24demerits
HYDE PARK CONDOMINIUMS
10700 HILL POINT COURT, Charlotte, NC 28262
Seasonal Swimming Pool · NC permit/State ID 2060500970
Latest result24 demerits
Last inspectedApr 28, 2026
Inspections on record15
On record sinceApr 8, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Apr 8, 2014Lower is betterApr 28, 2026
Inspections & violations
Apr 28, 2026 24 demerits · 5 violations
Inspector comments: PERMIT RESTRICTION: Flow meter must remain operable. Flow required at 140 GPM to meet turnover and flow restriction of filter. If pump cannot maintain flow may require change in the future.
NOTE: Meshing on the gat does not meet code. Bubble over push button required in place.
EHS unable to determine if glass in restrooms are shatterproof.
Construction: 5/1/2002
Rope: 45’
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8.
PH below 7.2 at start of inspection. Corrected to 7.3 during inspection.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance.
Per permit restrictions, flow required at 140gpm. CPO had unit turned up while adjusting PH. After PH adjustment was complete unit was turned down and 140gpm was achieved.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions.
Ladder on backside of pool loose. Tightened during inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
Rope exceeded 45’ per permit restriction. Cut and knotted during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gaps between horizontal and ground at 6”
Gaps between verticals greater than 4” near brick columns.
Pool built prior to 2010 rule.
Jul 11, 2025 0 demerits · 0 violations
Inspector comments: Inspection completed with Mike Dignan and Danielle Parker present.
All items listed on previous visit/inspection have been corrected (gaps between gates and fencing > 1/2 inches, footholds at fencing, emergency phone operational, and automatic feeder not calibrated).
Note: observed metal wire meshing installed on gates and fencing at 1 inch by 1/2 inch. Push button on inside of pool is protected by an enclosed box at both entryways. Ensure this box enclosure remains in place at all times since wire meshing is too wide.
No violations noted during inspection.
No violations were recorded for this inspection.
Jul 9, 2025 32 demerits · 9 violations
Inspector comments: OSV to pool with Jack Mayo, Trident Pool Group, and Michael Digman, HOA, for construction final. Scope of Work - New Deck Installed. Upon arrival, pool was plastered with new waterline tile, new drain covers and deck/wall depth markers/No Diving markers.
Construction final passed. See inspection sheet.
Permit denied for the following:
Intent to Suspend issued for:
.2528 - Magnet lock installed on front of gate with horizontal. Horizontals less than 45" apart. Eliminate horizontal. Repeat item. Permit item.
>1/2" between post and gate. Maintain 1/2" or less on gate closest to restrooms. Permit item.
Push button on left side gate accessible due to openings in barrier. Maintain no greater than 1/2" within 18" of push button. Permit item.
.2530 - phone not operable - verify address, phone number and callback
.2535 - chemical feeder not calibrated - reading 7.8 at 7.2 pool reading. Calibrated feeder.
$100 return visit fee required.
Note: Deck holding water near entry to pool at restrooms. Outside of required deck space. May require repair in future if becomes a slip hazard.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No cyanuric acid. Operator refilled during the inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One skimmer missing weir. Repaired during the inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Main entry handrail loose. Keep handrails secure.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Vacuum line missing fitting. Replace vacuum line fitting. Replaced with plug during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
New barrier installed in front of old barrier in previous year. New barrier has new gates and latching mechanisms.
Magnet lock installed on front of gate with horizontal. Horizontals less than 45" apart. Eliminate horizontal. Repeat item. Permit item.
>1/2" between post and gate. Maintain 1/2" or less on gate closest to restrooms. Permit item.
Push button on left side gate accessible due to openings in barrier. Maintain no greater than 1/2" within 18" of push button. Permit item.
Old barrier around pool perimeter with <45" between horizontals and decorative features at >1.75" in width. Pool built pre-2010.
#22 · Premises: emergency telephone provided −6
Phone not operable. Phone not dialing to 911. Could not verify address, phone number or callback. Permit item.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
Feeder not calibrated. Reading 7.8. Pool pH at 7.2. Calibrate feeder. Permit item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Liquid chemicals stored in pump room. Store chemicals in approved chemical storage room.
Fan not left on in chemical storage room. Provide continuous forced draw.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
No hose bib in pump room. Original construction.
Jun 2, 2025 38 demerits · 10 violations
Inspector comments: OSV to pool with Jack Mayo, Trident Pool Group, and Michael Digman, HOA, for construction final. Scope of Work - New Deck Installed. Upon arrival, pool was plastered with new waterline tile, new drain covers and deck/wall depth markers/No Diving markers. Construction final not passed. See inspection sheet. Permit denied for the following:
.2535 - pool cloudy - pool drains shall be visible
.2535 - pool pH shall be maintained at 7.2 to 7.8
.2537 - overflow not flush to wall/sealed
.2523/.2537 - all depth markers on deck shall be slip-resistant
.2517/.2521 - >6" from wall to ladder rung; >10 ft. between handrails at step entry (both require electrical permits)
.2528 - Magnet latch provides horizontal; push button sensor accessible; maintain 1/2" between post and gate
.2522/.2537 - fill line provides trip hazard
.2535 - chlorinator not calibrated
Once items above corrected, contact Katie for a return inspection.
Note: Tablets stored outside of container in pump room. Store in labeled containers.
#1 · Water quality: water clear enough to clearly see bottom of pool and pool drain −6
Pool cloudy. Drains not visible. Could not verify VGB. Ensure PDSC form matches what is in the field. Drains shall be clearly visible. Permit item.
#3 · Water quality: pool water pH −6
Pool pH at 6.8. Maintain at 7.2 to 7.8. Permit item.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Overflow not flush to pool wall. Part of renovation. Appears has settled and "popped out". Not sealed around it. Repair overflow so flush to wall. Permit item.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
New deck tile installed. Multiple depth markers not slip resistant. Deck tile shall be slip resistant with 6x6 inch tile. Permit item.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
New decking installed. Ladder rungs 7" to 9" from wall. Ladder rungs shall be 3" to 6" from wall to rung. Permit Item.
New deck installed - pool steps >20 ft. wide. Step handrails >10 ft. apart. Handrails shall be 10 ft. apart or less.
Permit items above.
For all above items, electrical permit is required.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
New barrier installed in front of old barrier in previous year. New barrier has new gates and latching mechanisms.
Magnet lock installed on front of gate with horizontal. Horizontals less than 45" apart. Eliminate horizontal. Permit item.
>1/2" between post and gate. Maintain 1/2" or less. Permit item.
Push button on left side entry accessible. Maintain no openings >1/2" within 18" of locking mechanism. Permit Item.
Other items noted on old barrier. <45" between horizontals and openings greater than 1.75". Horizontals shall be 45" apart or greater with no openings >1.75".
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Fill line on deck located >6" from handrail. Fill line moved during deck repair. Fill line shall be within 6" of handrail. Fill line can be plumbed in pump room as direct fill if facility chooses. Permit item.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
Pool pH at 6.8. Feeder reading 7.4. Calibrate feeder. Permit item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Liquid chemicals not stored in chemical storage room. Store chemicals in the approved chemical storage room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water in restrooms >113 F. Maintain at 110 F or below.
Toilet in men's restroom soiled. Keep fixtures clean.
May 3, 2024 6 demerits · 1 violation
Inspector comments: Paul is open for 2024 season. no Nightswimming permit. Phone originally did not ring when called. Pool Operator reset modem. and corrected the issue phone now rings
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable.
Apr 5, 2023 6 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed floating debris in pool an debris in skimmer basket.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. Observed mirrors in restrooms not shatterproof.
Apr 14, 2022 18 demerits · 6 violations
Inspector comments: 22. a new sign is needed - labeling is starting to peel off
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Vacuum port > 2" from pool wall, corrected during inspection
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
section of fence where space under fence exceeds 4"
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
flow meter fixed during inspection
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
mirrors to be of shatter-proof construction; shower not in working order and handle is not accessible
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
backflow preventer needed on hose bib on deck
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
label fan switch so it stays on, continuous forced ventilation required; store chemicals off the floor
Apr 29, 2021 14 demerits · 3 violations
Inspector comments: Dexter on site today. No night swimming.
17. .2537 (2) observed chipping and fractures in concrete pool deck. monitor for offsets.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length.
observed rope length > 45'
CDI
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Provide no openings in fence and/or gate greater than 4"x4".
observed openings > 4" between vertical fence members.
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010).
observed areas of fence with openings > 4" under fence.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(e) Provide a spare basket for pump.
no extra basket on site. CDI
May 29, 2020 8 demerits · 2 violations
Inspector comments: 22. Dialing instructions added to sign - recommend new sign with phone number, address added to dialing instructions
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy rope corrected to 45' during inspection
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Shower needs more accessible handle, mirrors to be of shatterproof construction
Apr 8, 2019 16 demerits · 4 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
2521. Observed loose ladder rail with a separated ladder step. CDI- Ladder step was repaired and railing tightened.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Buoy float was damaged. CDI- Buoy float replaced during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed side entrance gate not self closing. CDI- Gate repaired during inspection to self close. .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. Club house windows open more than 4". CDI- PO corrected windows to open no more than 4".
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed areas under fence by parking lot side of pool with gaps 7". Needs correcting. - Pre 2010 pool - Non permit item. .2528(a) Provide no openings in fence and/or gate greater than 4"x4". Observed several areas of fence next to brick columns with gaps larger than 4", 5-6" gaps observed. Needs correcting - Pre 2010 pool - Non permit item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter was stuck, not operating, flow meter corrected to operate.
GENERAL COMMENT: All permit items corrected during inspection. Permit issued
Observed one 4FT depth marker on pool wall faded, needs correcting/ replacing by next season.
Apr 4, 2018 6 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Weirs missing on skimmers. CDI- Weirs were replaced.
Skimmers with debris in and under baskets. CDI- Skimmers were cleaned.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Missing one bump on the ladder. Need to be replaced.
Apr 6, 2017 10 demerits · 2 violations
Inspector comments: • 'Pool has passed pre-inspection. Noted violations were corrected. Fence has gaps at some points that are greater than 4". Fence was constructed 5/1/2002.
Post permit in public view. Permit should be available in 1-3 business days.
#3 · Water quality: pool water pH −6
Observed pH 7.0. pH 7.2--7.8 is the safe range. pH corrected to 7.3. -C.D.I.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed vacuum line port uncapped. Cap was placed into the port. -C.D.I.
Apr 28, 2016 22 demerits · 6 violations
Inspector comments: 16) Observed opening under the fence filled with stone.24) Timer switch connected to the same breaker box as the pool pump breakers. Ensure that pump runs 24 hours a day when poolis open.Permit will be issued online at Meckpools.charmeck.org within 1-3 business days. Print copy of permit to post in pool area.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
New main drain covers installed, Aquastar 9MFxxx. Permit will not be issued until updated PDSC form has been submitted and approved. Updated form submitted and approved.Vacuum port missing the plug. Provide plug for vacuum port. Corrected by operator.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Weir floating in the skimmer. Corrected.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder loose. Maintain secure and in good condition.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Openings > 4" through the fence. Provide fence with no openings > 4".
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Chemicals and general storage in the pump room. Chemical storage room used for general storage. Store chemicals in thechemical storage room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Mirrors are not shatterproof nor are they attached to the wall with mastic or safety backing. Provide shatterproof mirrors inrestrooms.No soap in women's restroom. Provide soap.
May 5, 2015 2 demerits · 1 violation
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed soap not present at both men's and women's restroom. Provide soap.
Apr 8, 2014 10 demerits · 2 violations
#22 · Premises: emergency telephone provided −6
Legible sign must be posted with the telephone number of the emergency phone. Observed faded phone number. Number was re-posted.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Maintain gates to be self latching. Observed on gate lock taped. Repaired to allow for self latching.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “HYDE PARK CONDOMINIUMS” or State ID 2060500970). Inspection type (routine vs. follow-up) is not published in the county's data.