Apr 7, 2026 6 demerits · 2 violations
Inspector comments: 2.5 HP MOTOR ON 2 HP CHALLENGER PUMP - IMPELLER SAME FOR 2.5 AND 2 HP PUMPS - NO SUCTION HAZARD. VERIFY AS CHALLENGER PUMP WITH HP.
2.5 HP motor on 2 HP challenger pump confirmed.
Night Swimming is Not Permitted
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed all skimmers with floating debris. Clear skimmers.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521(b) Ladders shall have slip-resistant tread. Observed missing black slip resistant tread on the middle step ladder. Repair/replace tread. -REPEAT-
Apr 2, 2025 6 demerits · 2 violations
Inspector comments: NOTE:
- Observed a chemical test kit. The DPD Reagent #2 is expired 6/2024. Obtain new chemical reagent.
- CPO: Mr. Donald Moore and Manager: Ms. Breata Smith present during inspection
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace damaged skimmer lid.- Observed 1 out 5 broken skimmer lid. Replacement needed. Keep all skimmer lids in good repair.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521(b) Ladders shall have slip-resistant tread.- Observed missing black slip resistant tread on the middle step ladder. Repair/replace needed.
Apr 25, 2024 4 demerits · 1 violation
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed low meter inoperable/stuck. CDI: CPO repaired flow meter.
Apr 18, 2023 0 demerits · 0 violations
Inspector comments: Note: ring buoy showing signs of wearing, rope beginning to fray, EHS discussed replacing before next pool season with CPO. CPO discussed with management.
No night swimming per CPO Donald Moore.
EHS confirmed drain covers, pump, as per PDSC form.
Permit issued.
No violations were recorded for this inspection.
Apr 1, 2022 6 demerits · 2 violations
Inspector comments: No night swimming per CPO Tay Jenkins
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
Observed floating debris in skimmer. CDI
#26 · Equipment room: valves and pipes identified by color codes or labels −2
.2518(d) Piping and valves shall be labeled with color codes or labels.
Observed piping was not labeled.
Apr 15, 2021 8 demerits · 2 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed small amount of debris floating around in pool and collected on pool floor in need of general cleaning.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed pool chairs stored within 6ft of pool edge.
Apr 14, 2020 12 demerits · 3 violations
Inspector comments: Facility has a 2 1/2 horsepower motor on a 2 horsepower pump per operator PDSC form. 2 1/2 HP and 2HP have the same pump curve and impeller. No suction hazard. Pool operator stated that facility will not have night swimming. Pool will be open from dawn to dusk.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed 2 out of the 5 weirs missing. Replaced both weirs during inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed two end caps missing from ladder.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope length > 45ft. Rope was cut to 45ft during inspection.
Apr 3, 2019 8 demerits · 2 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed pool floor having large amounts of debris in need of cleaning.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmer baskets full of debris in need of proper cleaning.
Apr 3, 2018 6 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 2 out of 5 weirs missing. CDI-one replaced.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed bicarb stored on floor of chemical storage room.
Mar 30, 2017 8 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris in the weirs baskets. CDI - removed debris.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck obstruction; Lounge chairs within 6 ft. from the edge of the pool. CDI - relocated the longe chairs.
Apr 12, 2016 4 demerits · 2 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed missing endcaps on ladder. Replace.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Repair fans in pump and chemical room.
May 14, 2015 4 demerits · 2 violations
Inspector comments: Pool is in the process of renovating clubhouse and deck outside of pool. Currently there are no restrooms inside clubhouse due to renovation. Porta Johns with hand sinks are available temporarily until renovation is completed. Gate entrance has been relocated on other side of pool. Gate met height requirements. Renovation will be completed within 3 weeks. Pool passed pre-permit inspection and permit will be posted online within 3 days at meckpools@charmeck.org.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Replace the one missing endcap on ladder closest to exit of pool.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Replace shower head on shower. Observed with low pressure due to a leaking pipe inside pump room.
Apr 22, 2014 4 demerits · 1 violation
Inspector comments: very nice job!
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed staining on the pool floor by each of the returns.