CAMDEN SOUTH END

1205 S. TRYON ST, Charlotte, NC 28203
Seasonal Swimming Pool · NC permit/State ID 2060501025
Latest result0 demerits
Last inspectedApr 2, 2026
Inspections on record14
On record sinceJun 26, 2013

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01020 Jun 26, 2013: 6Apr 1, 2014: 10Apr 13, 2015: 4Apr 4, 2016: 4Apr 13, 2017: 0May 31, 2018: 0May 1, 2019: 4May 6, 2020: 4May 10, 2021: 6May 13, 2022: 10Apr 4, 2023: 12Apr 15, 2024: 20Apr 1, 2025: 4Apr 2, 2026: 0
Jun 26, 2013Lower is betterApr 2, 2026

Inspections & violations

Apr 2, 2026 0 demerits · 0 violations
Inspector comments: No violations were observed during the inspection. Permit Restriction - Flow meter must remain operable. Flow must be between 69 gpm to 80 gpm to meet turnover and flow restriction of number of returns. Flow greater than 170 gpm exceeds drain covers. Suction Hazard.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 1, 2025 4 demerits · 1 violation
Inspector comments: Night swimming prohibited Verified permit restriction: flow was 80 gpm on flow meter Drain covers and pump verified during inspection Permit issued.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. 1 weir missing. Replace missing weir.

View this inspection on the county portal ›

Apr 15, 2024 20 demerits · 5 violations
Inspector comments: CPO, Pete McKenzie present during the inspection. Night swimming prohibited. Verified: Permit Restriction - Flow meter must remain operable. Flow shall be set at 69 gpm to 80 gpm to meet turnover and flow restriction of number of returns. New Pump Pentair Intelliflo3 011077, 3 hp pump. (2) Aquastar A10RCFRxxx VGBA-2017 drain covers. FlowVis flow meter installed reading above permit flow restriction (same as submitted picture). (1) Pentair TR100 C filter 4 returns 3 skimmers Main drain, skimmer and return line all 2” pipe through the floor of the pump room. EQ lines are plugged. Permit issued.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Debris in skimmers. CDI - CPO cleaned.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy was too long, CDI - CPO shorten the rope to required length of 32’
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. Window’s in the community room open fully. CDI - CPO added screws to prevent opening more than 4”.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Lounge chairs obstructing clearance around the deck at less than 6’. CDI - CPO relocated chairs
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
.2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. Observed hose bib on the pool deck without a backflow preventer. Provide.

View this inspection on the county portal ›

Apr 4, 2023 12 demerits · 3 violations
Inspector comments: NIGHT SWIMMING NOT PERMITTED. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Observed debris in all skimmers. - CDI: CPO cleaned skimmers during inspection. Ensure frequent cleaning to prevent debris buildup. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. - Ring buoy rope length less measured at 36 ft but should be 32 ft. - CDI - CPO corrected rope length.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. - Observed pH around 7.0 at beginning of inspection. - CDI - CPO added water to pool and brought pH up to 7.2 by end of inspection.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Weekly checks for cyanuric acid and total alkalinity missing frequently. - CDI - CPO completed both required checks. Ensure weekly checks completed moving forward.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. - Ladder very loose. Ladder can be picked up out of the deck with ground wire visible. Secure ladder in pool deck.

View this inspection on the county portal ›

May 13, 2022 10 demerits · 3 violations
Inspector comments: NIGHT SWIMMING NOT PERMITTED
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Skimmer baskets had debris, CDI- Debris discarded.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Ladder very loose, CDI- Tightened during inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Chairs obstructed 6 feet deck clearance. CDI- Chairs moved.

View this inspection on the county portal ›

May 10, 2021 6 demerits · 1 violation
Inspector comments: Verified equalizers have been plugged according to new PDSC approval.
#22 · Premises: emergency telephone provided −6
Emergency Telephone was not properly functioning during inspection, repaired during inspection.

View this inspection on the county portal ›

May 6, 2020 4 demerits · 1 violation
Inspector comments: “Due to COVid19 and public health responsibility, safe distancing and minimizing point of contact, inspection will not be signed as agreement.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed chairs within 6 ft of pool edge. CDI- removed

View this inspection on the county portal ›

May 1, 2019 4 demerits · 1 violation
Inspector comments: Facility does do night swimming. Pool operator turned on pool lights. Schedule visit for night swimming with Kiana Chrisp at 704-621-1458
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed a deck clearance of 4 ft around some pool furniture. CDI- Operator corrected.

View this inspection on the county portal ›

May 31, 2018 0 demerits · 0 violations

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 13, 2017 0 demerits · 0 violations
Inspector comments: No violations. Pre-permit inspection.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 4, 2016 4 demerits · 1 violation
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed fence height to be 34inch between foot holds. Pool constructed in 2003. If fencing is replaced, it must comply with 2010 standards.

View this inspection on the county portal ›

Apr 13, 2015 4 demerits · 2 violations
Inspector comments: Permit will be available online within 3 business days. Go to Meckpools.Charmeck.org to print permit and post in pool area.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Handrail loose. Maintain secure and in good condition.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water 113.5F. Maintain at 110F or less.

View this inspection on the county portal ›

Apr 1, 2014 10 demerits · 3 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Debris in pool
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
One loose ladder
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Missing one inlet fitting

View this inspection on the county portal ›

Jun 26, 2013 6 demerits · 2 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Tighten up ladder. Observed loose hand rail
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Maintain at least 6FT deck clearance around pool. Observed <6FT.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “CAMDEN SOUTH END” or State ID 2060501025). Inspection type (routine vs. follow-up) is not published in the county's data.