0demerits
MACAULAY
16023 HALLATON DR, Huntersville, NC 28078
Seasonal Swimming Pool · NC permit/State ID 2060500981
Latest result0 demerits
Last inspectedMay 7, 2026
Inspections on record14
On record sinceMay 7, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
May 7, 2014Lower is betterMay 7, 2026
Inspections & violations
May 7, 2026 0 demerits · 0 violations
Inspector comments: NO VIOLATIONS DURING INSPECTION
Permit Restriction: Flow meter must remain operable. Flow shall not exceed 500 gpm due to drain Cover Flow restriction. Suction Hazard. Approved For night swimming 5/7/2025
No violations were recorded for this inspection.
May 7, 2025 10 demerits · 2 violations
Inspector comments: PERMIT ISSUED.
Bonding wire and grounding wire on pump mentioned in last inspection has been secured and has had an electrical inspection. Auto chlorine feeder observed to stop flowing when power is off to pump.
POOL IS PERMITTED FOR NIGHT SWIMMING AS OF 05/07/2025. New pool sketch of lights recorded. There are 5 underwater lights and 7 lights surrounding the pool deck. Lighting is sufficient for night swimming with this amount of lighting. All lights were operating properly.
Filtration flow rate observed measured 300 GPM.
Permit Restrictions:
Flow meter must remain operable. Flow shall not exceed 500 GPM due to drain Cover Flow restriction.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pool pH measuring 7.0
CDI: CPO raised pH to measure 7.2
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed light debris accumulating on pool floor. Keep clean.
Apr 14, 2025 20 demerits · 5 violations
Inspector comments: Permit denied due to:
-Pump not grounded properly
-water murky and unable to visibly see main drains
- automatic chlorine feeder not able to turn off when pump it turned off.
PERMIT DENIED.
FLOW METER READING: 320
Below are the current comments and permit restrictions for the pool/spa referenced above:
Permit Restriction: Flow meter must remain operable. Flow shall not exceed 500 gpm due to drain cover flow
restriction. NIGHT SWIMMING WILL NEED TO BE APPROVED AFTER A NIGHT VISIT TO CONFIRM LIGHTING IS SUFFICIENT.
#1 · Water quality: water clear enough to clearly see bottom of pool and pool drain −6
.2535(2) Main drains must be clearly visible from the pool deck. Observed pool water murky and main drains not clearly visible. Permit denial.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed moderate debris in bottom of pool.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
.2535(6) Automatic chlorine and bromine feeder pumps shall be automatically prevented from operating when the circulation pump is not in operation. Observed automatic chlorine feeder unable to stop operation when circulation pump was turned off. CPO stated that he will have an electrician address this issue before next inspection. Permit denial.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(h) Provide approved pump in good repair. Observed pump not properly grounded. Grounding wire was not attached to bonding wire creating an electrical hazard. CPO was instructed to have an electrician repair and address this issue before next inspection. Permit Denial.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(a) Post a shower sign visible upon entrance to the pool. Observed no “shower sign” present on pool deck. CDI: CPO installed a shower sign.
May 10, 2024 6 demerits · 2 violations
Inspector comments: Walked with John Rhodes. Per field book instructions.. Both flow meters cannot exceed 500 gpa. Both flow meters were 360 total and operable.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed pool with debris
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Observed white end caps missing from pool ladder.
Apr 17, 2023 8 demerits · 2 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
small amount of debris in bottom of pool. CDI
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Small amount of build up in skimmers. Corrected during inspection (CDI)
May 18, 2022 6 demerits · 2 violations
Inspector comments: Pool is lifeguarded. Pool shall have an attendant at entrance per HOA and operator. No night swimming is permitted until pool has passed a night time pool lighting inspection. The new chemical storage room being constructed must be kept inaccessible to the public until approved.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Two weirs missing. Replace.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Sodium bicarbonate bags being stored on floor. Keep chemicals that are not protected by plastic off of floor.
Apr 7, 2021 4 demerits · 2 violations
Inspector comments: Pool will have night swimming for swim meets. Inspector will have to conduct night swimming visit. Night swimming is prohibited at this time until inspector can verify sufficient lighting. Will follow-up at a later date.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed one of the screws loose and protruding out on ladder in front of slide. Screw tightened and fixed during inspection.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. Mirrors not shatterproof in restrooms.
.2526(i) Water in restrooms shall not exceed 110 F. Observed water > 110F in both men and women’s restroom.
Apr 15, 2020 10 demerits · 3 violations
Inspector comments: GC - guarded pool - rescue tubes on site will be replaced - new ones have been ordered
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Broken eye ball fitting, replaced during inspection
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Holes in deck plugged during inspection, two small spots where hydraulic cement is needed on deck
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Mirrors to be of shatterproof construction
May 9, 2019 20 demerits · 5 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder at 3FT depth of pool is missing cap on one side.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Chairs observed too close to pool edge and ladder. Maintain 6' of clearance from pool edge and 5' from ladder. Corrected during inspection.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter is stuck. Repair or replace.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Fence is >2" from surface in spots but less than 4".
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
One equalizer line was not plugged on pool wall. Corrected during inspection. PDSC form is incorrect. Submit updated PDSC form with current equalizer information. PDSC has been corrected.
Apr 26, 2018 10 demerits · 3 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537 Pool foors kept clean; Observed pool floor in need of cleaning.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518, .2537 Skimmer systems kept clean and in good repair; Observed float valves in place but broken into pieces.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533, .2534, .2537 Keep pump room dry; Observed pump room wet with damage to back wall; observed water migrating into chemical / guard room. Observed chemicals stored in guard room with no ventilation.
Apr 27, 2017 20 demerits · 5 violations
Inspector comments: Permit will be issued at Meckpools.Charmeck.org in 1-3 business days. Print a copy of the permit to post in the pool area.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One skimmer missing a weir. Corrected by operator.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
One return missing an eyeball fitting. Corrected by operator.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
One throw rope 51.5 feet long. Corrected to 50 feet.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some deck chairs too close to pool. Maintain at least 8 feet clear walkway. Corrected by operator.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water > 110F. Maintain at 110F or less.
Some of the stalls in the men's and one of the stalls in the women's restroom without toilet paper. Provide toilet paper on a holder.
May 4, 2016 16 demerits · 5 violations
Inspector comments: Main drains located in middle of pool and inaccessible to EHS during inspection. Unable to determine if all screws present and properly secured.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed loose handrails on ladders. Repair.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed throw rope on one ring buoy of two total exceeding 50FT. CDI-rope shortened to 50FT
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed openings in vertical bars of fence >4".
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Fan not operating in pump/chemical room.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Observed hose bibb by edge of fence without a backflow preventor.
May 15, 2015 2 demerits · 1 violation
Inspector comments: Pool permit not valid until available onlinePermit inspection passed.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed hot water in bathroom at 113.Keep hot water tempered below 110.
May 7, 2014 14 demerits · 4 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed floating debirs in surface skimmers.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed openings in pool fence > 4".
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed stuck flow meter. CDI
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed water leak on pipes in pump room.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “MACAULAY” or State ID 2060500981). Inspection type (routine vs. follow-up) is not published in the county's data.