‹ Back to search

4demerits

PLANTERS WALK

12215 CREEK TURN DRIVE, Charlotte, NC 28278
Seasonal Swimming Pool · NC permit/State ID 2060500940
Latest result4 demerits
Last inspectedMay 8, 2026
Inspections on record13
On record sinceJun 25, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0918 Jun 25, 2014: 6May 13, 2015: 18Apr 27, 2016: 10May 4, 2017: 6Apr 9, 2018: 6Apr 17, 2019: 0May 28, 2020: 0Apr 15, 2021: 2Jun 24, 2022: 2Apr 18, 2023: 0May 6, 2024: 0May 12, 2025: 4May 8, 2026: 4
Jun 25, 2014Lower is betterMay 8, 2026

Inspections & violations

May 8, 2026 4 demerits · 1 violation
Inspector comments: Night Swimming is not permitted. If facility wishes to obtain permit for night swimming please contact main office at 980-314-1620 Main drain covers expire: 4/14/2030 Equalizer covers expire: 4/14/2030
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). EHS observed some gaps under fence measuring at 5-6 inches. **Pool was built pre 2010 - not a permit denial item, demerit only** -4-

View this inspection on the county portal ›

May 12, 2025 4 demerits · 1 violation
Inspector comments: Nigh swimming not permitted. Contact EHS at 704-621-2294 to schedule night swimming permit visit this season.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
.2524 For Night Swimming - provide sufficient lighting so that all parts of the pool and required deck area are visible and main drains are clearly visible. Observed lights not operable during inspection. Facility previously approved for night swimming. EHS unable to verify lighting when present. Contact EHS at 704-621-2294 if facility is looking for night swimming permit. No night swimming currently permitted.

View this inspection on the county portal ›

May 6, 2024 0 demerits · 0 violations
Inspector comments: Inspection conducted with Mike Sudol.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 18, 2023 0 demerits · 0 violations

No violations were recorded for this inspection.

View this inspection on the county portal ›

Jun 24, 2022 2 demerits · 1 violation
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed mirrors not shatterproof in restrooms.

View this inspection on the county portal ›

Apr 15, 2021 2 demerits · 1 violation
Inspector comments: Covid 19 restrictions, no signature. Mike present.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed mirrors not shatterproof in restrooms.

View this inspection on the county portal ›

May 28, 2020 0 demerits · 0 violations
Inspector comments: No violations noted.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 17, 2019 0 demerits · 0 violations
Inspector comments: No violations during inspection. Will make a return visit on 4/26/19 to verify night swimming.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 9, 2018 6 demerits · 2 violations
Inspector comments: NO LIFEGUARD REQUIRED AT POOL. POOL WANTS NIGHT-SWIMMING. WILL RETURN TO VERIFY IF POOL CAN BE PERMITTED FOR NIGHT-SWIMMING.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Concrete foothold measuered at 36 inches outside of gate. FENCE WAS CONSTRUCTED BEFORE 2010. NO PERMIT ACTION.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
.2518(d) Piping and valves shall be labeled with color codes or labels. No flow directions. CDI- Relabeled with marker.

View this inspection on the county portal ›

May 4, 2017 6 demerits · 2 violations
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Light junction box on exterior of fence was less than 45 inches and thus a foothold. Pool was constructed prior to 2010. No permit action taken.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
No labels in direction of flow on pipes. CORRECTED - CPO labeled pipes.

View this inspection on the county portal ›

Apr 27, 2016 10 demerits · 3 violations
Inspector comments: POOL PERMIT CAN BE ISSUED.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some soil on pool wall tiles. ** Clean.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some deck cracks with spots that have chunks/chips of concrete. ** Repair/ patch deck where needed.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Equipment/ chemical room floor wet due to leak at wading pool pump. ** Fix.

View this inspection on the county portal ›

May 13, 2015 18 demerits · 6 violations
Inspector comments: 15 - One ring buoy of two damaged. Removed from deck. Pool lifeguarded at all times. Ring buoy must be in good repair if placed on deck.Note: Paper towel dispenser in women's is sticking. Keep in good repair. Permit will not be issued until PDSC forms submitted and approved. Currently, PDSC form on file has incorrect pump information. Permit will be posted online once forms approved. Post permit visible upon entrance to the pool. (2) Sta-Rite P4E6H-190L, (10) 6HPxxx, (2) Aquastar
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some debris on pool floor. Keep clean.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One weir sticking. Shaved down during inspection and operating properly.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some cracking/damage to deck at corners of 5 ft. Keep deck in good repair. No protrusion >1/2".
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Tubing used to run chlorine to wall machine and equipment running across floor. Provide 3 ft clear walking space around equipment.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Labeling on piping wearing off or not labeled in pump room. Clearly identify all pipes with color codes or labels.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Hose bibs in pump room with no backflow prevention. Provide backflow prevention device on all hose bibs.

View this inspection on the county portal ›

Jun 25, 2014 6 demerits · 2 violations
Inspector comments: Permit was not posted at pool today. Pool permit must be posted and visible at entry. Permit may be obtained from meckpools.charmeck.org.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter not operational. Repair flow meter.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Directional lines faded or missing on equipment lines in equipment room. Label lines per rule requirement.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “PLANTERS WALK” or State ID 2060500940). Inspection type (routine vs. follow-up) is not published in the county's data.