Apr 21, 2026 2 demerits · 1 violation
Inspector comments: No night swimming being conducted
Inspection conducted with CPO Richard Micham
Permit Restriction: Flow meter must remain operable with min flow at 177 gpm. Pump has single speed motor - no longer variable
speed; however, has model of variable speed on housing. Pump at max flow.
5hp motor installed no change to pump . pump is not meeting turn over. If clarity issues occur the pump will need to be change.
Minimum flow of 177 gpm was not observed in the field. Water clarity is still good. Pool still allowed to operate.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
25 Observations and Corrective Actions
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.
Observed bags of pool chemicals being stored directly on the floor.
-CDI- Chemicals were placed off of the floor.
May 8, 2025 14 demerits · 3 violations
Inspector comments: No night swimming being conducted
Inspection conducted with CPO Richard Micham
Permit Restriction: Flow meter must remain operable with min flow at 177 gpm. Pump has single speed motor - no longer variable speed; however, has model of variable speed on housing. Pump at max flow.
5hp motor installed no change to pump . pump is not meeting turn over. If clarity issues occur the pump will need to be change.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed 1 out of 6 weirs missing. CDI - CPO replaced repair.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(10) Diving equipment and pool slides including stairs and railings shall be kept in good working order. Observed ladders near 5ft deep area not secured and loose to touch. CDI - CPO was able to secure ladder to ground.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope at 52FT. CDI - CPO reduced rope to 50FT
Jun 27, 2024 14 demerits · 4 violations
Inspector comments: No night swimming being conducted
Inspection conducted with CPO Mikey Cook
Permit restrictions: Pump required locked at 3450 RPM due to turnover. Flow meter must remain operable. Minimum flow is 177 gpm.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed PH at 7.0. CDI: corrected to 7.2 - 7.4 during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed some openings under chain link fence > 4”. CDI: fixed by CPO during inspection.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(j) Provide soap and soap dispenser, no glass, at each sink. Observed no soap available in women’s restroom.
.2526(k) Provide shatterproof mirrors. Observed no documentation of mirrors in restrooms being shatterproof.
.2526(m) Keep restrooms and fixtures clean and in good repair. Observed lights not working in restrooms. Was able to verify all other items in compliance. All other lights at pool working properly. Lights getting repaired before end of week. CPO will send a picture of lights fixed.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
.2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. Observed deck hose without back flow preventer. CDI: back flow preventer on site but just needs to be installed.
May 29, 2024 18 demerits · 4 violations
Inspector comments: Inspection conducted with CPO Mikey
Permit denial due to emergency phone not dialing back to pool deck when called. Receiving error message from Verizon Wireless saying “Number cannot be completed as dialed”.
Contact main office at 980-314-1620 and pay $100 reinspection fee prior to scheduling another inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope length on ring buoy measuring 60ft. CDI rope cut to required 50ft.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed some openings under chain link fence > 4”.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone. Observed phone number not dialing back to pool phone number when called. Permit denial.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(j) Provide soap and soap dispenser, no glass, at each sink. Observed no soap available in women’s restroom.
.2526(k) Provide shatterproof mirrors. Observed no documentation of mirrors in restrooms being shatterproof.
Apr 4, 2023 10 demerits · 2 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed pool flooring having build-up debris accumulated in need of general cleaning.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope length on ring buoy measuring 60ft. CDI rope cut to required 50ft.
Apr 14, 2022 0 demerits · 0 violations
Inspector comments: No issues with the pool, permit given
No violations were recorded for this inspection.
Jul 6, 2021 8 demerits · 2 violations
Inspector comments: Permit conditioned such that the pump must be maintained at 3450 RPM to operate, as required to reach proper turnover rate.
No Night swimming
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed 60 foot thow rope, cut to 50 feet as required.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed chemical bags stored on the floor of the pump room, items moved to the chemical room, and kept 6 inches off the floor
Jun 5, 2020 4 demerits · 1 violation
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. - Observed pool debris on pool floor.
May 17, 2019 8 demerits · 2 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed no record log. CPO provided record log during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed a couple spaces below fence that were greater than 4 inches. Pool was constructed pre-2010.
Apr 11, 2018 16 demerits · 5 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
(.2518, .2537)- Observed skimmer baskets with minor debris. CDI- CPO cleaned baskets.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
(.2517, .2521)- Observed ladders on each end of the pool loose and in need of tightening.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
(.2528, .2537)- Observed several areas of fence with six inch gaps. One area near 5 foot end and another area near pump room. CDI- CPO managed to flex the fence to correct the gaps.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
(2518, .2519)- Observed flow meter non functional. CDI- CPO managed to repair the item by the end of the inspection. EHS observed functioning flow meter.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
(.2512)- Observed several hose bibs on the pool deck and near showers without a back flow prevention device.
CPO- Danny Richards was present during the inspection.
Meck county permit number: 18-601068
May 11, 2017 10 demerits · 4 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Clean pool wall. Repair (1) wall tile near steps entering swimming pool.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed ventilation connected to light switch. Ventilation in chemical room shall be continuous and not connected to light switch. Repair ventilation or provide cross ventilation in pump room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Thoroughly clean bathroom fixture in both men and women bathroom/dressing room.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Provide back flow prevention device on hose bib on pool deck.
May 17, 2016 2 demerits · 1 violation
Inspector comments: 22. General Comment -- Update emergency phone sign if phone is to remain inside office to note actual location.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
No backflow prevention installed on exterior hose bibs -- Install
Jun 18, 2015 32 demerits · 10 violations
Inspector comments: Intent to Suspend issued for #9 and #11
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Etching on pool floor. Repair plaster.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One weir stuck. Repair.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
26.5 ft between 3 ft depth markers. Provide every 25 ft or less. Intent to Suspend issued.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
>75 ft between ladders. One missing. Replace. Intent to Suspend issued.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Rope at 48 ft. Corrected to 50 ft.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
PVC leaking on both pumps. Repair where needed.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Floor wet under pumps. Keep dry.
#27 · Equipment room: filter backwash discharged through an air gap −2
Pipe in backwash pit not cut flush so standing water. Cut flush.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
One sink in women's not operable. Repair.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
No backflow prevention device on hose bibs. Provide backflow prevention device.
Jun 17, 2014 20 demerits · 5 violations
Inspector comments: #17 Observed deck cracks. **patch as needed.
GC #25 Leak @ one filter. **resolve.
GC #30 Observed at least 3 hose bibs without back flow prevention. **install vacuum breakers on these hose bibs.
Intent to Suspend issued for #5 & #9.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Missing daily main drain checks. **check & record. ITS.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
NO DIVING markers faded. **re-paint. ITS.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Handrail & 1 ladder loose. **secure.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Rope on ring buoy ~47' long. **rope replaced with 50' while on-site.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. **resolve.
Jul 19, 2013 2 demerits · 1 violation
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
OBSERVED ONE LOOSE HANDRAIL AND ONE LOOSE LADDER. / TIGHTEN
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “OAKDALE GREEN” or State ID 2060500929). Inspection type (routine vs. follow-up) is not published in the county's data.