STONE GATE

950 SOUTHWOOD OAKS LANE, Charlotte, NC 28212
Seasonal Swimming Pool · NC permit/State ID 2060500925
Latest result2 demerits
Last inspectedJun 24, 2026
Inspections on record11
On record sinceJun 17, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01836 Jun 17, 2014: 0Jul 23, 2015: 18Jun 16, 2016: 4Jun 14, 2017: 0May 23, 2018: 8May 21, 2019: 16Apr 19, 2024: 36Apr 24, 2024: 8May 28, 2025: 20Jun 5, 2025: 12Jun 24, 2026: 2
Jun 17, 2014Lower is betterJun 24, 2026

Inspections & violations

Jun 24, 2026 2 demerits · 1 violation
Inspector comments: Inspection conducted with Israel Rivas. No night swimming. PERMIT RESTRICTION: flow meter must remain operable. Flow required at 57 gpm to 80 gpm to meet turnover and flow restriction of number of returns. Flow greater than 119 gpm exceeds the main drains. Suction hazard.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521(b) Ladders shall have slip-resistant tread. Observed missing slip resistant tread on top step of ladder. Replace missing tread.

View this inspection on the county portal ›

Jun 5, 2025 12 demerits · 4 violations
Inspector comments: NO NIGHT SWIMMING. PERMIT RESTRICTION: FLOW METER MUST REMAIN OPERABLE. FLOW REQUIRED AT 57GPM TO 80GPM TO MEET TURNOVER AND FLOW RESTRICTION OF NUMBER OF RETURNS. FLOW RESTRICTION OF DRAIN COVERS AT 119GPM.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmer basket with debris. CPO dumped basket during inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521(b) Ladders shall have slip-resistant tread. Observed ladder missing slip resistant tread on top step. Replace.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed lounge chairs within 5 feet of pool water. Chairs were pushed back to allow for 6 feet of deck space.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Unable to determine if ventilation fan in chemical room is operating.

View this inspection on the county portal ›

May 28, 2025 20 demerits · 5 violations
Inspector comments: Permit denied. For Re-inspection call Main office at 980-314-1620. Re-inspection fee is required.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Observed skimmer closest to ladder without equalizer line plugged. PDSC form states equalizer lines are plugged per state recommendations. Permit denied
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(d) No Diving markers shall be written in four inch letters or international 6"x6" no diving in red and black on a white background. Observed no diving markers with plaster covering up part of the markers. Markers are stickers and are starting to peel up. Permit denied.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521(b) Ladders shall have slip-resistant tread. Observed slip resistant tread missing on top step of ladder.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed facility with the incorrect phone number on heavily damaged sign. Sign is also not posted near emergency phone. Permit denied.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Unable to determine if ventilation fan in chemical is operating.

View this inspection on the county portal ›

Apr 24, 2024 8 demerits · 3 violations
Inspector comments: Inspection conducted with property manager Amber. All permit items in compliance. Permit issued. Verified the following items: Flow verified at 65 gpm Pentair Itelliflow VSF 011056 pump installed Flow meter operational Skimmers and weirs operational Disinfectant provided through in line chlorinator at proper ppm Windows limited to 4” Depth and no diving markers in compliance Ring buoy rope in compliance Signed permit and sticker provided during inspection.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some minor damage to concrete coping at pool stairs and at 5’ end of pool. Minor tile damage near grate fitting in 3’ area. No permit action at this time, however, repair may be needed by next operating season.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Chemical storage room mechanical ventilation not operational. Unable to determine operation of ventilation in pump room.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Pipework for backwash has been re-worked and elbows down into backwash pit - no air gap present.

View this inspection on the county portal ›

Apr 19, 2024 36 demerits · 9 violations
Inspector comments: NOTE: OPERATOR UPDATED TO MARQUIS DAVIS CPO# - C-082960 EXP 3/31/2029. PERMIT DENIED DUE TO THE FOLLOWING ITEMS: .2523 (C) - DEPTH MARKERS .2528 (D) - NO DIVING TILES .2528 (A) - WINDOWS NOT LIMITED .2518 (G) - INOPERABLE FLOW METER - UNABLE TO ASSESS FLOW RESTRICTION GS130(A) - Manual addition of chlorine tablets to pool Once all items corrected, call the office at 980-314-1620 to request a re-inspection. A $100 return visit fee will apply. Inspection conducted with operator Marquis and manger Amber.
#2 · Water quality: disinfectant residual provided by −6
G.S. 130A-2(3) Chlorine added directly to swimming pool. Chlorination must occur through chlorinator. Eliminate direct hazard to public. Observed chlorine tablets in skimmer basket. Operator advised pool company directed her to add tablets to pool directly in addition to using skimmer. All chlorine added to pool must be through chlorinator. Do not add chlorine to pool unless “shocking” and pool is closed for swimming. *permit item
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some minor damage to concrete coping at pool stairs and at 5’ end of pool. Minor tile damage near grate fitting in 3’ area. No permit action at this time, however, repair may be needed by next operating season.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Surface skimmers shall be installed per manufacturer's instructions. Weir in one skimmer installed improperly blocking water flow subsequently detached. Repair.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(c) Depth markers shall be 4 inches in height and of a contrasting color with the background, clearly visible. Multiple depth markers on pool walls significantly faded. *Permit item .2523(d) No Diving markers shall be provided in all areas of the pool less than five feet deep. Distances between multiple no diving tiles on pool deck exceed 25’ *Permit item
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy rope greater than required 29’. Corrected to 29’ during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. Three windows leading from clubhouse directly onto pool deck open fully. Windows that open directly onto pool deck must be limited to open no more than 4”. *Permit item
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter not operational. Permit condition exists requiring operable flow meter due to pump change out and installation of new variable speed pump. Flow meter must remain operational. *permit item
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Chemical storage room mechanical ventilation not operational. Unable to determine operation of ventilation in pump room.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Pipework for backwash has been re-worked and elbows down into backwash pit - no air gap present.

View this inspection on the county portal ›

May 21, 2019 16 demerits · 4 violations
Inspector comments: PDSC form reviewed and CPO was present for inspection.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Observed test kit provided with several reagents expired. CDI. CPO was able to obtain a new test skit by end of inspection.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(d) No Diving markers shall be provided in all areas of the pool less than five feet deep. .2523(d) The distance between no diving markers shall be no more than 25 feet perimeter or as the crow flies. Observed missing no diving markers on far side of pool in areas less than 5 ft deep. Per CPO, they were removed when deck was repainted. CDI. CPO was able to obtain depth markers and install during end of inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Rope was measured more than required length of 29ft. CDI. The CPO cut the rope to 29 ft.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2626(j) Provide soap and soap dispenser, no glass, at each sink. No soap provided in restrooms.

View this inspection on the county portal ›

May 23, 2018 8 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
1 weir missing. CDI weir replaced during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gate was not self closing. CDI gate latch was fixed during inspection, gate is now self closing/ self latching.

View this inspection on the county portal ›

Jun 14, 2017 0 demerits · 0 violations
Inspector comments: All inspection items correct.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Jun 16, 2016 4 demerits · 1 violation
Inspector comments: Cut limbs back around gate so it will self latch. CDI
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck.

View this inspection on the county portal ›

Jul 23, 2015 18 demerits · 5 violations
#3 · Water quality: pool water pH −6
Observed pH to be at 6.8 or lower. pH must be 7.2-7.8 for safe swimming. I.S. Issued. Pool must be closed for swimming until pH is corrected. Contact C. Elmore at 704-507-6814 when pH is corrected.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Observed "NO DIVING" markers on the deck to be greater than 25 feet apart. This is due to some markers being removed and some being the incorrect type of marker. Markers must be either the 6"x6" tile with the red, white, and black international symbol, or they must be written in letters that are at least 4" high.
#18 · Premises: lifeguards present or warning signs posted −4
Observed incorrect sign for "CHILDREN SHOULD NOT USE THE SWIMMING POOL WITHOUT ADULT SUPERVISION." The sign is improperly worded. Provide properly worded sign with letters that are at lease 4" high.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed no backwash air gap.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Observed no shower sign posted.

View this inspection on the county portal ›

Jun 17, 2014 0 demerits · 0 violations

No violations were recorded for this inspection.

View this inspection on the county portal ›