10demerits
CITISIDE POOL & CABANA
4500 EAVES LANE, Charlotte, NC 28215
Seasonal Swimming Pool · NC permit/State ID 2060500965
Latest result10 demerits
Last inspectedMay 21, 2026
Inspections on record13
On record sinceJun 25, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jun 25, 2014Lower is betterMay 21, 2026
Inspections & violations
May 21, 2026 10 demerits · 3 violations
Inspector comments: PERMIT RESTRICTION: VFD MUST REMAIN OPERABLE. AQUASTAR FLOW METER MUST REMAIN OPERABLE. FLOW REQUIRED AT LEAST 330 GPM TO MEET TURNOVER AND SHALL NOT EXCEED 500 GPM DUE TO DRAIN COVER FLOW RESTRICTION. SUCTION HAZARD.
NO NIGHT SWIMMING.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris.
Observed pool floor filled with debris.
CPO getting pool floor cleaned today.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times.
Observed one row of 6 chaise lounge chairs stored less than 6 ft from premises of pool.
Maintain chaise lounge chairs at least 6 ft from the pool.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(l) Provide toilet paper and dispensers in restrooms.
Observed no toilet paper available in women's restroom.
CPO corrected during inspection and refilled with more toilet paper.
Apr 23, 2025 8 demerits · 2 violations
Inspector comments: Permit restriction: VFD must remain operable. Flow meter must remain operable. Flow shall not exceed 500 gallons per minute due to drain cover flow restriction.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed leaf debris on pool floor
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed some furniture within 6 feet of the edge of the pool corrected on site
May 24, 2024 10 demerits · 2 violations
Inspector comments: .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Observed pool mgt Company submitted incorrect PDSC form. Where 10 skimmers had been previously plugged, have now been fitted this season with New Aquastar 6 HPXXX OR 6 HPHAXXX VGBA-2017 equalizers. Based on field calculations, these will be accepted Provisionally that a new PDSC for is submitted immediately and approved. Failure to provide and or receive approval will necessitate a return visit to suspend permit until corrected.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Observed pool mgt Company submitted incorrect PDSC form. Where 10 skimmers had been previously plugged, have now been fitted this season with New Aquastar 6 HPXXX OR 6 HPHAXXX VGBA-2017 equalizers. Based on field calculations, these will be accepted
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed slight debris on pool floor
May 30, 2023 4 demerits · 1 violation
Inspector comments: ***Main drain covers expire March of 2024
300 GPM
Pool hours are from sunrise til sunset.
No night swimming permitted.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Remove stains from pool floor through the pool.
Jun 2, 2022 10 demerits · 2 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed leaf debris in bottom of pool
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.observed degraded rope. Replaced
Apr 15, 2021 12 demerits · 3 violations
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool. Depth markers on deck and water level tiles more than 25” from edge to edge along pool perimeter. Depth marker on deck stenciled onto deck with paint during inspection to correct. *Waterlevel tiles shall be corrected by 2022 seasonal permitting*
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Observed chain link not fitted onto service gate creating large opening. Chain link fitted to fence to prevent openings.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Deck chairs <6 ft. From pool side. Chairs moved.
May 8, 2020 0 demerits · 0 violations
Inspector comments: Verified PDSC information.
No violations were recorded for this inspection.
Jun 13, 2019 10 demerits · 2 violations
Inspector comments: -PDSC information verified and correct
- Facility does not want night swimming; night swimming not permitted.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. - Observed the front gate bouncing back open. CDI (corrected during inspection) - gate was adjusted to latch.
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. - Observed on door in the clubhouse missing an alarm. CDI - alarm was added during the inspection.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall be accessible to all pool users. - Observed the emergency phone on the outside of the pool gate and not easily accessible in an emergency. CDI - phone was moved to the window inside the pool gate.
May 23, 2018 34 demerits · 7 violations
Inspector comments: Pool NOT Permitted For Night Swimming.
Permit number 0601
J. Mullis Operator
#3 · Water quality: pool water pH −6
Observed pH below 7.2 on arrival. Observed pH adjusted to 7.2 during inspection.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed debris on pool floor and walls. Pool in need of cleaning.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed floating debris in skimmers.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Observed "No Diving" marker and depth marker more than 25ft apart. Markers provided during inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed rope length at 60 feet. Corrected during inspection to 50 ft.
Observed ring buoy with torn wrap around rope. Ring buoy replaced.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck drain missing cover more than 1 inch. Pudie was added to cover hole.
#22 · Premises: emergency telephone provided −6
Observed phone number provided on emergency phone sign not correct phone number. Correct phone number provided and verified.
Jul 7, 2017 10 demerits · 2 violations
Inspector comments: PDSC form incorrect. Facility must submit updated form to William Harrison at 704 507 6824 by end of day Tuesday July 11th with correct information. Drains and equalizers verified in field.
**Intent to suspend for doors and windows. Must be fixed within 30 days. Call Christopher Sells for reinspection.
Facility not approved for night swimming.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed rope length at 53 feet. Corrected during inspection
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed club house sliding glass door and regular door opening on to pool deck, not self closing self latching or alarmed. Window not secured at 3 inches. **Intent to suspend,
Jun 27, 2016 8 demerits · 2 violations
Inspector comments: Update PSDC form Pump model Pentair eqk series EQK750
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Pentair Eq series eqk 750
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
need 3 back flow preventers
Jun 25, 2015 34 demerits · 8 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Maintain records of total alkalinity and cyanuric acid at least weekly. Observed TA/CA recorded only one time in the past month.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed discolored plaster on stairs. Observed one cracked wall tile near 5ft end.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed cross hair fittings on pool wall at return lines. Provide correct fitting.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed both throw ropes on ring buoys 53 1/2 ft. Ropes should be 50ft. Corrected during inspection- ropes cut.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gate must be self-closing and self-latching unless gate attendent and lifeguard are present. ITS issued. Observed gate not latching.
#22 · Premises: emergency telephone provided −6
Provide visible sign stating location of emergency phone. Observed phone not visible from enclosure and no sign posted. Corrected during inspection- sign posted.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed som leaking pipes in pump room. Observed flow meter not properly functioning.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Mirrors should be shatter proof.
Jun 25, 2014 8 demerits · 2 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No dates on some of the records. Provide dates on the sheets.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Pool floor has worn through to plaster at steps and several spots on main floor. Keep in good repair.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “CITISIDE POOL & CABANA” or State ID 2060500965). Inspection type (routine vs. follow-up) is not published in the county's data.