22demerits
SAVANNAH
13315 SAVANNAH CLUB DRIVE, Charlotte, NC 28273
Seasonal Swimming Pool · NC permit/State ID 2060500954
Latest result22 demerits
Last inspectedApr 30, 2026
Inspections on record14
On record sinceApr 25, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Apr 25, 2014Lower is betterApr 30, 2026
Inspections & violations
Apr 30, 2026 22 demerits · 5 violations
Inspector comments: No night swimming permitted.
Inspection completed with CPO Athena Millsaps.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(b) All suction fittings shall be installed in accordance with the manufacturer's instructions.
Observed PDSC form showing equalizer change on 02/16/2026. Observed 4 of 5 equalizer covers changed and one 2008 aquastar version.
CDI - Maintenance came from office and changed equalizer covers that did not match to 2017 aquastar and all equalizer covers correct and match PDCS form.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris.
Observed debris on the pool floor.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
Observed debris in skimmers.
CDI - CPO cleaned skimmers.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521(b) Ladders shall have slip-resistant tread.
Observed ladder missing slip resistant tread.
CDI - CPO replaced tread on ladder.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
Observed ring buoy rope longer than required length.
CDI - CPO shortened rope to required length.
Apr 17, 2025 6 demerits · 1 violation
Inspector comments: NO NIGHT SWIMMING.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope that was too long. Rope was cut to 36’. REPEAT.
Apr 12, 2024 10 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed slight debris in 2 skimmers. CDI - Skimmers emptied.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope that was too long. Rope was cut to 36’.
Apr 6, 2023 0 demerits · 0 violations
Inspector comments: No night swimming permitted
Pool will open from sunrise to sunset.
No COVID restrictions at this time.
120 GPM
No violations were recorded for this inspection.
Apr 14, 2022 6 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Observed skimmer with debris.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(a) Provide restrooms at all pools except for hotels, motels, condominiums and apartments where pool use is restricted to guests and residents. - No access to the bathroom during the inspection.
Apr 21, 2021 18 demerits · 5 violations
Inspector comments: PDSC verified. In field review completed.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 6.9. Corrected to 7.2 during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Horizontals on service gate and fence less than 45", at time of inspection 37". Entry gate had horizontals less than 45", over 30", but additional mesh around fob entry and over horizontal. Pool built '01. .2528(b) Horizontals shall not be located less than 45" in height.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(e) Provide a spare basket for pump. No basket on site. Provided during inspection.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
No backflow prevention device on hose bibb outside chemical room. Provide backflow preventer.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
.2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose. Did not observe a hose bibb for the restrooms.
.2526(c) Floor drains shall be provided in restrooms. No floor drains in restrooms.
Apr 16, 2020 24 demerits · 7 violations
Inspector comments: Skimmer equalizer covers expire October 2020. Replace and submit updated PDSC information for approval prior to expiration of
covers. Permit will be suspended if covers are not approved and replaced prior to expiration.
No Night Swimming.
Changed to "A" Open for Business, valid permit, with condition of staying closed to public by Executive Order-120, or other Orders,
outlined in permit.
Operator unable to sign due to COVID-19 protocol and safety precautions to not share equipment.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No records for pool at time of visit. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain
cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and
total alkalinity weekly. Operator filled out records. Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Horizontals on service gate and fence less than 45", at time of inspection 40". Entry gate had horizontals less than 45", over 30", but additional mesh around fob entry and over horizontal. Pool built '01. .2528(b) Horizontals shall not be located less than 45" in height.
#22 · Premises: emergency telephone provided −6
Emergency phone number callback faded on signage.
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Operator posted new phone with all information. Corrected.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter not working at time of inspection.
.2518(g) Keep flow meter operational. Operator adjusted and corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
No 3' clearance around piping in pump room. Pool built '01.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Water off, shower not working at time of inspection. .2526(h) Shower(s) shall be provided. Operator stated this will be turned on/prior to pool opening.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No soap or paper towels/hand drying in women's restroom. Toilet in women's restroom soiled at time of inspection. .2526(j) Provide soap and soap dispenser, no glass, at each sink.
.2526(m) Keep restrooms and fixtures clean and in good repair.
Apr 26, 2019 22 demerits · 5 violations
Inspector comments: Inspection completed with TJ Havens
Observed cracked spare pump basket. CDI new baskets provided.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8.
Observed pH at 7.0. CDI brought up to 7.2
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair.
Observed cracks on certain areas of pool deck and in need of repair before further damage.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone.
Observed phone number listed on sign different from what 911 has in system. CDI number changed.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational.
Observed flow meter that was not operational
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2626(m) Keep restrooms and fixtures clean and in good repair.
Observed toilet in womens restroom in need of cleaning.
May 10, 2018 12 demerits · 4 violations
Inspector comments: Observed old emergency phone number crossed off but still visible on tape. CDI, operator removed old number from phone.
#19 · Premises: signs prohibit glass containers or pets in pool area −4
Observed no pool signage prohibbiting pets located at pool. CDI, Required pool signage provided.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter stuck upon arrival. CDI, operator adjusted flow meter while on-site.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed light in pump room not working. Repair.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed shower not working.
Jun 28, 2017 0 demerits · 0 violations
Inspector comments: #15: Ring buoy and throw rope was not approved. buoy and rope has been replaced.
#22:Pool had been closed due to emergency phone not operating. Phone has bee corrected.
No violations were recorded for this inspection.
Jun 26, 2017 12 demerits · 2 violations
#22 · Premises: emergency telephone provided −6
Emergency phone is not operational. Pool permit immediately.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
ring buoy and throw rope was not approved. Replace prior to pool being reopened.
Mar 30, 2016 24 demerits · 7 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed debris on the pool floor. Clean.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Observed the No Diving and 3FT by the steps fading. CDI- Outlined. Ensure the writing is filled in.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed the concrete chipping and lifting around a ladder post. CDI- Removed all the chipping concrete, made area smooth, and placed the borders around the base of the ladder.
#22 · Premises: emergency telephone provided −6
-Observed no dialing instructions for the emergency phone. CDI- Wrote and placed in the box.-Observed the phone number badly faded. CDI- Rewritten.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed the light in the pump room not working. Repair.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Observed some of the pipes in the pump room unlabeled. CDI- Labeled.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed the shower not operating. Repair.*NOTE: All Pump, MD, Skimmer, Etc information has been verified.*ACCESS POOL PERMIT ONLINE AFTER 3 BUSINESS DAYS AT HTTP://MECKPOOLS.CHARMECK.ORG*Report emailed to inspectionscharlotte@gmail.com
Apr 30, 2015 18 demerits · 4 violations
Inspector comments: Observed pool deck developing cracks. Observed some pool deck developing some wear near pool ladder. Maintain in good repair.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed floating debris in skimmer baskets.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed rope around ring buoy with fraying. CDI, operator provided a new ring buoy and rope while on-site.
#22 · Premises: emergency telephone provided −6
Observed no dialing instructions at emergency pool phone. Observed incorrect telephone number posted on emergency pool phone. CDI, operator provided dialing instruction sign during inspection and posted the correct telephoen number for the emergency phone number while on-site.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed lights not working in equipment room.
Apr 25, 2014 10 demerits · 2 violations
Inspector comments: PERMIT WILL BE AVAILABLE ONLINE AT HTTP://MECKPOOLS.CHARMECK.ORG 3 BUSINESS DAYS AFTER INSEPCTION.MAINTAIN DAILY POOL CHECK PAPER WORK ONCE POOL OPENS.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring bouy rope measured at 36FT. CORRECTED TO 31FT.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter bobbit observed to be stuck.OPERATOR CORRECTED FLOW METER DURING INSPECTION.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “SAVANNAH” or State ID 2060500954). Inspection type (routine vs. follow-up) is not published in the county's data.