12demerits
ROZZELLES LANDING
11735 CODDINGTON RIDGE DR, Charlotte, NC 28214
Seasonal Swimming Pool · NC permit/State ID 2060501008
Latest result12 demerits
Last inspectedMay 14, 2026
Inspections on record14
On record sinceJul 24, 2013
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jul 24, 2013Lower is betterMay 14, 2026
Inspections & violations
May 14, 2026 12 demerits · 3 violations
Inspector comments: Night swimming not permitted.
PERMIT RESTRICTION - FLOW METER MUST REMAIN OPERABLE NOT TO EXCEED 96 GPM DUE TO FILTER FLOW RESTRICTION.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8.
Observed pH at 7.9 upon arrival. CPO stated that they added acid when they first got there. -CDI- pH was able to get to 7.8 during the inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions.
Observed 2 ladders without rubber fittings. -CDI- CPO was able to attach the rubber fittings.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times.
Observed several chairs less than 6 feet from the edge of the pool. -CDI- chairs were pushed back to 6 feet.
May 22, 2025 18 demerits · 4 violations
Inspector comments: No night Swimming
Permit restriction - Flow meter must remain operable not to exceed 96 gpm due to filter flow restriction.
Inspection completed with Jeremy
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(d) No Diving markers shall be written in four inch letters or international 6"x6" no diving in red and black on a white background. 2 No diving markers fading 5 out of 12 unreadable. CDI-CPO was able to repaint No Diving Markers.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. Observed ladder near 5ft side of pool measured 9inches from steps to wall.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy below 30FT measured at 50FT. CDI - CPO installed new 5FT rope.
#22 · Premises: emergency telephone provided −6
.2530(f) Pool telephone shall be capable of directly dialing 911 or another emergency notification system. Observed 911 Emergency phone not dialing 911. CDI - CPO replaced wall mounted corded telephone. EHS was able to 911 and verify location/number.
Apr 15, 2024 14 demerits · 4 violations
Inspector comments: No night swimming.
Inspection conducted with CPO Patrick Hurst.
Permit restriction - Flow meter must remain operable not to exceed 96 gpm due to filter flow restriction.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(d) No Diving markers shall be written in four inch letters or international 6"x6" no diving in red and black on a white background. 2 No diving markers starting to fade on pool deck. Still legible but need to be redone in the future.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. 1 pool ladder missing end cap.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Throw rope > 30ft where required. CDI: operator cut rope and corrected to 30ft.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. Observed no documentation of shatterproof mirrors in restrooms.
.2526(m) Keep restrooms and fixtures clean and in good repair. Observed wall damage in men’s and women’s restroom.
May 30, 2023 4 demerits · 1 violation
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmers having accumulated debris in need of cleaning.
.2518(k) Replace missing weirs. Observed two skimmers missing weirs in need of replacing.
Apr 14, 2022 0 demerits · 0 violations
Inspector comments: Two no diving markers were no clearly visible. PO remarked.
No violations were recorded for this inspection.
Jun 10, 2021 8 demerits · 2 violations
Inspector comments: Pressure gauges verified. Cannot exceed 25psi and -6hg
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. pool ladder missing bumpers. replaced during inspection
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
Throw rope exceeded 1.5 times rules. Operator corrected during inspection
Apr 15, 2020 0 demerits · 0 violations
Inspector comments: Due to covid 19 restrictions, no signature required.
No violations were recorded for this inspection.
May 2, 2019 4 demerits · 1 violation
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris.
Apr 20, 2018 18 demerits · 5 violations
#3 · Water quality: pool water pH −6
Observed pH at 8.2 at the start of the inspection. CDI- By the end of the inspection CPO was able to correct pH to 7.6.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
(.2518, .2537) - Observed debris in skimmers. CDI- CPO removed debris.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
(.2517, .2521) - Observed caps missing on both pool ladders. CPO provided caps.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
(.2528, .2537) - Observed a horizontal foot hold on the fence near the pump room, 29 inches from the ground and 25 inches from the next horizontal foot hold. The EHS observed the horizontal bar screwed into the vertical bars of the fence. CDI- CPO removed the horizontal bar which eliminated the foot holds.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
(.2533, .2534, .2537) Observed wall damage and water damage to pump room walls. Repair the damaged walls in the pump room.
NOTE: VGB drain covers and EQ covers expire October 2018.
CPO Jen Mohler was present during the inspection.
Mecklenburg county public permit number: 18-601075
Apr 10, 2017 4 demerits · 2 violations
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Repair wall in pump room. Replace light bulb in light fixture in chemical storage room or replace damaged light fixture.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Repair wall under wall urinal in boys bathroom. WIpe/clean walls throughout in both men and women bathroom.
May 16, 2016 2 demerits · 1 violation
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533 .2534 .2537 Pump room in good repair. Observed wall in need of repair inside pump room from water damage.
Jun 9, 2015 16 demerits · 5 violations
Inspector comments: 8 - General Comment: Skimmer lid not secure. Keep in good repair.
22 - General Comment: Phone sign missing Dr. Corrected during inspection.
Post permit visible on pool deck.
Challenger 2 hp, 2FE, 4 skimmers - 6hpxxx, 2 sdx retro
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladders >6" from pool wall. Maintain 3" to 6" between.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy at 27 ft. Corrected to 30 ft.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some coping damaged. Repair damage.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Light burnt out in chem storage room and no cross ventilation in chem storage. Provide lighting and cross ventilation.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at backwash line to pit. Provide air gap.
Apr 23, 2014 14 demerits · 5 violations
Inspector comments: 20 - Note: Pool lights could not be verified. 22 - General Comment: Observed some static on pool phone. Monitor and replace when required. Permit will be posted online within 3 days. Post permit visible on deck.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed damaged coping at 3 1/2 ft. Keep in good repair.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ladder 8" from pool wall. Maintain 3" to 6".
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter stuck. Keep operational.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed light and fan tied together with no cross vent. Provide continuous ventilation in chem storage room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed some mildew/build-up in toilets and urinal; damage to wall and mildew on wall/ceilings in men's. Keep in good repair.
Jul 24, 2013 2 demerits · 1 violation
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
OBSERVED SEVERAL ENDCAPS MISSING FROM LADDERS / REPLACE
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “ROZZELLES LANDING” or State ID 2060501008). Inspection type (routine vs. follow-up) is not published in the county's data.