‹ Back to search

20demerits

MILL CREEK MASTER

8725 APPLEDALE DR, Charlotte, NC 28262
Seasonal Swimming Pool · NC permit/State ID 2060500978
Latest result20 demerits
Last inspectedMay 21, 2026
Inspections on record13
On record sinceJun 5, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01224 Jun 5, 2014: 10Jun 17, 2015: 4May 18, 2016: 8May 4, 2017: 10May 16, 2018: 6Apr 24, 2019: 4May 7, 2020: 12May 20, 2021: 4May 12, 2022: 24May 19, 2023: 4May 9, 2024: 6Apr 15, 2025: 6May 21, 2026: 20
Jun 5, 2014Lower is betterMay 21, 2026

Inspections & violations

May 21, 2026 20 demerits · 4 violations
Inspector comments: Equalizers were removed and plugged during inspection in accordance with PDSC form. No Night Swimming.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7. Observed 11 equalizer lines with equalizers still attached despite no equalizers being listed on PDSC form. Equalizers are to be permanently plugged per state recommendations. CDI - PIC removed equalizers and installed plugs during inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed slight debris present on skimmers. Skimmers emptied during inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed 60 ft ropes. CDI - Ropes cut to 50 ft. .2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy. Observed one ring buoy in bad repair. CDI - Ring buoy replaced.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Horizontals shall not be located less than 45" in height. Observed 36” between horizontals. Pool and fence built in 2002.

View this inspection on the county portal ›

Apr 15, 2025 6 demerits · 1 violation
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed safety rope longer than 50FT. CDI PO cut rope to adjust to 50 ft.

View this inspection on the county portal ›

May 9, 2024 6 demerits · 2 violations
Inspector comments: Walked with Rob Gariepy
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris in skimmer
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed water on pump room floor

View this inspection on the county portal ›

May 19, 2023 4 demerits · 1 violation
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter stuck . CdI PIC adjusted flow meter to make operational.

View this inspection on the county portal ›

May 12, 2022 24 demerits · 7 violations
#3 · Water quality: pool water pH −6
pH corrected to 7.2 during inspection
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
keep baskets free of debris
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
handrail tightened during inspection
#18 · Premises: lifeguards present or warning signs posted −4
No Lifeguard sign posted during inspection
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
flow meter repaired during inspection
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
natural cross or continuous forced ventilation required, light bulbs need to be replaced
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
mirrors to be of shatterproof construction

View this inspection on the county portal ›

May 20, 2021 4 demerits · 1 violation
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. - Observed debris in pool.

View this inspection on the county portal ›

May 7, 2020 12 demerits · 4 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
keep pool floor free of debris
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
weir is stuck, replaced during inspection
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
natural cross or continuous forced ventilation required
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
provide toilet paper in restrooms

View this inspection on the county portal ›

Apr 24, 2019 4 demerits · 1 violation
Inspector comments: CPO Stephen Prevatte present during inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing or damaged skimmer basket. Observed one skimmer basket with broken side. Basket replaced during inspection.

View this inspection on the county portal ›

May 16, 2018 6 demerits · 1 violation
Inspector comments: Allie Neal was present during the inspection. **Main Drain and Equilizer covers expire 10/18**
#22 · Premises: emergency telephone provided −6
.2530(a) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed address on emergency phone sign was faded and illegible. CDI- address was re-written/darkened during inspection.

View this inspection on the county portal ›

May 4, 2017 10 demerits · 2 violations
Inspector comments: Pool has passed pre-inspection as all violations noted were corrected during the inspection. The correction of the missing EQ cover requires that a new PDSC form be filled out and submitted as the pool now has 10 instead of 11 operable skimmer EQ lines. The permit will be issued when MCHD has received and approved the new PDSC form. When the permit is issued, post it in public view from the pool deck.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Observed 1 skimmer EQ line missing the cover. EQ line was plugged. -CDI
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 1 weir missing from skimmer. Weir was replaced. -CDI

View this inspection on the county portal ›

May 18, 2016 8 demerits · 3 violations
Inspector comments: 3) Observed good water chemistry. 6) Observed new Aquastar 6HPxxx installed. 29) Observed lighting now functioning in chemical storage room.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed broken tile on pool deck by steps. Clean up sharp objects.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Some piping not labled. Corrected by operator.
#27 · Equipment room: filter backwash discharged through an air gap −2
Provide air gap for backwash.

View this inspection on the county portal ›

Jun 17, 2015 4 demerits · 1 violation
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
Observed chlorine pucks sitting underneath skimmer baskets at 2 separate locations. Per pool operator chlorine automatic feeder is working properly and pucks were removed immediately. If seen again a 30 day INTENT TO SUSPEND will be issued. General Comment #15: New rope was placed on ring buoy. Previous rope was at correct length, but as precaution old rope was switched out.

View this inspection on the county portal ›

Jun 5, 2014 10 demerits · 3 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Replace the missing weir near the 5 foot side of the pool.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed one broken step on both ladders.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Repair the broken tile near the handrail.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “MILL CREEK MASTER” or State ID 2060500978). Inspection type (routine vs. follow-up) is not published in the county's data.