6demerits
HERITAGE GREEN
19055 LONG POND LN, Cornelius, NC 28031
Seasonal Swimming Pool · NC permit/State ID 2060500993
Latest result6 demerits
Last inspectedMay 28, 2026
Inspections on record16
On record sinceApr 3, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Apr 3, 2014Lower is betterMay 28, 2026
Inspections & violations
May 28, 2026 6 demerits · 2 violations
Inspector comments: NO NIGHT SWIMMING.
Permit Restriction: Filtration flow meter must remain operable. VFD installed and must remain operable. Flow required at least 366 gpm to meet turnover. Flow greater than 500 gpm exceeds the main drain flow. Suction Hazard.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
Observed pool ladder > 6” from wall at bottom of ladder.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 8 ft of clear walking space around the pool at all times (>1600 sq. ft).
Maintain 8’ walking space around pool to pool furniture. CDI
May 27, 2026 18 demerits · 4 violations
Inspector comments: No night swimming.
Permit Restriction: Filtration flow meter must remain operable. VFD installed and must remain operable. Flow required at least 366 gpm to meet turnover. Flow greater than 500 gpm exceeds the main drain flow. Suction Hazard.
Permit denied. See attached 4009C Permit Denial.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
Pool ladder bottom protrudes into pool > 6”.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length.
Observed 2 orange ‘Life Buoys’ ring buoys are not USCG approved for pool. Permit denied. Replace with 2 USCG stamped ring buoys.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 8 ft of clear walking space around the pool at all times (>1600 sq. ft). Observed pool furniture within 8’ of pool edge.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Observed emergency phone (push button) took 3 tries to contact 911 operator. Call back to emergency phone did not work. Permit denied. Repair phone to remain operable.
Apr 28, 2025 18 demerits · 4 violations
Inspector comments: -PDSC verified
-Flow meter must read 360 GPM, no greater than 460 GPM due to drain cover restriction.
-No night swimming
-Emergency phone call box on outside of clubhouse is inoperable. CPO to maintain sign on door directing patrons to use emergency phone inside guard room, which operates as required.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
Observed no recordings in chemical log book for this season.
CPO adds today’s readings and will continue to update going forward.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris.
Observed leaf litter and small amount of sand at bottom of pool. Ability to visualize pool bottom and drain cover is not
compromised.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
Observed debris inside several skimmer baskets.
CPO emptied and cleaned skimmer baskets.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
Observed one ring buoy rope exceeding 50ft.
CPO cuts rope to 50 ft.
Apr 19, 2024 0 demerits · 0 violations
Inspector comments: NOTE:
- No violations observed and PIC: Lance Ricker present during the time of re-inspection.
No violations were recorded for this inspection.
Apr 17, 2024 18 demerits · 4 violations
Inspector comments: PERMIT RESTRICTIONS:
- Flow meter must read at 360 GPM no greater that 460 GPM due to drain cover restrictions.
- Today flow read at 375 GPM during visit.
NOTE:
- This pool # 500993, permit denied today due to the following items on the inspection sheet.
- All items needs to be repaired/replaced, and ensure it is in good working condition.
- Contact EHS: 704-617-9777 or email for return inspection to obtain the operational permit.
- The pool shall remain closed until permit is issued.
- Return visit fee is $100. Need to be paid through the office: 980-314-1620 prior to inspection.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(b) All suction fittings shall be installed in accordance with the manufacturer's instructions.- Observed 4 missing equalizer covers out of 12 totals. Need replacement.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs.- Observed two missing weirs out of twelves total.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.- Observed 2 missing return line covers. Need replacement.
.2537(10) Diving equipment and pool slides including stairs and railings shall be kept in good working order.- Observed one disrepair stair. In the process of fixing. Keep in good working order.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching.- Observed back gate “Exit only” sign posted. It is magnetic gate, it will come close to magnet when swing open, and depending on direction and way, it may latch completely. And this case it doesn’t latch more than half of the time. It didn’t close completely as it should, left access to the pool. This gate shall be repaired and ensure it works properly in timely manner.
May 1, 2023 0 demerits · 0 violations
Inspector comments: Filters backwashed, check flow at 390GPM.
Emergency phone has been repaired and is working correctly.
NO NIGHT SWIMMING
No violations were recorded for this inspection.
Apr 25, 2023 14 demerits · 3 violations
Inspector comments: Observed pool flow at 340 GPM. Ensure pool flow of minimum 360GPM.
Pool water was cloudy today but floor and main drains were visible. Work on clearing water for re-visit.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions.
Observed missing end caps on ladder. CDI
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(b) Two units of lifesaving equipment (or two lifeguards) must be provided for pools that exceed 3,000 sq. ft. surface area.
Observed one body hook missing. CDI added another body hook.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable.
.2530(f) Pool telephone shall be capable of directly dialing 911 or another emergency notification system.
Observed emergency phone did not work and could not dial out to 911. Permit Denied. Once phone is repaired, call 980-314-1620 to request re-visit and pay fee.
May 11, 2022 12 demerits · 2 violations
Inspector comments: RESTRICTIONS VERIFIED
> BLUE WHITE FLOW METER OBSERVED AND OBSERVED AT A RATE OF (375 gpm) WITHIN RANGE OF 360-460.
> 33” INLET AND 8.5” OUTLET VERIFIED DURING INSPECTION.
> ALL DRAIN COVERS APPROVED AND MATCHING APPROVED PDSC FORM.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pool PH measuring at 7.0; CDI corrected to 7.2 during inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed throw rope measuring 60ft (needed=50); CDI rope cut to correct length.
Apr 28, 2021 0 demerits · 0 violations
Inspector comments: Taylor Mastin during this inspection.
PDCS forms were resubmitted and verified main drain covers, equalizer covers, and pumps for the filtration and mushroom.
Seasonal permit issued.
No violations were recorded for this inspection.
May 1, 2020 2 demerits · 1 violation
Inspector comments: Night swimming is not permitted.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Mirrors in bathroom are not shatterproof. Mirrors should be shatterproof.
Apr 17, 2019 2 demerits · 1 violation
Inspector comments: CPO Danny Richards was present during the inspection.
Night Swimming is not permitted.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
(.2512) - Provide back flow prevention. - Observed no back flow prevention device on the hose bib's located on the pool deck.
Apr 10, 2018 6 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris in the skimmer baskets. PIC, John cleaned the skimmer baskets out during the inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed water in the equipment room. Advised to keep equipment room dry.
Jun 6, 2017 18 demerits · 6 violations
Inspector comments: 30 day ITS for lack of signage
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed several areas of the pool floor with the plaster peeling off
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Install protective bumpers on the ladders
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed areas of cracking on the pool decking and coping around the pool
#18 · Premises: lifeguards present or warning signs posted −4
Install a pool sign indicating "Adults should not swim alone" and "Children should not use the swimming pool without adult supervision" 1" letters
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Identify pool flow on the pump room piping
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
Install a back-flow preventer on the hose bibb
Jul 7, 2016 8 demerits · 3 violations
Inspector comments: Report received by John Rhodes
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Record cyanuric acid 1 x week
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Natural cross or continuous forced ventilation required
#27 · Equipment room: filter backwash discharged through an air gap −2
2" air gap required on backwash line
Jun 29, 2015 12 demerits · 4 violations
Inspector comments: Report recevied by Quinn Kennedy
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Record main drain check daily
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter not working
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Fan is connected to light switch - keep on at all times for continuous forced ventilation (chemical room). Keep doors locked at all times
#27 · Equipment room: filter backwash discharged through an air gap −2
2" air gap required on the backwash line
Apr 3, 2014 14 demerits · 4 violations
Inspector comments: Observed exterior hosebib to be leaking onto grass outside of fence. Will make return visit to ensure this does not interefere with safe pool operation.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed pool floor to be soiled. CDI-pool vacuumed during inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris in skimmers. Clean.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter not operating properly. Corrected during inspection.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap for backwash pit. CDI-pipe cut and air gap provided.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “HERITAGE GREEN” or State ID 2060500993). Inspection type (routine vs. follow-up) is not published in the county's data.