20demerits
HEATHERSTONE I
9015 MEADOW VISTA RD, Charlotte, NC 28213
Seasonal Swimming Pool · NC permit/State ID 2060500982
Latest result20 demerits
Last inspectedApr 16, 2025
Inspections on record11
On record sinceJul 8, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jul 8, 2014Lower is betterApr 16, 2025
Inspections & violations
Apr 16, 2025 20 demerits · 4 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed pool floor, walls, outside area in need of cleaning.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(d) No Diving markers shall be provided in all areas of the pool less than five feet deep. OBSERVED one of the no diving signs beginning to fade. The rest of the no diving signs were pretty visible.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Observed rope length at 60”. CDI. PIC corrected to 38” as required.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed phone signs with letters fading off. CDI. PIC replaced.
May 24, 2024 6 demerits · 1 violation
Inspector comments: CPO ERIC SPRINKLE PRESENT AT THE TIME OF THE INSPECTION.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8.
OBSERVED PH AT 7.0
CPO CORRECTED PH TO 7.2 BEFORE END OF INSPECTION.
Jun 2, 2023 12 demerits · 3 violations
Inspector comments: NOTE: Previous EHS noted that fence may need reconstructing in 2023. No reconstruction needed at the time. Fence is still in tact and functional.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH of water at 6.8. CDI- pH raised to 7.6.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed pool floor in need of cleaning.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. Observed chemicals and equipment too close to piping, valves and controls.
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed standing water in the pump room.
Jun 30, 2022 20 demerits · 6 violations
Inspector comments: Note: Several areas of damaged vinyl fencing around exterior perimeter of pool which appears to be from lawn equipment. Damage at this time does not impact integrity of fence and no missing pieces of fencing observed during visit today. Fencing may need remediation prior to permitting in 2023.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed missing rope on ring buoy. Operator replaced during inspection. Verified to be 38’ in length.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering.
.2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering.
.2530(c) All pool signage shall be visible upon entrance to the pool and permanently affixed.
.2530(c) Provide "Adults should not swim alone." in 1" lettering.
Missing rules signage and lifeguard signage. Operator replaced and affixed during inspection.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter not operating at beginning of inspection. Operator repaired during inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Observed no natural or forced ventilation in pump room.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(a) Post a shower sign visible upon entrance to the pool. No shower sign posted. Replaced during inspection.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(m) Keep restrooms and fixtures clean and in good repair.
Observed cleaning needed to the restrooms.
.2526(j) Provide soap and soap dispenser, no glass, at each sink.
.2526(l) Provide toilet paper and dispensers in restrooms.
Observed no soap, paper towels, or toilet paper provided in restrooms.
May 27, 2021 2 demerits · 1 violation
Inspector comments: Night swimming has not been approved.
Pierce Sawyer was the pool operator onsite during the inspection. No Signature provided due to COVID.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(m) Keep restrooms and fixtures clean and in good repair.
Observed cleaning needed to the restrooms. Have cleaned.
Apr 23, 2019 10 demerits · 3 violations
Inspector comments: PDSC form verified.
There are 2 footholds outside of the fence -this pool was built in 2009.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Observed Cl at 0ppm. Chlorinator valve had malfunctioned. Valve repaired during inspection and Cl was at 1.0ppm before inspection ended.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed some water on the pump room floor. Appears there may be a small leak in the PVC piping.
.2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. None available.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2626(j) Provide soap and soap dispenser, no glass, at each sink. No soap was available.
.2626(m) Keep restrooms and fixtures clean and in good repair. Restrooms are in need of cleaning.
May 14, 2018 10 demerits · 3 violations
Inspector comments: night swimming is prohibited at this pool.
observed small fractures in pool deck < 1/2"
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching.
South facing gate disabled by CPO. Brackets installed and latch mechanism removed.
CDI
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational.
flow meter stuck.
CDI
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2626(m) Keep restrooms and fixtures clean and in good repair.
restrooms dirty.
mirrors are not shatterproof.
Apr 26, 2017 0 demerits · 0 violations
No violations were recorded for this inspection.
Jun 28, 2016 2 demerits · 1 violation
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
Provide a hosebib with a backflow prevention device. Observed hose bibs missing backflow preventers.
Jun 15, 2015 0 demerits · 0 violations
No violations were recorded for this inspection.
Jul 8, 2014 14 demerits · 5 violations
Inspector comments: Several wasp nests in pump room and above emergency phone. ksg
Report received by Scott Vincent
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
Pool lights not working - replace bulbs
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Pressure guage is not working - replace
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Forced ventilation not working - should be fixed, forced or natural cross ventilation required.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Install back flow preventers on deck hose bibs
#32 · Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean −2
Floors should be slip-resistent
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “HEATHERSTONE I” or State ID 2060500982). Inspection type (routine vs. follow-up) is not published in the county's data.