‹ Back to search

0demerits

MONTEITH PARK

15245 WATERFRONT DR, Huntersville, NC 28078
Seasonal Swimming Pool · NC permit/State ID 2060501049
Latest result0 demerits
Last inspectedMay 13, 2026
Inspections on record13
On record sinceApr 22, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01632 Apr 22, 2014: 16May 1, 2015: 8May 23, 2016: 10Jul 13, 2017: 32Apr 25, 2018: 12Apr 22, 2019: 20Apr 29, 2020: 10Apr 15, 2021: 18May 20, 2022: 14May 9, 2023: 16May 8, 2024: 14Apr 2, 2025: 12May 13, 2026: 0
Apr 22, 2014Lower is betterMay 13, 2026

Inspections & violations

May 13, 2026 0 demerits · 0 violations
Inspector comments: Permit restrictions; flow meter to remain operable. Flow not to exceed 380 gpm due to flow restriction. Perimeter fence is not to current standards of 48in (prior 2010) construction. No permit action (gates meet required standards) Slide drain covers expire on 2/16/2029 main drain covers expire 4-21-2031.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 2, 2025 12 demerits · 4 violations
Inspector comments: NO NIGHT SWIMMING PERMIT ISSUED. Filtration pump flow meter observed to measure 300 GPM.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed light debris accumulation on pool surface and pool floor. CDI: CPO began cleaning pool.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Observed ladder that was loose and not secured into pool decking. CDI: CPO secured ladder and tightened screws into decking.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed eyeball return fitting on vacuum line. CDI: CPO secured vacuum line with a protective cover. REPEAT
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(h) Shower(s) shall be provided. Observed showers with insufficient water pressure and not operating properly. Repair.

View this inspection on the county portal ›

May 8, 2024 14 demerits · 3 violations
Inspector comments: Pool open for season. no Nightswimming permit.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Missing vacuum cover port. Pool Operator had a spare one and installed it corrected on site.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Buoy rope greater than 50 feet long. Pool operator cut it to 50 feet.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Chairs, less less than 6 feet from Pool edge. Corrected

View this inspection on the county portal ›

May 9, 2023 16 demerits · 3 violations
Inspector comments: Verified the main drains and pumps. Night swimming is prohibited. Patrick Hurst, CPO present during the inspection. permit issued.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed the ring buoy rope is more than 50’, CDI - CPO shortened the rope to 50’.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. Observed 6 windows that open up to the pool open more than 4”. CDI - Screws were placed to prevent the windows from opening more than 4”
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed only dial instructions with the emergency phone. CDI. - CPO provided address and telephone number at the emergency phone.

View this inspection on the county portal ›

May 20, 2022 14 demerits · 4 violations
Inspector comments: No night swimming permitted.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
3 weirs missing. Replace.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Pool fence should be at least 48" in height measurement from outside of barrier. Observed fence <48" high. Pool was built pre 2010.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Small leak at backflow preventer. Keep pump room dry.
#18 · Premises: lifeguards present or warning signs posted −4
Adults should not swim alone sign not posted. Corrected during inspection.

View this inspection on the county portal ›

Apr 15, 2021 18 demerits · 5 violations
Inspector comments: Night swimming is not permitted.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed pool floor with debris and wall tile with residue. Cleaning during inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmer baskets with debris. Cleaned during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Observed fence < 48 inches high in some areas. Pool built pre 2010. No permit action required.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter stuck. Repaired during inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed pump room floor wet in area where back flow valve was leaking. Pool operator stated that leak will be repaired today.

View this inspection on the county portal ›

Apr 29, 2020 10 demerits · 3 violations
Inspector comments: Night swimming is not permitted.
#18 · Premises: lifeguards present or warning signs posted −4
Throw rope was 6' too long. Corrected during inspection.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
One filter's pressure gage was not operating properly. Corrected during inspection.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
MIrrors in bathroom are not shatterproof. Mirrors should be shatterproof.

View this inspection on the county portal ›

Apr 22, 2019 20 demerits · 5 violations
Inspector comments: Pool is lifeguarded at all times per Swim Club Management.
#22 · Premises: emergency telephone provided −6
Emergency phone sign not posted. Corrected during inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
One ladder is missing the cap cover on one side.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
One body hook was disassembled. Keep two body hooks functional at all times. Corrected during inspection.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Pump did not have an extra strainer basket. Corrected during inspection. Flow meter is stuck. Repair or replace.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
Hose bib does not have a backflow preventer.

View this inspection on the county portal ›

Apr 25, 2018 12 demerits · 4 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed debris on pool floor
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed minor cracking on pool decking and coping
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed a water leak in the pump room
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
Observed no back-flow preventer on the hose-bibb

View this inspection on the county portal ›

Jul 13, 2017 32 demerits · 9 violations
Inspector comments: PDSC form states that waterslide pump is a 10HP Berkeley B3ZPM5 pump. Observed 7.5 HP motor on pump, pump data plate no longer legible. Recommend verifying pump and that motor isn't undersized. Permit posted in office. Post permit such that it is easily visible by pool bathers. Intent to suspend issued. 5) 16) 17)
#3 · Water quality: pool water pH −6
pH 7.0. Maintain between 7.2 and 7.8. Corrected to 7.2.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Only one TA and CYA check for the last month. Check at least daily Cl, pH, main drains and at least weekly. - Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Very little flow in all skimmers. Ensure proper pool turnover and that skimmers function correctly. Some weirs missing. Install functional weirs. Some skimmer baskets damaged. Maintain in good condition.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Some ladders loose and/or missing non-slip treads. Maintain secure and in good condition.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gates < 48" in height. Provide fencing that meets requirement in .2528, including at least 48" high, no gaps > 4", latch height of 54" or use keyfob, and open away from the pool. If new gate is installed gate must have at least 45" between horizontals. - Intent to suspend item. Windows opening onto the pool deck shall be self-closing or child protected or not capable of opening > 4" inches. - Intent to suspend item. Most of fence < 48". Maintain fence at least 48" high.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Deck chairs too close to pool edge. Maintain at least 8 feet clear walkway. - intent to suspend item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Pump motor grounded to wading pool, not to main pool. Corrected by operator.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
One filter leaking. Fix leak. Some chemicals stored in pump room. Store all chemicals in chemical storage room.
#27 · Equipment room: filter backwash discharged through an air gap −2
Provide air gap for backwash.

View this inspection on the county portal ›

May 23, 2016 10 demerits · 3 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed recess ladder and handrail in the slide section loose. Tightened during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Fences constructed prior to May 2010 where the barrier is composed of vertical and horizontal members and the space between vertical members exceeds 1.75 inches, the distance between the tops of the bottom horizontal member and the next higher horizontal member may be less than 45 inches, but shall not be less than 30 inches. Observed first and second horizontal less than 30''.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck obstruction next to slide area. Observed pool lounge chairs within 6' of the edge of the pool deck. Corrected during inspection.

View this inspection on the county portal ›

May 1, 2015 8 demerits · 2 violations
Inspector comments: Mr. Jeff Frey present during inspection.Permit inspection passed. Permit not valid until available online.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed skimmer plug installed, removed. Observed skimmer baskets dirty, cleaned during inspection. Keep skimmers functioning and clean.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed fence foot hold next to body hook near slide pump. For fences constructed prior to May 2010 where the barrier is composed of vertical and horizontal members and the space between verticalmembers exceeds 1.75 inches, the distance between the tops of the bottom horizontal member and the next higher horizontal member may be less than 45 inches, but shall not be less than 30 inches

View this inspection on the county portal ›

Apr 22, 2014 16 demerits · 4 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed debris on pool floor. CDI
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed floating debris in surface skimmers. CDI
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed areas of pool fence < 48" tall.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed cracks in pool deck < 1/8".Observed damaged pool coping.Repair.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “MONTEITH PARK” or State ID 2060501049). Inspection type (routine vs. follow-up) is not published in the county's data.