0demerits
ARBOR GLEN APARTMENTS
2305 FARMER ST, Charlotte, NC 28208
Seasonal Swimming Pool · NC permit/State ID 2060500986
Latest result0 demerits
Last inspectedMay 29, 2026
Inspections on record8
On record sinceJun 16, 2015
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jun 16, 2015Lower is betterMay 29, 2026
Inspections & violations
May 29, 2026 0 demerits · 0 violations
Inspector comments: Permit issued
No violations observed
No night swimming
Note: Pump does not meet turnover. If clarity issues arise or pump replaced must meet turnover and flow restrictions of pump room.
No violations were recorded for this inspection.
Aug 14, 2025 0 demerits · 0 violations
Inspector comments: All issues from Q-status inspection corrected.
No violations noted during inspection.
Permit issued.
No violations were recorded for this inspection.
Aug 8, 2025 24 demerits · 5 violations
Inspector comments: *Pump does not meet turnover. If clarity issues or replacement occurs, replace with pump that meets turnover and restrictions of system*
ALL INFIELD PLAN REVIEW ITEMS AS STATED 10 skimmers , not nine.
Call Tim at 980-314-1631 when ready for reinspection.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. MAINTAIN pH between 7.2 and 7.8
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Install skimmer per manufacturer specifications and eliminate equalizer line plugs or plug per State requirements. Install plugs inside skimmers to disable equalizer lines
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Third gate which is chained shut must be repaired OR permanently disabled.
#22 · Premises: emergency telephone provided −6
Post phone number of Emergency Phone (980)-207-4205
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Repair flow meter.
Jul 6, 2018 0 demerits · 0 violations
No violations were recorded for this inspection.
Jun 26, 2017 22 demerits · 4 violations
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Observed vacuum line not capped. (IS) issued.
#22 · Premises: emergency telephone provided −6
Observed emergency phone not operational. (IS) issued.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed throw ring with rope length at 60ft; rope cut at 50ft.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed skimmer system missing basket; CDI
Jun 21, 2016 22 demerits · 5 violations
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Pool not circulating and filters showing no pressure
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
7 wiers missing and needs to be at 50% of pool
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
ladder missing one bottom bumper/stopper
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Need new ring buoy and throw rope at 49 feet
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gate not self closing, self latching
Jul 1, 2015 10 demerits · 3 violations
Inspector comments: 5) Observed CPO using new pool log sheet.7) Observed pool floor now smooth.15) Observed new ring buoy with 50 foot throw rope.16) Observed gap under fence corrected.18) Observed proper signage.22) Observed functional emergency phone with correct signage. Emergency phone - Connection not a good connection. Recommend having phone checked.24) Observed functional flow meter installed.25) Observed leak in pump room fixed.Approved PDSC form on file.Issues corrected.Permit will be available within 3 business days. Print copy of permit and post in pool area.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One weir not installed. Corrected by operator.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Fan not working in pump room. Provide functional fan.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Shower off. Corrected by operator.
Jun 16, 2015 42 demerits · 11 violations
Inspector comments: Immediate suspension issued.15)22)The Health Department does not have an approved pool drain safety sheet on file. Please go to Meckpools.charmeck.org to fill out the PDSC form and return to our office. A permit cannot be issued until the form is approved.Contact Will Harrison 704-336-5528 for reinspection when issues have been corrected.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No place on form for Main Drain checks. Check daily Cl, pH, main drains and at least weekly cyanuric acid and total alkalinity.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Clumps of mortar on pool floor from coping repair. Remove mortar and make pool floor and walls smooth. - Intent item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Most weirs missing. Install functional weir. - Intent item.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
No ring buoy or throw rope. Provide US Coast Guard approved ring buoy with 50 foot throw rope. Immediate item.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gap under fence at drain > 4". Fence cannot have gaps > 4" under fence.Back gates not self-closing. Make all gates self-closing and self-latching or keep padlocked shut.
#18 · Premises: lifeguards present or warning signs posted −4
Provide signage in at least 1" lettering stating ADULTS SHOULD NOT SWIM ALONE and CHILDREN SHOULD NOT USE THE SWIMMING POOL WITHOUT ADULT SUPERVISION. - intent item.
#22 · Premises: emergency telephone provided −6
Provide phone number for emergency phone and correct dialing instructions for phone. - Immediate item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. Repair or replace.One pressure guage on one of the sand filters not working properly. Repair or replace.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Leak in pump rooom. Fix leak.Fan in pump room unplugged. Provide functional fan for pump room.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Shower not turned on. Provide functional shower.Provide signage directing bathers to shower before entering the pool.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water > 110F. Maintain at 110F or less.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “ARBOR GLEN APARTMENTS” or State ID 2060500986). Inspection type (routine vs. follow-up) is not published in the county's data.