22demerits

AVONLEA

4835 SUNSET RIDGE CT, Charlotte, NC 28269
Seasonal Swimming Pool · NC permit/State ID 2060500980
Latest result22 demerits
Last inspectedMay 22, 2026
Inspections on record15
On record sinceJul 15, 2013

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01122 Jul 15, 2013: 20May 7, 2014: 10May 13, 2015: 6May 3, 2016: 18May 2, 2017: 4Apr 27, 2018: 6Apr 24, 2019: 10May 19, 2020: 4Apr 19, 2021: 8Apr 18, 2022: 6Apr 13, 2023: 4Apr 9, 2024: 4May 13, 2025: 8May 13, 2025: 4May 22, 2026: 22
Jul 15, 2013Lower is betterMay 22, 2026

Inspections & violations

May 22, 2026 22 demerits · 5 violations
Inspector comments: Night swimming is not permitted No permit restrictions
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine at 0ppm upon arrival. -CDI- Chlorine was able to reach 3ppm by the end of the inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed missing weir. -CDI- Weir was replaced.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Observed 2 loose ladders. -CDI- Ladders were tightened during inspection.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed VCGB able to be opened without a tool. -CDI- New fitting was installed during inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed buoy rope greater than 39 feet. -CDI- Rope was adjusted to 39 feet.

View this inspection on the county portal ›

May 13, 2025 4 demerits · 1 violation
Inspector comments: Auto switch on feeder has been removed. Auto chlorinator feeder has been installed. EHS advised PO to keep watch on the recently filled in offsets within 6 ft of the pool deck. No violations observed today. Not approved for night swimming.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed some areas of fence with greater than 4 inches underneath. CDI PO is raking straw to fill in these areas. Rain keeps stopping and starting that is prolonging the process.

View this inspection on the county portal ›

May 13, 2025 8 demerits · 2 violations
Inspector comments: EHS instructed the PO to call when deck offsets are repaired. Permit denied
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed some areas with greater than 4 inches under the fence.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. EHS observed multiple trip hazards around the pool that are greater than 1/2 inches offsets.

View this inspection on the county portal ›

Apr 9, 2024 4 demerits · 1 violation
Inspector comments: .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope length longer than 39FT. CDI- Rope cut to 39FT.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed 1 weir missing in skimmer. Replace.

View this inspection on the county portal ›

Apr 13, 2023 4 demerits · 1 violation
Inspector comments: Permit issued. No night swimming requested.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528 (a)(2) Footholds shall not be directly outside fencing. Observed one electrical box that is a foothold at the back side of pool. Cover with a sloped attachment or other means of preventing foothold.

View this inspection on the county portal ›

Apr 18, 2022 6 demerits · 2 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed pool floor covered in debris in need of cleaning.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed pump room having water accumulating due to small leak from pipe fittings in need of repair.

View this inspection on the county portal ›

Apr 19, 2021 8 demerits · 2 violations
Inspector comments: CPO dexter feaster was present during the pool inspection. No signature occurred due to covid19 pandemic. Issuance of the pool permit does not negate meeting requirements of executive order 195 or subsequent orders in effect unless such orders are rescinded or suspended by another applicable order. No night swimming shall occur until another visit is made by the regulatory authority for approval.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. - Observed some debris on pool surface and floor. EHS was able to see floor bottom and verify main drains. CDI- CPO cleaned pool during the inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Observed some floating debris in skimmers. CDI- CPO cleaned skimmers during the inspection.

View this inspection on the county portal ›

May 19, 2020 4 demerits · 1 violation
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Fill in crack on the pool deck going into the pool.

View this inspection on the county portal ›

Apr 24, 2019 10 demerits · 3 violations
Inspector comments: CPO Dexter Feaster present during inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(b) Provide required amount of clear walking space around the pool at all times. Observed pool chairs 4 1/2 feet from edge of pool at one end. Chairs moved back to > 6 feet from edge.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flowmeter present but not operational. Repaired during inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Observed vent fan not working in the pump room.

View this inspection on the county portal ›

Apr 27, 2018 6 demerits · 2 violations
Inspector comments: Steve Prevatte was present during the inspection. ***Equalizer covers and main drain covers expire October 2018. Once covers have been replaced, a new PDSC form must be submitted NO POINTS ISSUED: #2. Observed the chloring concentration was very high. Recommend keeping chlorine concentration above 1ppm, but less than 10ppm. .
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed a missing inlet fitting on the pool wall. CDI- the fiting was installed during the inspection. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed the vent fan was not working in the chemical storage room. .2533(3) Provide continuous forced ventilation or cross ventilation in pump room.

View this inspection on the county portal ›

May 2, 2017 4 demerits · 2 violations
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed ventilation fan not working in chemical room. Supply working fan unit directly wired or supply natural cross ventilation.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Need backflow prevention device on all hose bibs, no backflow device on hose bib next to women's restroom. (Corrected) PO placed backflow device on hose bib. GENERAL COMMENT: Permit to be issued.

View this inspection on the county portal ›

May 3, 2016 18 demerits · 4 violations
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
PDSC form submitted does not match what was observed in the field. Main drains listed as Aquastar P12101, observed R1216. Also 2 pumps are listed on PDSC form but there is only one pump. Corrected PDSC form must be received before permit can be issued.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed 2 ft area of pool wall above tile that is degrading, needs repair soon.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Buoy rope was much longer than required 39 ft. PO cut rope to proper length.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Baseboard in men's restroom coming off wall, needs repair. Restrooms need some general cleaning.GENERAL COMMENT: PERMIT WILL BE ON HOLD UNTIL A CORRECTED PDSC FROM IS SUBMITTED

View this inspection on the county portal ›

May 13, 2015 6 demerits · 2 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed a small cracked tile on the 3 1/2 foot end.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed one loose ladder handle. TIghtened while onsite.

View this inspection on the county portal ›

May 7, 2014 10 demerits · 2 violations
Inspector comments: Deck outlet needs protective cover, water fountain needs repair Report received by Josh Moritz.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Buoy rope length corrected to 39 ft during inspection
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
1 pool light is not working

View this inspection on the county portal ›

Jul 15, 2013 20 demerits · 4 violations
Inspector comments: 5. GC- Daily records showing same readings over and over. Be sure to accurately record daily records.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
1 of 4 weirs missing, needs replacing.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy rope not maintained at 39 ft, observed 55 ft. Corrected to 39 ft.
#22 · Premises: emergency telephone provided −6
Need dialing instructions posted on emergency phone. Corrected on site.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck, not operating, needs repair.

View this inspection on the county portal ›