Apr 24, 2026 14 demerits · 4 violations
Inspector comments: Permit restrictions: Flow meter must remain operable not to exceed 280gpm due to number of returns and filter restrictions. 2 EQ
blocked
No night swimming.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs.
Observed 1 missing weir. -CDI- Weir was replaced during inspection.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
Observed large accumulation of debris in skimmer baskets. -CDI- Skimmer baskets were cleaned.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions.
Observed missing rubber bumper on one of the ladders. -CDI- CPO reattached rubber bumper.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
Observed rope for the buoy longer than 50 feet. -CDI- Rope was reduced to 50 feet.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water.
Observed standing water in the pump room.
May 2, 2025 16 demerits · 4 violations
Inspector comments: No night swimming
Conducted pool inspection with CPO Steven Edmunds
Permit restrictions: Flow meter must remain operable not to exceed 280gpm due to number of returns and filter restrictions. 2 EQ
blocked
PDSC form has been updated.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 8.3. CDI -CPO added acid to bring down pH to 7.3
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Observed debris floating in skimmers. CDI- CPO cleaned skimmers during the inspection.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(10) Diving equipment and pool slides including stairs and railings shall be kept in good working order. Observed both hand rails loose not fully secured. CDI -CPO was able to secure both hand rails.
#32 · Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean −2
Observed debris on floors in men restroom in need of cleaning.
Apr 9, 2025 24 demerits · 5 violations
Inspector comments: No night swimming
Conducted pool inspection with CPO Steven Edmunds
Permit Denied Q status
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Main drain covers do not match PDSC form. PDSC form states main drain covers needs to be AquaStar 1216XXX. Current main drain covers are R12MFXXX.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One weir not installed. .2518(k) Provide functional weirs.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed three endcap( bumper) missing on ladder and hand rails.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed address for emergency phone not transferring to 911. 911 operator stated that system was not showing address or phone number. All info on emergency phone sign posted was correct including address matching with permit. Will follow up within a few days to ensure address is transferring to 911.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Per permit flow meter must be operatable. Observed unreadable flow meter in pump room. During inspection new flow meter was installed and reading below 280GPM per permit.
Jun 13, 2024 30 demerits · 7 violations
Inspector comments: No night swimming
Conducted pool inspection with CPO Steven Edmunds
Permit restrictions: Flow meter must remain operable not to exceed 280gpm due to number of returns and filter restrictions. 2 EQ blocked.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed no pool book for pool. Observed log book for another pool. CDI: CPO marked through name of other pool and corrected name. Observed no documentation for daily main drain checks in record book. CPO created a spot in record book for daily main drain checks.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Observed debris floating in skimmers. CDI- PIC cleaned skimmers during the inspection.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed 1 endcap( bumper) missing on ladder. CDI: replaced
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. - Observed throw rope > 50ft. CDI- CPO cut rope to 50ft.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed lawn chairs less than 6ft from pool edge. CDI: chairs moved back.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed address for emergency phone not transferring to 911. 911 operator stated that system was not showing address but was showing correct phone number. All info on emergency phone sign posted was correct including address matching with permit. Per phone call w/ K.Rudisill, no permit action was taken due to state directive. Will follow up within a few days to ensure address is transferring to 911.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. Mirrors not shatterproof in restrooms.
.2526(j) Provide soap and soap dispenser, no glass, at each sink. Observed no soap in men’s restroom.
Jun 15, 2023 16 demerits · 5 violations
Inspector comments: Inspection conducted with CPO Danielle Parker.
Verified items from previous inspection have been corrected.
*Note* Sign placed at the top of the gate must remain in place to maintain > 45” between horizontals.
Pool floor and walls cracked and chipping. Maintain in good condition.
Some depth and no diving markers on pool deck cracked. Recommend replacing.
Walls in pump room damaged from leaking showers. Maintain in good condition.
Recommend providing chemical hazard placard on chemical storage room door. Currently only installed on pump room door.
Permit issued
No Night Swimming
Paper permit will be available on our website https://health.mecknc.gov/envhealth/pools in 3-5 business days for your records.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
New depth markers on pool wall missing “Feet” or “FT”. .2523(c) Depth markers shall include the word "feet" or symbol "ft". - Corrected.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy with new 55 foot throw rope. .2530(a) US Coast Guard approved ring buoy with 50 foot throw rope at least 1/4 inch in diameter. - Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Water from shower leaks in the pump room. .2533(d) Pump room floor shall be kept dry and free of standing water.
Fan not working in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Shower not functioning. .2526(h) Shower(s) shall be provided.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Lights not working in women’s restroom. .2526(m) Keep restrooms and fixtures clean and in good repair.
Jun 8, 2023 34 demerits · 9 violations
Inspector comments: Inspection conducted with CPO Danielle Parker.
Pool floor and walls cracked and chipping. Maintain in good condition.
Some depth and no diving markers cracked. Recommend replacing.
Pre-permit inspection did not pass
6)
9)
12)
15)
16)
There is a $100 re-inspection fee that must be paid prior to scheduling a re-inspection by calling our office (980-314-1620) and paying with a credit card.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
One equalizer line cover with large gap between cover and adapter plate. .2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7. - Pre-permit item.
One equalizer line plugged in the wall, but had spring loaded pop-up cover in the skimmer. Will need to be abandoned per state guidelines per PDSC form. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. - Pre-permit item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One weir not installed. .2518(k) Provide functional weirs.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
More than 25 feet between some depth markers on pool wall. .2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool. - Pre-permit item.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
One eyeball fitting missing. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. - Corrected.
Fitting missing for auto-fill. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. - Pre-permit item.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy with 32 foot throw rope. .2530(a) US Coast Guard approved ring buoy with 50 foot throw rope at least 1/4 inch in diameter. - Pre-permit item.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Magnetic latch at main gate creates a foothold. .2528(b) Horizontals shall not be located less than 45" in height. - Pre-permit item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Water from shower leaks in the pump room. .2533(d) Pump room floor shall be kept dry and free of standing water.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Shower not functioning. .2526(h) Shower(s) shall be provided.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Lights not working in women’s restroom. .2526(m) Keep restrooms and fixtures clean and in good repair.
May 13, 2022 10 demerits · 3 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
REPEAT
.2537(14) Keep pool surface and pool floor free of debris. Observed pool floor covered with debris in need of cleaning.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
REPEAT
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.. Observed several skimmer boxes full of debris in need of general cleaning.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water; Pump room floors and walls in good repair; Observed wet floor in pump room with heavy water damage to right side wall in need of repair.
May 26, 2021 22 demerits · 5 violations
Inspector comments: CPO Hannah present during the pool inspection. No signature occurred due to covid19 pandemic. Issuance of the pool permit does not negate meeting requirements of executive order 195 or subsequent orders in effect unless such orders are rescinded or suspended by another applicable order. No night swimming shall occur until another visit is made by the regulatory authority for approval. PERMIT RESTRICTION - FLOW METER MUST REMAIN OPERABLE NOT TO EXCEED 280 GPM DUE TO NUMBER OF RETURNS AND FILTER RESTRICTIONS. 2 Eq plugged.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. - Observed Cl at 0.5 ppm Cl. CDI- By the end of the inspection EHS observed pool Cl at 2 ppm.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. - Observed debris floating in pool and on pool floor. CDI- PIC started cleaning pool floor during the inspection. EHS could see bottom of pool and verify main drain covers.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Observed debris floating in skimmers. CDI- PIC cleaned skimmers during the inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. - Observed throw rope over 50ft. CDI- PIC cut rope down to 50ft.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(b) Provide sufficient lighting in pump room. - Observed light in pump room not functioning.
May 29, 2019 0 demerits · 0 violations
Inspector comments: No violations.
No violations were recorded for this inspection.
Apr 25, 2018 20 demerits · 5 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed heavy debris floating in pool.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed heavy debris floating in skimmer baskets.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed no ring bouy provided. CDI ring bouy provided rope measure to 50 ft.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed no floating indicator in flow meter.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed heavy water leak in pump room.
Observed ventilation tied to light switch in pump room. Mechanical ventilation shall be continuous and not tied to light switch or provide cross ventilation.
Jun 20, 2017 20 demerits · 6 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Clean skimmer baskets. Missing weirs(5-6) replaced in skimmers at time of inspection.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Replace damaged depth marking tile on interior of wall of pool. Missing number and FT marking placed on tile with permanent marker at time of inspection.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Protruding vacuum line extension removed from wall and capped.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Repair stuck flow meter.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Repair ventilation in chemical room. Mechanical ventilation shall be continuous and not tied to light switch or provide cross ventilation in chemical room.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Label flow of water on pool piping.
Jun 2, 2016 12 demerits · 4 violations
Inspector comments: **THROW ROPE CORRECTED TO 50FT**
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
SOME DEBRIS IN POOL
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
STEP RAILING LOOSE
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
PUMPS LEAKING; FLOW METER STUCK
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
SINKS PULLING AWAY FROM WALLS IN RESTROOMS
Jun 17, 2015 12 demerits · 4 violations
Inspector comments: Ring buoy weathered. Recommend replacing. Pool lifeguarded when open.Pool permit not observed. Print permit and post in pool area.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Missing one weir. Install functional weirs.Three returns partially blocked. Plug in place with slotted openings. Remove plugs.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Both handrails loose. Not securely anchored. CPO unable to anchor. Will replace with new style handrails.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. Repair or replace.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Pumps leaking. Fix leak. Fan not working. Fix fan.
Jun 17, 2014 18 demerits · 5 violations
Inspector comments: #11 One ladder loose. **secure.
GC #12 Missing 2 inlet fittings. **CDI.
2 inlet fittings missing parts. **1 replaced while on-site.
GC #15 Lifeguarded pool - ring buoy on-site has ~55' rope. **Rope shortened to 48' .
GC #17 Chairs @ tables (life gurad stand side of pool) 5' & 6' from pool edge. **pool over 1600sqft; maintain 8' of clear walking space.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Scum on pool wall tiles. **clean.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
4 (of*) weirs missing. **1 availabe weir installed while on-site; install the rest.
#22 · Premises: emergency telephone provided −6
Emergency phone number not posted. **CDI.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Forced air vents in equipment & chemical rooms inoperable. **repair/ replace if necessary.
Leak @ flow meter. **correct.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Circulation pipes not labeled. **CDI.