8demerits
MADISON PARK
9529 WHITE ASPEN PLACE, Charlotte, NC 28269
Seasonal Swimming Pool · NC permit/State ID 2060500937
Latest result8 demerits
Last inspectedMay 21, 2026
Inspections on record14
On record sinceJun 26, 2013
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jun 26, 2013Lower is betterMay 21, 2026
Inspections & violations
May 21, 2026 8 demerits · 2 violations
Inspector comments: No Night Swimming.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed slight debris on pool floor. Clean as needed.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed slight debris present in skimmers. PIC emptied.
May 19, 2025 0 demerits · 0 violations
Inspector comments: No violations noted.
No violations were recorded for this inspection.
May 16, 2024 10 demerits · 2 violations
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
.2524(b) Lighting shall be sufficient to illuminate all parts of the pool, the water, the depth markers, signs, entrances, restrooms, safety equipment and the required deck area and walkways. Observed two lights out in both the women’s and men’s restrooms. CPO stated that he will be replacing them soon.
#22 · Premises: emergency telephone provided −6
.2530(f) Pool telephone shall be capable of directly dialing 911 or another emergency notification system. Observed emergency phone buttons not operable and unable to dial out. CDI: CPO replaced emergency phone with one that functions properly.
May 23, 2023 6 demerits · 2 violations
#20 · Premises: caution signs posted at hot water spas −4
.2532(16) Provide signage requiring a shower for each user before entering the spa and prohibiting oils, body lotion, and minerals in the water. Observed no signage requiring users to shower before entering pool. Corrected during inspection, pool operator supplied a sign advising patrons to shower before entering pool.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(m) Keep restrooms and fixtures clean and in good repair. Observed detailed cleaning needed to restroom fixtures in men’s and women’s restroom.
May 18, 2022 0 demerits · 0 violations
Inspector comments: No demerits taken.
No violations were recorded for this inspection.
May 24, 2021 6 demerits · 1 violation
Inspector comments: Night swimming has not been approved.
Lights in the bathrooms do not work. Have replaced.
Pierce Sawyer is the pool operator onsite. No Signature due to COVID 19.
Issuance of permit by this Department does not negate meeting requirements of Executive order 195 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length.
Observed damaged ring buoy with degrading rope. This was corrected and a new ring buoy with a new rope was provided.
May 15, 2020 6 demerits · 3 violations
Inspector comments: 9. GC - additional "no dive" sticker added to deck
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Replace light bulbs
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Replace light bulbs, mirrors to be of shatter-proof construction
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Add backflow preventer to deck or pump room spigot
May 17, 2019 6 demerits · 2 violations
Inspector comments: NO NIGHT SWIMMING
#18 · Premises: lifeguards present or warning signs posted −4
Lifeguard sign missing. CPO put up sign
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap for back wash
May 30, 2018 6 demerits · 3 violations
Inspector comments: NO POINTS WERE TAKEN FOR THE FOLLOWING:
#22 - Observed pool phone to not be visible from pool deck. CDI: Operator made permanent sign visible from all parts of the pool deck to indicate where emergency phone is located. .2530(a) Emergency phone shall be visible from all areas inside pool enclosure.
PDSC Information verified. No night swimming.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room. Observed hose bib inside pump room and on exterior of building next to pump room without backflow prevention device.
.2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Observed ventilation fans in pump room to not be operable.
.2533(b) Provide sufficient lighting in pump room. Observed light to not be working in pump room.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. REPEAT Observed air gap needed on back wash line in pump room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2626(m) Keep restrooms and fixtures clean and in good repair. Observed glass window broken on exterior window of women's restroom. Screen is trapping broken glass inside. Repair outside window pane to prevent glass from falling onto pool deck.
Jun 28, 2017 16 demerits · 6 violations
Inspector comments: ITS issued for #18
15. Rope length corrected to 45'
28. GC-move shower sign so its more visible upon entrance to pool
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Replace missing weir
#18 · Premises: lifeguards present or warning signs posted −4
Incorrect verbage on sign, post new sign for "Warning No Lifeguard on Duty", other warning sign posted during inspection
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Keep switch on for required continuous forced ventilation
#27 · Equipment room: filter backwash discharged through an air gap −2
2" air gap required on backwash line
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Mirror to be of shatterproof construction, add toilet paper & soap to restrooms
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Backflow preventer required
Jul 19, 2016 4 demerits · 2 violations
Inspector comments: PDSC form verfied. All information in correct.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed no air gap present at backwash. Provide.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed mirrors in both restrooms are not shatter resistant. Provide.
Jun 17, 2015 18 demerits · 5 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 1 of 4 weirs missing.
#18 · Premises: lifeguards present or warning signs posted −4
Observed 3 signs saying "No Lifeguard on Duty" . The sign on the fence, across the pool, from the clubhouse was changed to a sign which read "Warning No Lifeguard on Duty" . At least one sign must be verbatim.
#22 · Premises: emergency telephone provided −6
Observed no address or phone number posted at the emergency telephone. A sign was posted during inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed no forced ventilation or natural cross ventilation in pump/chemical room. Fan only works with the light switch and does not run continuously.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed glass mirrors in restrooms. Ventilation fan is missing from Men's restroom.Micah Abercrombie signed the report.
Jun 23, 2014 10 demerits · 4 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Maintain daily records with Total Alkalinity and cyanauric readings at least every 7 days. Observed one period more than 7 days with no alkalinity or acid readings. Corrected by instruction.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Need to supply forced ventilation or natural cross ventilation, appears celing fan vent is connected to light switch, needs to be wired to run continously.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Restrooms need shatterproof mirrors.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Hose bib in pump room needs a backflow device.
Jun 26, 2013 8 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed one skimmer basket cover was cracked.
#18 · Premises: lifeguards present or warning signs posted −4
Observed signs stating "NO LIFEGUARD ON DUTY", Sign needs to have the word "WARNING" in front of the word "NO". CPO will change out the signs with correct wording by the end of the day.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “MADISON PARK” or State ID 2060500937). Inspection type (routine vs. follow-up) is not published in the county's data.