6demerits
MCINTYRE
9120 COREY COMMONS AV, Charlotte, NC 28216
Seasonal Swimming Pool · NC permit/State ID 2060501015
Latest result6 demerits
Last inspectedApr 21, 2026
Inspections on record13
On record sinceJun 24, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jun 24, 2014Lower is betterApr 21, 2026
Inspections & violations
Apr 21, 2026 6 demerits · 2 violations
Inspector comments: No night swimming.
Permit issued.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris.
Observed accumulation of debris at the bottom of the pool. -CDI- CPO started cleaning the bottom of the pool during the inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions.
Observed missing rubber fixtures on one of the ladders. Replace necessary components.
Apr 9, 2025 16 demerits · 4 violations
Inspector comments: No night swimming
Permit issued
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed debris and pieces of wood along pool floors.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. 7 out 10 weirs missing, they were replaced during inspections.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed 2 base plates for hand rails and 2 base plates for ladders not secured.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed water leaking from pipe connected to pump system.
Apr 18, 2024 20 demerits · 4 violations
Inspector comments: Pool is not permitted for night swimming. Permit issued.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Observed 3 equalizer covers not in place. CDI: CPO found them in supply closet and stated that "the lifeguards stored them there through the winter". Equalizer covers were secured in place and field review matched PDSC form.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed vacuum cover missing. CDI: CPO secured a vacuum cover in place.
#22 · Premises: emergency telephone provided −6
Observed no address or phone number information listed at emergency phone. CDI: information is posted and legible.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed leak occurring at pump. May need repair before next pool season.
Apr 27, 2023 32 demerits · 9 violations
Inspector comments: field confirmed the following items: new pump installed - EQ750, 7.5 hp, Blue White flow meter installed per mfg instructions, operable and read 350 gpm, main drain/skimmer/return pipes are 6" at the floor, 2 Aquastar WAV18W drain covers, 10 Aquastar 6HP EQ line covers, 3 Pentair TR140C filters, 20 returns, 10 skimmers
#2 · Water quality: disinfectant residual provided by −6
chlorine level corrected to 3ppm during inspection
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
keep main drains/pool floor free of debris
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
replaced 5 missing weirs during inspection
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
handrails tightened during inspection
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
rope length corrected to 50' on both ropes; one rope replaced that broke and recommend replacement of other rope
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
extra pump strainer basket needed; fix water leak @ city water line/pipe fitting
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
equipment room floor wet due to water leak
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
mirrors to be of shatterproof construction; water fountain needs repair
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
backflow preventer required on hose bibs
Apr 28, 2022 24 demerits · 5 violations
#1 · Water quality: water clear enough to clearly see bottom of pool and pool drain −6
.2535(2) Main drains must be clearly visible from the pool deck. Observed debris on main drain. CDI: CPO cleaned.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed debris and pollen on water surface. CDI: CPO cleaned.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed four missing weirs and one jammed/stuck weir. CDI: CPO replaced/repaired.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris and pollen in skimmer baskets. CDI: CPO cleaned.
#22 · Premises: emergency telephone provided −6
.2530(f) Provide signage with location of emergency phone if not visible from all areas inside pool enclosure. Observed no signage for location of emergency phone(located in pool office/concessions). CDI: CPO provided and posted signage.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter non-operational/stuck. CDI: CPO repaired.
Apr 13, 2021 20 demerits · 4 violations
Inspector comments: Gary Martin present during inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed leaf debris in both skimmer baskets as well as in pool itself.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Observed 2 ropes, one for each of the 2 buoys. Required length for each is 50 feet. One measured 47 feet 6 inches, the other measured 51 feet. Each corrected by CPO to measure 50 feet.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Observed chip on the edge of the pool deck near the 5 ft area in the back corner. CPO is filling in to grade.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed posted pool telephone number did not match the number supplied by 911. When calling back the number supplied by 911 operator, the phone rang and could be answered from the pool deck. CPO corrected signage by removing incorrect phone number and inserting correct number: 980-299-1679.
Jun 9, 2020 0 demerits · 0 violations
Inspector comments: Due to Covid 19 restrictions, no signature required.
No violations were recorded for this inspection.
May 16, 2019 12 demerits · 4 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Keep baskets free of debris
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Crack in pool deck filled during inspection-several cover anchors tightened down during inspection
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Lights not working, fan not working
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Soap should be provided, mirrors to be of shatter-resistant construction
May 10, 2018 6 demerits · 1 violation
Inspector comments: NO POINTS WERE TAKEN FOR THE FOLLOWING:
#8 - .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed one skimmer not pulling as hard as other skimmers where basket was floating up and debris was collecting under skimmer basket. CDI: Operator adjusted main drain valve.
PDSC information verified. No night swimming.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Observed throw rope to be 46 feet when 50 feet is required. CDI: Operator installed new rope to ring buoy measuring 50 feet.
Jun 26, 2017 4 demerits · 1 violation
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter inoperable. CDI-flow meter was repaired at time of inspection
Jun 15, 2016 10 demerits · 4 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Replace cap on base of ladder.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Return line was missing fitting. Missing fitting placed on return line at time of inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Repair light in pump room.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Provide back flow prevention device on hose bib on pool deck.
Jun 10, 2015 20 demerits · 6 violations
#2 · Water quality: disinfectant residual provided by −6
Chlorine observed at .9 ppm on arrival. Corrected to 2.0 pp by end of inspection. Maintain chlorine at min. 1.0.
#10 · Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints −2
One safety rope float is badly damagedm, needs replacing ASAP.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
One ladder missing both end caps, another ladder missing one end cap. Have safety end caps installed on ladders.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Return line at steps missing its fitting. Have fitting with eyelid installed.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter does not function, needs repair or replacing.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
General Comment: 7) Coping at edge of deep end of pool has 1 to 2 ft section of badly cracked and damaged concrete, needs repair by next pool season.
Jun 24, 2014 20 demerits · 4 violations
#3 · Water quality: pool water pH −6
Observed an pH of 8 upon arrival. Acid added by lifeguard and retested. Current pH is 7.5. Maintain between 7.3-7.8.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed one eyeball missing on an inlet today. Replaced during inspection.
#22 · Premises: emergency telephone provided −6
Observed no sign directing users to the emergency phone. Sign posted today that is visible from all points on the pool deck.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed. the flow meter not working today.