‹ Back to search

24demerits

OLD STONE CROSSING

16516 SILVERSWORD DR, Charlotte, NC 28213
Seasonal Swimming Pool · NC permit/State ID 2060501018
Latest result24 demerits
Last inspectedApr 15, 2026
Inspections on record13
On record sinceJun 26, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01224 Jun 26, 2014: 10Jun 17, 2015: 4Apr 27, 2016: 14Apr 13, 2017: 16Apr 25, 2018: 4May 22, 2019: 0Apr 28, 2020: 4Apr 23, 2021: 8May 3, 2022: 6May 10, 2023: 4Apr 12, 2024: 4Apr 14, 2025: 4Apr 15, 2026: 24
Jun 26, 2014Lower is betterApr 15, 2026

Inspections & violations

Apr 15, 2026 24 demerits · 6 violations
Inspector comments: EHS was unable to observe restroom and shower facilities at time of inspection due to locked clubhouse facility. EHS will return at a later date to verify access. EHS received photographic evidence and verification of like for like impeller used for pool pump motor repair. No night swimming.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed leaf litter and debris on surface of pool.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed one (1) of four skimmers with no weir.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Initially observed ring buoy rope at greater than 50 ft. CDI - CPO measured rope, cut to the permitted length of 38 ft, and attached to ring buoy.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. .2530(c) Provide "Adults should not swim alone." in 1" lettering. Observed posted pool rules signage with required language; however lettering was observed at less than 1” in height. CDI - CPO provided rules signage with proper language and lettering height and affixed to interior fencing via zip ties.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(h) Provide approved pump in good repair. Observed approved pump installed within pump room; however, during inspection and assessment of pump and motor, pool motor failed and pump became non functional. CDI - CPO contacted repair personnel who replaced impeller with verified like for like impeller (serial number N204040230 3.0 HP)
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(a) Provide restrooms at all pools except for hotels, motels, condominiums and apartments where pool use is restricted to guests and residents. .2526(h) Shower(s) shall be provided. EHS and CPO were unable to access facility showers and restrooms due to pool clubhouse door being locked and inaccessible at time of inspection.

View this inspection on the county portal ›

Apr 14, 2025 4 demerits · 1 violation
Inspector comments: No night swimming.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed leaf litter and debris on floor of pool.

View this inspection on the county portal ›

Apr 12, 2024 4 demerits · 1 violation
Inspector comments: PDSC information verified
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed leaf litter and debris on floor of pool.

View this inspection on the county portal ›

May 10, 2023 4 demerits · 1 violation
Inspector comments: Permit issued today. No night swimming requested.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a)(2) Footholds shall not provide a means of entering pool from outside. Observed two electrical boxes providing footholds neat entry gate. Remove foothold using one of the means discussed during inspection. -4-

View this inspection on the county portal ›

May 3, 2022 6 demerits · 1 violation
Inspector comments: No night swimming.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope for ring buoy was 50Ft. CDI: Rope cut to meet required 38Ft.

View this inspection on the county portal ›

Apr 23, 2021 8 demerits · 2 violations
Inspector comments: No night swimming.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. .2530(c) Provide "Adults should not swim alone." in 1" lettering. .2530(c) All pool signage shall be visible upon entrance to the pool and permanently affixed. Observed no signage with the above warnings. CDI: Sign provided and permanently affixed.
#19 · Premises: signs prohibit glass containers or pets in pool area −4
.2530(d) Provide a sign prohibiting pets and glass containers in the pool area. Observed no signage prohibiting pets and glass. CDI: Sign provided and permanently affixed.

View this inspection on the county portal ›

Apr 28, 2020 4 demerits · 1 violation
#20 · Premises: caution signs posted at hot water spas −4
.2532(15) Provide Caution sign in 1/2" lettering 1/2" in height according to Rule .2532(15). - No sign observed, sign was provided. Taylor Mastin was present during inspection.

View this inspection on the county portal ›

May 22, 2019 0 demerits · 0 violations
Inspector comments: John Rhodes present during inspection. No violations observed today. No night swimming allowed.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 25, 2018 4 demerits · 1 violation
Inspector comments: Ashton Williams was present during the inspection. Equilizer covers and Main drain coveres expire October 2018.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed gate leading to splash pad was not self-closing when gate was not opened wide (about 12 inches). CDI - the hindge spring was adjusted during the inspection so the gate was self-closing. The self closing hindge spring will need replacing before the end of the season. .2537(b) All gates and doors shall be self-closing, self-latching.

View this inspection on the county portal ›

Apr 13, 2017 16 demerits · 4 violations
#3 · Water quality: pool water pH −6
Observed the pH at 7.0 Corected during inspection to 7.3
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed dirt and debris on the floor of the pool. Corrected during inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 2 weirs missings. Corrected during inspection. Weirs were replaced.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed one loose ladder. Corrected during inspection.

View this inspection on the county portal ›

Apr 27, 2016 14 demerits · 4 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
observed unsecured weir in skimmer. CDI
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
observed missing treads on pool ladder steps.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
observed openings in pool fence > 4"observed door opening into pool enclosure that is not self-closing, self-latching, and audible alarm not working. CDI- HOA member came and activated chime feature on alarm system.East pool gate entrance remains locked at all times per CPO.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
observed stuck flow meter - cdi

View this inspection on the county portal ›

Jun 17, 2015 4 demerits · 1 violation
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed the flow meter was not working.**Erin Smith was present during the inspection.

View this inspection on the county portal ›

Jun 26, 2014 10 demerits · 3 violations
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed one missing inlet cover. Replace missing cover.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed no sight glass on back wash line. Flow meter at ceiling appears to be stuck. Install a sight glass and repair the flow meter.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed light in chemical room not functioning. Repair the light. Observed minor water leak at one pump. Keep pump room dry.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “OLD STONE CROSSING” or State ID 2060501018). Inspection type (routine vs. follow-up) is not published in the county's data.