during inspection
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
ring buoy in disrepair. CPO replaced ring buoy and rope
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
shower before entering sign missing. CPO put up new sign.
May 23, 2018 4 demerits · 2 violations
Inspector comments: PDSC Information verified. No night swimming.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed hose bib without backflow prevention device. .2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room.
Observed light not working in pump room. .2533(b) Provide sufficient lighting in pump room. CDI: Operator found that breaker was not on and turned on.
Observed pump room floor wet. .2533(d) Pump room floor shall be kept dry and free of standing water.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed baseboards hanging off of womens restroom walls. Complete repairs. .2626(m) Keep restrooms and fixtures clean and in good repair.
Jul 18, 2017 14 demerits · 6 violations
Inspector comments: 9: Several depth markers are faded and need to be re-spray painted
18. Sign is starting to fade, recommend replacing
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Replace tread on ladder-rubber non-slip piece missing
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Fill in section of deck by the women's restroom-trip hazard
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Lights not working, natural cross or continuous ventilation required
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Remark labels, they are faded
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Mirrors to be of shatterproof construction, lights not working, repairs need to be finished
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Backflow preventer required on hose bibs
Jul 19, 2016 6 demerits · 3 violations
Inspector comments: 6.) Pump information is incorrect on PDSC form. PDSC form says pump is a Hayward Super Pump 2, 1.5 HP. Actual pump is a Hayward RS series 1500, 1.5 HP. Submit new PDSC form by end of day to avoid permit action. If not submitted by end of day permit will be suspended. All other PDSC information has been verified and is correct.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed backwash pipe level with floor of backwash pit. Provide sufficient air gap at backwash.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed mirrors in both restrooms are not shatter resistant. Provide.
#32 · Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean −2
Observed baseboards in women's restroom peeling away from wall. Repair.
Jun 16, 2015 8 demerits · 3 violations
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed table and chairs closer than 6ft to edge of pool. Corrected during inspection - table and chairs were relocated.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed air gap right at height of floor. Provide air gap for backwash. Recommended cutting off 1" - 2" at bottom of pipe.
#32 · Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean −2
Observed baseboards in women's restroom peeling away from wall. Reattach baseboards.
Jun 24, 2014 10 demerits · 4 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Maintain daily records, total alkalinity and cyanauric acid readings should be at least every 7 days. Observed some gaps of time more then 7 days without total alkalinity or cyanauric acid recorded. CD- Corrected by instruction.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
One non slip tread missing from ladder.
#27 · Equipment room: filter backwash discharged through an air gap −2
Need air gap from backwash pipe above height of pit - CDI.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No lighting in restrooms due to electrical problem. Need to provide adequate lighting. Baseboards are falling off walls, need replacing. Mirrors should be shatterproof.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “HUNTER DOWNS” or State ID 2060500916). Inspection type (routine vs. follow-up) is not published in the county's data.