MAA GATEWAY #2

120 N CEDAR ST, Charlotte, NC 28202
Seasonal Swimming Pool · NC permit/State ID 2060500984
Latest result4 demerits
Last inspectedApr 14, 2026
Inspections on record13
On record sinceMay 1, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0816 May 1, 2014: 8Apr 27, 2015: 10May 6, 2016: 4Apr 28, 2017: 16May 21, 2018: 16May 10, 2019: 0Apr 29, 2020: 4Apr 20, 2021: 16Jun 17, 2022: 14Apr 26, 2023: 8Apr 24, 2024: 6Apr 11, 2025: 16Apr 14, 2026: 4
May 1, 2014Lower is betterApr 14, 2026

Inspections & violations

Apr 14, 2026 4 demerits · 1 violation
Inspector comments: Permit restrictions: Flow meter must remain operable with max flow at 95 +/- 10% due to filter size restriction. Night swimming not allowed.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Observed debris in baskets. Cleaned.

View this inspection on the county portal ›

Apr 11, 2025 16 demerits · 4 violations
Inspector comments: All ground level windows locked and prevented from opening except one in which tenant removed locks and had window open 8 inches with a mesh screen. CPO stated tenant adjusted windows on their own. Address with tenant and inform per Law windows cannot be opened more than 4 inches. NIGHT SWIMMING NOT PERMITTED, FLOW METER MUST REMAIN OPERABLE WITH MAX FLOR AT 95 GPM +/- 10 % DUE TO SIZE RESTRCITION. EQ LINES PLUGGED/PLASTERED ON WALL. 5/21/2018 DRAIN COVER INSTALLED DOES NOT WORK WITH SUMP -2022.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. PH recorded at 6.8. CDI - Soda ash added to increased to 7.3
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Skimmers had debris inside. CDI - Cleaned.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Chairs obstructing 6 feet of clearance. CDI - Chairs mov.ed
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Pump room had standing water on floor. Clean and keep room dry.

View this inspection on the county portal ›

Apr 24, 2024 6 demerits · 1 violation
Inspector comments: CPO, Von Cassidy present during the inspection Verified main drains and pump. Night swimming prohibited. Permit issued.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy rope was 2 feet too short. CDI - CPO provided a longer rope with the correct length of 24’

View this inspection on the county portal ›

Apr 26, 2023 8 demerits · 3 violations
Inspector comments: Phil Stalnaker present during the inspection. PDSC information and permit restrictions verified. All non-compliant items corrected during inspection. Not permitted for night swimming. Permit issued.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Double doors with left door not latching. Corrected during the inspection. Back gate and front doors verified with battery back-up. Door from billiard room (new construction) verified to self-close, self-latch. Fob entry. Verified battery back-up. -4-
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. Observed bag of NA Bicarbonate stored on steps inside pump room. CPO corrected by removing off floor. Keep stored separate, off floor or in waterproof containers. .2533(d) Pump room floor shall be kept dry and free of standing water. Pump room floor wet. Keep dry. -2-
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
REPEAT: Check valve not ASSE1013. Original construction. If ever replaced, install ASSE 1013 check valve. -2-

View this inspection on the county portal ›

Jun 17, 2022 14 demerits · 5 violations
Inspector comments: Phil Stalnaker present during the inspection. Pool restrooms under renovation. Temporarily approved porta-john and sink located outside of the pool barrier in the walkway. Porta-john must remain clean for permit to be maintained. Billiard area/restrooms inaccessible to public from the pool. Door installed and self-closes, self-latches. Construction area must remain inaccessible to the public. Permanent windows installed that will not open. Once construction is complete, contact Katie Rudisill at 704-309-5494 to schedule a return inspection to final out renovation construction. Ensure restrooms have the following: 1) Floor shall be slip-resistant and sloped to drain. 2) Mirrors shall be shatterproof. No glass fixtures. 3) Provide hose bib with back flow prevention device. Pentair IntellifloXF VSF 022056 pump with (2) Lawson MLd-FG-1212 drain covers. EQ lines plastered on pool wall and plugged in skimmer. Permit issued for no night swimming. Sticker issued while onsite. The State permit should be available online by end of business today.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Double doors with left door not latching. Corrected during the inspection. Back gate and front doors verified with battery back-up. Door from billiard room (new construction) verified to self-close, self-latch. Facility will install fob entry. Ensure battery back-up.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
No spare pump basket. Provide spare pump basket by Friday, 24th or permit will be suspended.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Pump room floor wet. Keep dry. Clearance not provided around pool equipment. Provide 3 ft. Clearance around all equipment. Original construction.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Some trash in temporary approved restroom. Ensure restrooms are kept clean.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Check valve not ASSE1013. Original construction. If ever replaced, install ASSE 1013 check valve.

View this inspection on the county portal ›

Apr 20, 2021 16 demerits · 3 violations
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Ph recorded at 7.0. CDI- pH adjusted to read at 7.3
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7. Vacccum outlet was loose and not properly secured. CDI- Secured and fastened.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter was not working. CDI- Fixed.

View this inspection on the county portal ›

Apr 29, 2020 4 demerits · 1 violation
Inspector comments: Night swimming NOT approved All 4 and 6 point demerit items in compliance by end of inspection. Issuance of a permit by this department does not negate closure required by Executive Order No. 120 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. Observed one window open wider than 4 inches. CDI: Window limiter placed on window.

View this inspection on the county portal ›

May 10, 2019 0 demerits · 0 violations
Inspector comments: Permit issued. No demerits. No night swimming. All 4 and 6 point demerit items are in compliance.

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 21, 2018 16 demerits · 4 violations
Inspector comments: Permit issued. No Night Swimming. Windows cannot open greater than 4" onto pool deck or have audible alarm. Ensure fireplace has tempered glass. No glass on pool deck. Pool wall has been plastered over since last visit, PDSC form is now accurate for skimmer equalizers-plugged in skimmers and plastered on wall. All previous items addressed.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Buoy rope too long (30'). Maintain width and half of pool, 24'. Operator corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gaps greater than 4" between pillar and gate, considered part of fencing. Maintain gaps less than 4". Pool built '02. Doors/gates swing in toward pool. Gates should swing away from pool. Pool built '02.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter not working at time of inspection. Keep operational. Operator corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored on floor and in pump room. Keep stored separte, off floor or in waterproof containers. Pool built '02.

View this inspection on the county portal ›

Apr 28, 2017 16 demerits · 3 violations
Inspector comments: 6. .2739 PDSC forms shall be updated. Observed pool with less than 2 equalizers and not following state requirements. CDI equalizers permanently plugged during inspection. Facility needs to send in updated PDSC forms. 16. Gates shall be self latching. Observed gate near cafe with a 20 second delay before it latches. Facility must decrease the time frame. Inspection conducted with Brandon Vaughn.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530 Rope must be attached to a US Coast Gaurd approved ring buoy. Observed ring buoy that did show approval. CDI ring buoy changed out.
#22 · Premises: emergency telephone provided −6
.2530 if phone is not visible from pool deck sign shall indicate its location. Observed pool phone without a sign to indicate its location.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
..2518 Flow meter shall be in working order. Observed flow meter that was not operable.

View this inspection on the county portal ›

May 6, 2016 4 demerits · 1 violation
Inspector comments: PERMIT WILL BE ISSUED. POST PERMIT IN PUBLIC VIEW AT THE POOL.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed deck windows to open greater than 4" wide. Pool constructed prior to 2010. Observed foothold self closing spring at 39" on gate.

View this inspection on the county portal ›

Apr 27, 2015 10 demerits · 2 violations
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
equealizer lines were still plugged. CPO removed the plugs during inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Keep furniture at least 6' from pool edge.

View this inspection on the county portal ›

May 1, 2014 8 demerits · 2 violations
Inspector comments: This is not a pool permit. A pool permit will not be issued until a PDSC form has been submitted and approved by the health department. Forms can be found at meckpools.charmeck.org.
#22 · Premises: emergency telephone provided −6
Observed emergency telephone call volumn low. CDI, the volume on emergency telephone increased during inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed less than 3 feet of walkway space between pump equipment inside equipment room. At least 3 feet of clear walkway shall be provided to allow access to equipment.

View this inspection on the county portal ›