‹ Back to search

6demerits

HUNTINGTON FOREST HOA SWIM CLUB

10630 HUNTINGTON MEADOW LN, Charlotte, NC 28273
Seasonal Swimming Pool · NC permit/State ID 2060501028
Latest result6 demerits
Last inspectedApr 24, 2026
Inspections on record14
On record sinceJun 25, 2013

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0918 Jun 25, 2013: 8Jun 4, 2014: 6May 5, 2015: 10May 20, 2016: 16May 11, 2017: 8May 18, 2018: 12Apr 18, 2019: 18May 12, 2020: 4May 25, 2021: 0Apr 12, 2022: 6May 22, 2023: 6May 23, 2024: 0May 15, 2025: 0Apr 24, 2026: 6
Jun 25, 2013Lower is betterApr 24, 2026

Inspections & violations

Apr 24, 2026 6 demerits · 1 violation
Inspector comments: Notes: Impeller verified by aquatech EQ750 - model number on placard indicates a different EQ pump - verified by impeller. Model placard shows EQKT1000 Inspection completed with Mike Sudol
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Buoy rope longer than 50 ft. CDI - CPO cut rope to proper length.

View this inspection on the county portal ›

May 15, 2025 0 demerits · 0 violations
Inspector comments: No night swimming.

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 23, 2024 0 demerits · 0 violations
Inspector comments: Plant pot and trash can next to 48” fence between baby pool and main pool. CPO moved items away from fence. Depth markers 37’ apart at handrail. Depth marker was plastered over and excess plaster had not been removed. CPO removed plaster covering depth marker during inspection. Inspection conducted with Mike Sudol.

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 22, 2023 6 demerits · 1 violation
Inspector comments: No night swimming at this time. Pool will close around 8:30pm. Additional night swimming will have to be conducted in order to approve night swimming. Impeller verfied by EHS to be EQ750 - model number on placard indicated a different EQ Pump - verified by impeller. This is accepted and approved due to notes in field book confirming that information.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope greater than required 50ft. CDI: shortened to 50ft during inspection.

View this inspection on the county portal ›

Apr 12, 2022 6 demerits · 2 violations
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gate to enter pool area was not self latching, repaired by operator during inspection
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
damage to chemical storage area observed

View this inspection on the county portal ›

May 25, 2021 0 demerits · 0 violations
Inspector comments: No violations noted during inspection

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 12, 2020 4 demerits · 1 violation
Inspector comments: Night swimming has not been permitted. Issuance of a permit by this department does not negate closure required by Executive Order No. 120 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed cleaning needed to the pool and equilizer lines. The equilizer lines were cleaned today during the inspection. Pool still needs cleaning. The main drains and floor is easily visible.

View this inspection on the county portal ›

Apr 18, 2019 18 demerits · 4 violations
Inspector comments: Per PDSC forms pump listed as Pentair EQ 750. Pump model on data plate Pentair EQKT 1000 / 340606. Per note listed on last seasons inspection, in field review completed. The findings and approval are as follows: Pump data plate is Pentair EQKT1000. Motor is 7.5 HP. Pump was broken down and impellar inspected. Part # on impellar is 350029. Pentair document indicates 350029 is compatible with 7.5 HP pump. During inspection confirmed pump model, main drains covers Aquastar 1216xxx; and equalizer covers Aquastar 4 HP. Also confirmed pipe diameter for drains (6", 6", 4") skimmers, and return; Filter TR140C (3) GENERAL COMMENT: .2537(2) Decks shall be kept in good repair. Pool decking at ladder on side closest to wading pool damaged. Repair. Ensure permit remains visible at all times. Night swimming is not permitted at this pool.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Initial testing of pH found to be at 7.0. CDI- CPO AJ was able to correct. pH at 7.2 when tested after correction.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Ladder on the side closest to wading pool loose. CDI- CPO repaired.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Both ropes attached to both ring buoys greater than the required 50Ft. CDI- CPO corrected both.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010). Enclosed electrical outlet boxes and supports around perimeter of fencing of the pool creating foot holds and decreasing required spacing of 45" for pool installed pre-2010. Provide sheathing or method to inhibit foot hold.

View this inspection on the county portal ›

May 18, 2018 12 demerits · 3 violations
Inspector comments: Pump data plate is Pentair EQKT1000. Motor is 7.5 HP. Pump was broken down and impellar inspected. Part # on impellar is 350029. Pentair document indicates 350029 is compatible with 7.5 HP pump. During inspection confirmed pump model, main drains covers Aquastar 1216xxx; and equalizer covers Aquastar 4 HP. Also confirmed pipe diameter for drains (6", 6", 4") skimmers, and return; Filter TR140C (3)
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Keep pool walls clean. Observed residue collecting on walls. CDI-Cleaning in progress during inspection
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Pool requires two sets of safety buoys and hooks. One set each observed within fence of pool. Second set in wading pool enclosure. One rope length measured 60'. CDI-= rope cut to 50'. Two sets of equipment moved to pool enclosure.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Standing water in pump room. Rain during inspection.

View this inspection on the county portal ›

May 11, 2017 8 demerits · 2 violations
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Ensure that all vacuum ports in pool have closures or plugged when not in use. Corrected during inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ensure that all ladders and handrails are tight and secure. Check frequently.

View this inspection on the county portal ›

May 20, 2016 16 demerits · 5 violations
Inspector comments: Note: per CPO DJ, camera used on 3 suspected skimmer line blockages& no obstructions found. ** Equalize pull on skimmers by use of "turtles", etc. Pool permit can be issued once 3rd PDSC form is approved. 5/12/16 frorm still indicated 6HP equalizer covers (not 4HP).
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some soil on pool wall tiles. Some algae on pool walls. Debris/ sediment on pool floor. ** Clean walls. Pool being vacuumed while EHS on-site.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Row of lounge chairs ~6' from pool edge. ** Maintain at least 8' of clear walking space.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter float stuck. ** Corrected during inspection.
#27 · Equipment room: filter backwash discharged through an air gap −2
1 (of 3) backwash lines extends down into sump. ** Provide complete air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
- Clean lavatories& urinal in restrooms (sediment/ soil from floor tile work). - Provide soap & toilet paper in both restrooms. - Install missing shower grate in men's restroom.

View this inspection on the county portal ›

May 5, 2015 10 demerits · 3 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed several weirs missing- operator replaced during inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed no hand rail in place. Operator placed during inspeciton.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed vacuum wall fitting not in place. Operator placed threaded cover on vacuum line.

View this inspection on the county portal ›

Jun 4, 2014 6 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Replace missing weir in skimmer basket. Swimming pool is missing four weirs in skimmer basket out of 10 skimmer baskets.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Repair ventilaltion(fan) in pump and chemical room.General Comment: Shower before entering pool posted at pool at time of inspection.

View this inspection on the county portal ›

Jun 25, 2013 8 demerits · 2 violations
Inspector comments: Pool permits must be posted at the pool. Go to meckpools.charmeck.org to access permit.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Four of ten weirs are missing, three of ten baskets are badly damaged, and three of then baskets in skimmers are missing. Replace/ repair all.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meters are damaged/ not operating, and there is no sight glass on back wash line. Provide sight glass, replace/ repair flow meters.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “HUNTINGTON FOREST HOA SWIM CLUB” or State ID 2060501028). Inspection type (routine vs. follow-up) is not published in the county's data.