6demerits
ASHFORD PLACE APARTMENTS
905 PINEVILLE POINT AVENUE, Charlotte, NC 28217
Seasonal Swimming Pool · NC permit/State ID 2060500938
Latest result6 demerits
Last inspectedMay 14, 2026
Inspections on record13
On record sinceJun 25, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jun 25, 2014Lower is betterMay 14, 2026
Inspections & violations
May 14, 2026 6 demerits · 2 violations
Inspector comments: Information on PDSC forms and the following permit restrictions verified during today’s inspection:
Flow meter must remain operable. Flow required at 141-160 gpm to meet turnover and flow restriction of the number of returns.
Permit issued. Not permitted for night swimming.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed 1 skimmer missing its weir.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(h) Shower(s) shall be provided. Observed inoperable outdoor shower. Repair.
May 8, 2026 36 demerits · 8 violations
Inspector comments: PDSC forms and permit restrictions verified during today’s inspection: Flow meter must remain operable. Flow required at 141-160 gpm to meet turnover and flow restriction of the number of returns.
Permit denied. Items denoted holding up permit issuance:
- .2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 6.8.
- .2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7. Observed vacuum port uncovered (located at 3 1/2 ft next to steps).
- .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed a detached, damaged and sharp edges on 3 ft depth marker. Also observed a trip hazard on decking measuring greater than 1”. Repair all areas.
- .2518(e) Provide a spare basket for pump. Extra basket for pump not provided.
***Once violations are corrected, $100 return visit fee may be paid by calling Environmental Health Department at 980-314-1620.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 6.8. Needs correction.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7. Observed vacuum port uncovered (located at 3 1/2 ft next to steps). Provide cover.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed 1 skimmer missing its weir.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed heavy debris in skimmers.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy throw rope exceeding 45” requirement. CDI - Throw rope length corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed gate that is adjacent to men’s restroom not closing/self latching. CDI - Maintenance repaired during inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed a detached, damaged and sharp edges on 3 ft depth marker. Also observed a trip hazard on decking measuring greater than 1”. Repair all areas.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(e) Provide a spare basket for pump. Extra basket for pump not available. Provide.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(a) Post a shower sign visible upon entrance to the pool. No shower signage available. Provide.
.2526(h) Shower(s) shall be provided. Observed inoperable outdoor shower. Repair.
Jul 14, 2023 10 demerits · 2 violations
Inspector comments: No night swimming.
PDSC information verified along with pipe diameters
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Vacuum port was not covered at beginning of inspection. Cover was provided by operator by end of inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gate that is adjacent to the leasing office was not closing if pushed too far open, repaired during inspection. Gate will drag across concrete if it is pushed too widely opened. Gate opens uphill into a pathway that scrapes the bottom of the leading edge.
Jun 14, 2023 12 demerits · 3 violations
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
vacuum line cover missing
pump does not match pdsc
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
missing 2 eye fitting in the returns
replace overflow face plate
#26 · Equipment room: valves and pipes identified by color codes or labels −2
label the flow direction on pump piping
Jun 16, 2022 0 demerits · 0 violations
Inspector comments: No violations at this time.
No violations were recorded for this inspection.
Jun 10, 2021 4 demerits · 1 violation
Inspector comments: EHS advised operator Marcus Grissett to consider filling in small gaps in concrete on deck to avoid trip hazards within the next year.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). Observed 4 inch gap between grading and bottom of gate at entrance. CDI - Operator installed metal screen mesh two close gap.
Jun 5, 2020 4 demerits · 1 violation
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. - Observed flow meter not operating but fixed during inspection.
May 2, 2019 6 demerits · 2 violations
Inspector comments: PDSC information verified. Main drain covers must be replaced and new PDSC form submitted by 6/24/2019.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed table and chairs within 6ft of pool edge. Corrected during inspection by moving chairs and table to proper distance.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed water on floor of pump room.
May 23, 2018 8 demerits · 2 violations
Inspector comments: No night swimming visit required. Pool hours are from 10a - 8p. No night swimming permitted.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris in all 5 skimmer baskets. CDI: cleaned on site.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter stuck. CDI: repaired during inspection.
Jun 1, 2017 14 demerits · 3 violations
Inspector comments: Pool closed due to emergency phone not working properly #22. (Immediate suspension). "Pool closed" sign posted. Gate locked. Contact Arlene Lawrence at 704-617-3068 when phone is repaired.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed cracked pool wall tile at 3 1/2 ft depth marker closest to playground. Repair.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 1 missing weir. CDI: replaced. Observed debris and frogs inside skimmer baskets. CDI: baskets cleaned.
#22 · Premises: emergency telephone provided −6
Emergency phone not working properly. 911 operator could not hear me clearly. Phone cutting in and out. (immediate suspension).
Jun 2, 2016 14 demerits · 3 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 1 out of 5 weirs missing from skimmer.
Observed debris in skimmer baskets.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed rope length greater than required 45ft. Rope cut to 45ft during inspection.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter not working properly. Repaired during inspection.
May 19, 2015 12 demerits · 4 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris floating in all skimmers. Clean skimmers.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed 2 fences not self-latching. Repair latching mechanisms. Intent to suspend issued.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed ventilation fan in chemical room not operating. REPEAT VIOLATION.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed mirrors nonshatter-resistant in women's and men's restrooms.
Jun 25, 2014 6 demerits · 2 violations
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter not operating. Repair.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed fan in chemical room not operating. Repair.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “ASHFORD PLACE APARTMENTS” or State ID 2060500938). Inspection type (routine vs. follow-up) is not published in the county's data.